From version < 61.23 >
edited by Xiaoling
on 2022/06/14 11:54
To version < 61.30 >
edited by Xiaoling
on 2022/06/14 11:58
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -658,6 +658,8 @@
658 658  )))
659 659  
660 660  (((
661 +
662 +
661 661  So if user want to use downlink command to control to RS485 Alarm, he can use:
662 662  )))
663 663  
... ... @@ -678,7 +678,7 @@
678 678  )))
679 679  
680 680  (((
681 -**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
683 +**Example 2**  ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
682 682  )))
683 683  
684 684  (((
... ... @@ -690,11 +690,11 @@
690 690  )))
691 691  
692 692  (((
693 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:
695 +(((
696 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:  **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
694 694  )))
695 695  
696 -(((
697 - **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
699 +
698 698  )))
699 699  
700 700  (((
... ... @@ -792,6 +792,8 @@
792 792  )))
793 793  
794 794  (((
797 +
798 +
795 795  **Example:**
796 796  )))
797 797  
... ... @@ -813,7 +813,7 @@
813 813  ==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ====
814 814  
815 815  (((
816 -AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
820 +**AT+MBFUN** is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
817 817  )))
818 818  
819 819  (((
... ... @@ -833,18 +833,20 @@
833 833  )))
834 834  
835 835  * (((
836 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
840 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2  are not configure (0,0,0). So RS485-LN.
837 837  )))
838 838  * (((
839 -AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
843 +AT+COMMAND1= 01 03 00 10 00 08,1  ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
840 840  )))
841 841  * (((
842 -AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
846 +AT+COMMAND2= 01 02 00 40 00 10,1  ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
847 +
848 +
843 843  )))
844 844  
845 -(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
851 +(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% title="Click and drag to resize" %)​
846 846  
847 -(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
853 +(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %)​
848 848  
849 849  
850 850  
... ... @@ -861,16 +861,13 @@
861 861  
862 862  * (((
863 863  (% style="color:#037691" %)** AT Command:**
864 -)))
865 865  
866 -(% class="box infomessage" %)
867 -(((
868 -(((
869 869  **AT+CMDDLaa=hex(bb cc)*1000**
870 870  )))
871 -)))
872 872  
873 873  (((
875 +
876 +
874 874  **Example:**
875 875  )))
876 876  
... ... @@ -895,11 +895,11 @@
895 895  )))
896 896  
897 897  (((
898 - **Example:**
901 +**Example:**
899 899  )))
900 900  
901 901  (((
902 - 0xAA 01 00 01  ~-~-> Same as **AT+CMDDL1=1000 ms**
905 +**0xAA 01 00 01**  ~-~-> Same as  **AT+CMDDL1=1000 ms**
903 903  )))
904 904  
905 905  
... ... @@ -913,6 +913,8 @@
913 913  
914 914  (((
915 915  The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
919 +
920 +
916 916  )))
917 917  
918 918  * (((
... ... @@ -972,6 +972,8 @@
972 972  
973 973  (((
974 974  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
980 +
981 +
975 975  )))
976 976  
977 977  * (((
... ... @@ -1023,29 +1023,29 @@
1023 1023  )))
1024 1024  
1025 1025  (((
1026 -Set Baud Rate:
1033 +
1034 +
1035 +* Set Baud Rate
1027 1027  )))
1028 1028  
1029 -
1030 1030  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1031 1031  
1032 1032  
1033 1033  (((
1034 -Set UART Parity
1042 +* Set UART Parity
1035 1035  )))
1036 1036  
1037 -
1038 1038  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1039 1039  
1040 1040  
1041 1041  (((
1042 -Set STOPBIT
1049 +* Set STOPBIT
1043 1043  )))
1044 1044  
1045 -
1046 1046  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1047 1047  
1048 1048  
1055 +
1049 1049  * (((
1050 1050  (% style="color:#037691" %)** Downlink Payload:**
1051 1051  )))
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0