From version < 61.21 >
edited by Xiaoling
on 2022/06/14 11:54
To version < 61.26 >
edited by Xiaoling
on 2022/06/14 11:56
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -640,7 +640,9 @@
640 640  )))
641 641  
642 642  (((
643 -**Example 1** ~-~-> Configure without ask for uplink (YY=0)
643 +
644 +
645 +**Example 1**  ~-~-> Configure without ask for uplink (YY=0)
644 644  )))
645 645  
646 646  (((
... ... @@ -656,6 +656,8 @@
656 656  )))
657 657  
658 658  (((
661 +
662 +
659 659  So if user want to use downlink command to control to RS485 Alarm, he can use:
660 660  )))
661 661  
... ... @@ -676,7 +676,7 @@
676 676  )))
677 677  
678 678  (((
679 -**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
683 +**Example 2**  ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
680 680  )))
681 681  
682 682  (((
... ... @@ -688,11 +688,11 @@
688 688  )))
689 689  
690 690  (((
691 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:
695 +(((
696 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:  **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
692 692  )))
693 693  
694 -(((
695 - **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
699 +
696 696  )))
697 697  
698 698  (((
... ... @@ -790,6 +790,8 @@
790 790  )))
791 791  
792 792  (((
797 +
798 +
793 793  **Example:**
794 794  )))
795 795  
... ... @@ -831,13 +831,15 @@
831 831  )))
832 832  
833 833  * (((
834 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
840 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2  are not configure (0,0,0). So RS485-LN.
835 835  )))
836 836  * (((
837 -AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
843 +AT+COMMAND1= 01 03 00 10 00 08,1  ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
838 838  )))
839 839  * (((
840 -AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
846 +AT+COMMAND2= 01 02 00 40 00 10,1  ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
847 +
848 +
841 841  )))
842 842  
843 843  (% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0