Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,6 +12,11 @@ 12 12 13 13 14 14 15 + 16 + 17 + 18 + 19 + 15 15 **Table of Contents:** 16 16 17 17 {{toc/}} ... ... @@ -107,7 +107,6 @@ 107 107 * Packet engine up to 256 bytes with CRC 108 108 109 109 110 - 111 111 == 1.3 Features == 112 112 113 113 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -120,7 +120,6 @@ 120 120 * Support Interrupt uplink (Since hardware version v1.2) 121 121 122 122 123 - 124 124 == 1.4 Applications == 125 125 126 126 * Smart Buildings & Home Automation ... ... @@ -131,7 +131,6 @@ 131 131 * Smart Factory 132 132 133 133 134 - 135 135 == 1.5 Firmware Change log == 136 136 137 137 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -363,6 +363,7 @@ 363 363 364 364 365 365 368 + 366 366 === 3.3.3 Configure read commands for each sampling === 367 367 368 368 ((( ... ... @@ -715,7 +715,7 @@ 715 715 * ((( 716 716 (% style="color:#037691" %)**AT Command:** 717 717 718 -**AT+PAYVER: 721 +**AT+PAYVER: **Set PAYVER field = 1 719 719 720 720 721 721 ))) ... ... @@ -752,9 +752,9 @@ 752 752 (% style="color:#037691" %)**AT Command:** 753 753 ))) 754 754 755 -**AT+COMMANDx: 758 +**AT+COMMANDx: **Configure RS485 read command to sensor. 756 756 757 -**AT+DATACUTx: 760 +**AT+DATACUTx: **Configure how to handle return from RS485 devices. 758 758 759 759 760 760 * ((( ... ... @@ -817,7 +817,7 @@ 817 817 ==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ==== 818 818 819 819 ((( 820 -AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 823 +**AT+MBFUN** is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 821 821 ))) 822 822 823 823 ((( ... ... @@ -867,16 +867,13 @@ 867 867 868 868 * ((( 869 869 (% style="color:#037691" %)** AT Command:** 870 -))) 871 871 872 -(% class="box infomessage" %) 873 -((( 874 -((( 875 875 **AT+CMDDLaa=hex(bb cc)*1000** 876 876 ))) 877 -))) 878 878 879 879 ((( 878 + 879 + 880 880 **Example:** 881 881 ))) 882 882 ... ... @@ -901,11 +901,11 @@ 901 901 ))) 902 902 903 903 ((( 904 - 904 +**Example:** 905 905 ))) 906 906 907 907 ((( 908 - 908 +**0xAA 01 00 01** ~-~-> Same as **AT+CMDDL1=1000 ms** 909 909 ))) 910 910 911 911 ... ... @@ -919,6 +919,8 @@ 919 919 920 920 ((( 921 921 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 922 + 923 + 922 922 ))) 923 923 924 924 * ((( ... ... @@ -978,6 +978,8 @@ 978 978 979 979 ((( 980 980 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 983 + 984 + 981 981 ))) 982 982 983 983 * ((( ... ... @@ -1029,35 +1029,35 @@ 1029 1029 ))) 1030 1030 1031 1031 ((( 1032 -Set Baud Rate: 1036 + 1037 + 1038 +* Set Baud Rate 1033 1033 ))) 1034 1034 1035 - 1036 1036 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1037 1037 1038 1038 1039 1039 ((( 1040 -Set UART Parity 1045 +* Set UART Parity 1041 1041 ))) 1042 1042 1043 - 1044 1044 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1045 1045 1046 1046 1047 1047 ((( 1048 -Set STOPBIT 1052 +* Set STOPBIT 1049 1049 ))) 1050 1050 1051 - 1052 1052 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1053 1053 1054 1054 1058 + 1055 1055 * ((( 1056 1056 (% style="color:#037691" %)** Downlink Payload:** 1057 1057 ))) 1058 1058 1059 1059 ((( 1060 -**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1064 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1061 1061 ))) 1062 1062 1063 1063 ((( ... ... @@ -1072,11 +1072,11 @@ 1072 1072 ))) 1073 1073 1074 1074 ((( 1075 -A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1079 +A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1076 1076 ))) 1077 1077 1078 1078 ((( 1079 -A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1083 +A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1080 1080 ))) 1081 1081 1082 1082 ... ... @@ -1130,7 +1130,7 @@ 1130 1130 ))) 1131 1131 1132 1132 ((( 1133 -**Downlink Command:** 1137 +(% style="color:#037691" %)** Downlink Command:** 1134 1134 ))) 1135 1135 1136 1136 ((( ... ... @@ -1189,6 +1189,9 @@ 1189 1189 |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485 1190 1190 |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1191 1191 1196 + 1197 + 1198 + 1192 1192 == 3.8 LEDs == 1193 1193 1194 1194 ... ... @@ -1197,6 +1197,9 @@ 1197 1197 |**PWR**|Always on if there is power 1198 1198 |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1199 1199 1207 + 1208 + 1209 + 1200 1200 = 4. Case Study = 1201 1201 1202 1202 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -1228,38 +1228,24 @@ 1228 1228 1229 1229 == 5.2 Common AT Command Sequence == 1230 1230 1241 + 1231 1231 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1232 1232 1233 1233 If device has not joined network yet: 1234 1234 1235 -(% class="box infomessage" %) 1236 -((( 1237 -**AT+FDR** 1238 -))) 1246 +* (% style="color:#037691" %)**AT+FDR** 1247 +* (% style="color:#037691" %)**AT+NJM=0** 1248 +* (% style="color:#037691" %)**ATZ** 1239 1239 1240 -(% class="box infomessage" %) 1241 1241 ((( 1242 -**AT+NJM=0** 1243 -))) 1251 + 1244 1244 1245 -(% class="box infomessage" %) 1246 -((( 1247 -**ATZ** 1248 -))) 1249 - 1250 - 1251 -((( 1252 1252 If device already joined network: 1253 -))) 1254 1254 1255 -(% class="box infomessage" %) 1256 -((( 1257 -**AT+NJM=0** 1258 -))) 1255 +* (% style="color:#037691" %)**AT+NJM=0** 1256 +* (% style="color:#037691" %)**ATZ** 1259 1259 1260 -(% class="box infomessage" %) 1261 -((( 1262 -**ATZ** 1258 + 1263 1263 ))) 1264 1264 1265 1265 ... ... @@ -1266,25 +1266,25 @@ 1266 1266 === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 1267 1267 1268 1268 1269 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1265 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1270 1270 1271 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 1267 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%) Set to ABP mode 1272 1272 1273 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 1269 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) Set the Adaptive Data Rate Off 1274 1274 1275 -(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 1271 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) Set Data Rate 1276 1276 1277 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1273 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1278 1278 1279 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1275 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1280 1280 1281 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1277 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1282 1282 1283 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1279 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1284 1284 1285 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1281 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1286 1286 1287 -(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1283 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1288 1288 1289 1289 1290 1290 (% style="color:red" %)**Note:** ... ... @@ -1404,6 +1404,7 @@ 1404 1404 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1405 1405 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1406 1406 1403 + 1407 1407 = 9.Packing Info = 1408 1408 1409 1409 ... ... @@ -1420,6 +1420,7 @@ 1420 1420 * Package Size / pcs : 14.5 x 8 x 5 cm 1421 1421 * Weight / pcs : 170g 1422 1422 1420 + 1423 1423 = 10. FCC Caution for RS485LN-US915 = 1424 1424 1425 1425 (((