From version < 61.28 >
edited by Xiaoling
on 2022/06/14 11:57
To version < 61.21 >
edited by Xiaoling
on 2022/06/14 11:54
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -640,9 +640,7 @@
640 640  )))
641 641  
642 642  (((
643 -
644 -
645 -**Example 1**  ~-~-> Configure without ask for uplink (YY=0)
643 +**Example 1** ~-~-> Configure without ask for uplink (YY=0)
646 646  )))
647 647  
648 648  (((
... ... @@ -658,8 +658,6 @@
658 658  )))
659 659  
660 660  (((
661 -
662 -
663 663  So if user want to use downlink command to control to RS485 Alarm, he can use:
664 664  )))
665 665  
... ... @@ -680,7 +680,7 @@
680 680  )))
681 681  
682 682  (((
683 -**Example 2**  ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
679 +**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
684 684  )))
685 685  
686 686  (((
... ... @@ -692,11 +692,11 @@
692 692  )))
693 693  
694 694  (((
695 -(((
696 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:  **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
691 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:
697 697  )))
698 698  
699 -
694 +(((
695 + **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
700 700  )))
701 701  
702 702  (((
... ... @@ -794,8 +794,6 @@
794 794  )))
795 795  
796 796  (((
797 -
798 -
799 799  **Example:**
800 800  )))
801 801  
... ... @@ -817,7 +817,7 @@
817 817  ==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ====
818 818  
819 819  (((
820 -**AT+MBFUN** is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
814 +AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
821 821  )))
822 822  
823 823  (((
... ... @@ -837,20 +837,18 @@
837 837  )))
838 838  
839 839  * (((
840 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2  are not configure (0,0,0). So RS485-LN.
834 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
841 841  )))
842 842  * (((
843 -AT+COMMAND1= 01 03 00 10 00 08,1  ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
837 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
844 844  )))
845 845  * (((
846 -AT+COMMAND2= 01 02 00 40 00 10,1  ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
847 -
848 -
840 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
849 849  )))
850 850  
851 -(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% title="Click and drag to resize" %)​
843 +(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
852 852  
853 -(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %)​
845 +(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
854 854  
855 855  
856 856  
... ... @@ -867,13 +867,16 @@
867 867  
868 868  * (((
869 869  (% style="color:#037691" %)** AT Command:**
862 +)))
870 870  
864 +(% class="box infomessage" %)
865 +(((
866 +(((
871 871  **AT+CMDDLaa=hex(bb cc)*1000**
872 872  )))
869 +)))
873 873  
874 874  (((
875 -
876 -
877 877  **Example:**
878 878  )))
879 879  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved