Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -80,11 +80,13 @@ 80 80 ** Idle: 32mA@12v 81 81 ** 20dB Transmit: 65mA@12v 82 82 83 + 83 83 **Interface for Model:** 84 84 85 85 * RS485 86 86 * Power Input 7~~ 24V DC. 87 87 89 + 88 88 **LoRa Spec:** 89 89 90 90 * Frequency Range: ... ... @@ -108,6 +108,7 @@ 108 108 109 109 110 110 113 + 111 111 == 1.3 Features == 112 112 113 113 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -121,6 +121,7 @@ 121 121 122 122 123 123 127 + 124 124 == 1.4 Applications == 125 125 126 126 * Smart Buildings & Home Automation ... ... @@ -132,6 +132,7 @@ 132 132 133 133 134 134 139 + 135 135 == 1.5 Firmware Change log == 136 136 137 137 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -334,8 +334,6 @@ 334 334 ))) 335 335 336 336 337 - 338 - 339 339 === 3.3.2 Configure sensors === 340 340 341 341 ((( ... ... @@ -361,8 +361,6 @@ 361 361 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 362 362 363 363 364 - 365 - 366 366 === 3.3.3 Configure read commands for each sampling === 367 367 368 368 ((( ... ... @@ -584,7 +584,7 @@ 584 584 585 585 586 586 587 -==== (% style="color:#037691" %) **RS485 Debug Command**(%%) ====588 +==== **(% style="color:#037691" %)RS485 Debug Command**(%%) ==== 588 588 589 589 ((( 590 590 This command is used to configure the RS485 devices; they won’t be used during sampling. ... ... @@ -591,15 +591,15 @@ 591 591 ))) 592 592 593 593 * ((( 594 -(% style="color:#037691" %) **AT Command**595 +**(% style="color:#037691" %)AT Command** 595 595 596 -((( 597 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 597 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 598 + 599 + 598 598 ))) 599 -))) 600 600 601 601 ((( 602 - 603 +m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 603 603 ))) 604 604 605 605 * ((( ... ... @@ -640,9 +640,7 @@ 640 640 ))) 641 641 642 642 ((( 643 - 644 - 645 -**Example 1** ~-~-> Configure without ask for uplink (YY=0) 644 +**Example 1** ~-~-> Configure without ask for uplink (YY=0) 646 646 ))) 647 647 648 648 ((( ... ... @@ -658,8 +658,6 @@ 658 658 ))) 659 659 660 660 ((( 661 - 662 - 663 663 So if user want to use downlink command to control to RS485 Alarm, he can use: 664 664 ))) 665 665 ... ... @@ -680,7 +680,7 @@ 680 680 ))) 681 681 682 682 ((( 683 -**Example 2** 680 +**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 684 684 ))) 685 685 686 686 ((( ... ... @@ -692,11 +692,11 @@ 692 692 ))) 693 693 694 694 ((( 695 -((( 696 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 692 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: 697 697 ))) 698 698 699 - 695 +((( 696 + **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 700 700 ))) 701 701 702 702 ((( ... ... @@ -706,7 +706,7 @@ 706 706 707 707 708 708 709 -==== (% style="color:blue" %) **Set Payload version**(%%)====706 +==== **(% style="color:blue" %)Set Payload version** ==== 710 710 711 711 ((( 712 712 This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. ... ... @@ -713,28 +713,32 @@ 713 713 ))) 714 714 715 715 * ((( 716 -(% style="color:#037691" %)**AT Command:** 713 +**(% style="color:#037691" %)AT Command:** 714 +))) 717 717 718 -**AT+PAYVER: **Set PAYVER field = 1 719 - 720 - 716 +(% class="box infomessage" %) 717 +((( 718 +((( 719 +**AT+PAYVER: Set PAYVER field = 1** 721 721 ))) 721 +))) 722 + 722 722 * ((( 723 -(% style="color:#037691" %) **Downlink Payload:**724 +**(% style="color:#037691" %)Downlink Payload:** 724 724 ))) 725 725 726 726 ((( 727 -**0xAE 01** ~-~-> 728 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 728 728 ))) 729 729 730 730 ((( 731 -**0xAE 0F** ~-~-> 732 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 732 732 ))) 733 733 734 734 735 735 736 736 737 -==== (% style="color:blue" %) **Set RS485 Sampling Commands**(%%)====738 +==== **(% style="color:blue" %)Set RS485 Sampling Commands** ==== 738 738 739 739 ((( 740 740 AT+COMMANDx or AT+DATACUTx ... ... @@ -749,16 +749,18 @@ 749 749 ))) 750 750 751 751 * ((( 752 -(% style="color:#037691" %) **AT Command:**753 +**(% style="color:#037691" %)AT Command:** 753 753 ))) 754 754 755 -**AT+COMMANDx: **Configure RS485 read command to sensor. 756 756 757 -**AT+ DATACUTx:**Configurehowtohandlereturn fromRS485 devices.757 +**AT+COMMANDx: Configure RS485 read command to sensor.** 758 758 759 759 760 +**AT+DATACUTx: Configure how to handle return from RS485 devices.** 761 + 762 + 760 760 * ((( 761 -(% style="color:#037691" %) **Downlink Payload:**764 +**(% style="color:#037691" %)Downlink Payload:** 762 762 ))) 763 763 764 764 ((( ... ... @@ -794,8 +794,6 @@ 794 794 ))) 795 795 796 796 ((( 797 - 798 - 799 799 **Example:** 800 800 ))) 801 801 ... ... @@ -814,7 +814,7 @@ 814 814 815 815 816 816 817 -==== (% style="color:blue" %) **Fast command to handle MODBUS device**(%%)====818 +==== **(% style="color:blue" %)Fast command to handle MODBUS device** ==== 818 818 819 819 ((( 820 820 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. ... ... @@ -853,7 +853,7 @@ 853 853 854 854 855 855 856 -==== (% style="color:blue" %) **RS485 command timeout**(%%)====857 +==== **(% style="color:blue" %)RS485 command timeout** ==== 857 857 858 858 ((( 859 859 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. ... ... @@ -864,7 +864,7 @@ 864 864 ))) 865 865 866 866 * ((( 867 - (% style="color:#037691" %)**868 +**AT Command:** 868 868 ))) 869 869 870 870 (% class="box infomessage" %) ... ... @@ -887,7 +887,7 @@ 887 887 ))) 888 888 889 889 * ((( 890 - (% style="color:#037691" %)**891 +**Downlink Payload:** 891 891 ))) 892 892 893 893 ((( ... ... @@ -909,7 +909,7 @@ 909 909 910 910 911 911 912 -==== (% style="color:blue" %) **Uplink payload mode**(%%)====913 +==== **(% style="color:blue" %)Uplink payload mode** ==== 913 913 914 914 ((( 915 915 Define to use one uplink or multiple uplinks for the sampling. ... ... @@ -920,16 +920,29 @@ 920 920 ))) 921 921 922 922 * ((( 923 - (% style="color:#037691" %)**924 +**AT Command:** 924 924 ))) 925 925 927 +(% class="box infomessage" %) 928 +((( 929 +((( 926 926 **AT+DATAUP=0** 931 +))) 932 +))) 927 927 934 +(% class="box infomessage" %) 935 +((( 936 +((( 928 928 **AT+DATAUP=1** 938 +))) 939 +))) 929 929 941 +((( 942 + 943 +))) 930 930 931 931 * ((( 932 - (% style="color:#037691" %)**946 +**Downlink Payload:** 933 933 ))) 934 934 935 935 ((( ... ... @@ -943,7 +943,7 @@ 943 943 944 944 945 945 946 -==== (% style="color:blue" %) **Manually trigger an Uplink**(%%)====960 +==== **(% style="color:blue" %)Manually trigger an Uplink** ==== 947 947 948 948 ((( 949 949 Ask device to send an uplink immediately. ... ... @@ -950,7 +950,7 @@ 950 950 ))) 951 951 952 952 * ((( 953 - (% style="color:#037691" %)**967 +**AT Command:** 954 954 ))) 955 955 956 956 ((( ... ... @@ -962,7 +962,7 @@ 962 962 ))) 963 963 964 964 * ((( 965 - (% style="color:#037691" %)**979 +**Downlink Payload:** 966 966 ))) 967 967 968 968 ((( ... ... @@ -972,7 +972,7 @@ 972 972 973 973 974 974 975 -==== (% style="color:blue" %)**Clear RS485 Command**(%%)====989 +==== **Clear RS485 Command** ==== 976 976 977 977 ((( 978 978 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. ... ... @@ -979,7 +979,7 @@ 979 979 ))) 980 980 981 981 * ((( 982 - (% style="color:#037691" %)**996 +**AT Command:** 983 983 ))) 984 984 985 985 ((( ... ... @@ -1006,7 +1006,7 @@ 1006 1006 1007 1007 1008 1008 * ((( 1009 - (% style="color:#037691" %)**1023 +**Downlink Payload:** 1010 1010 ))) 1011 1011 1012 1012 ((( ... ... @@ -1016,7 +1016,7 @@ 1016 1016 1017 1017 1018 1018 1019 -==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%)====1033 +==== **Set Serial Communication Parameters** ==== 1020 1020 1021 1021 ((( 1022 1022 Set the Rs485 serial communication parameters: ... ... @@ -1023,7 +1023,7 @@ 1023 1023 ))) 1024 1024 1025 1025 * ((( 1026 - (% style="color:#037691" %)**1040 +**AT Command:** 1027 1027 ))) 1028 1028 1029 1029 ((( ... ... @@ -1030,28 +1030,41 @@ 1030 1030 Set Baud Rate: 1031 1031 ))) 1032 1032 1033 - 1047 +(% class="box infomessage" %) 1048 +((( 1049 +((( 1034 1034 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1051 +))) 1052 +))) 1035 1035 1036 - 1037 1037 ((( 1038 1038 Set UART Parity 1039 1039 ))) 1040 1040 1041 - 1058 +(% class="box infomessage" %) 1059 +((( 1060 +((( 1042 1042 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1062 +))) 1063 +))) 1043 1043 1044 - 1045 1045 ((( 1046 1046 Set STOPBIT 1047 1047 ))) 1048 1048 1049 - 1069 +(% class="box infomessage" %) 1070 +((( 1071 +((( 1050 1050 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1073 +))) 1074 +))) 1051 1051 1076 +((( 1077 + 1078 +))) 1052 1052 1053 1053 * ((( 1054 - (% style="color:#037691" %)**1081 +**Downlink Payload:** 1055 1055 ))) 1056 1056 1057 1057 (((