96 96  * Packet engine up to 256 bytes with CRC
97 97  
98 98  
99 -
100 100  == 1.3 Features ==
101 101  
102 102  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -109,7 +109,6 @@
109 109  * Support Interrupt uplink (Since hardware version v1.2)
110 110  
111 111  
112 -
113 113  == 1.4 Applications ==
114 114  
115 115  * Smart Buildings & Home Automation
... ... @@ -120,7 +120,6 @@
120 120  * Smart Factory
121 121  
122 122  
123 -
124 124  == 1.5 Firmware Change log ==
125 125  
126 126  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -324,7 +324,6 @@
324 324  
325 325  
326 326  
327 -
328 328  === 3.3.2 Configure sensors ===
329 329  
330 330  (((
... ... @@ -349,6 +349,8 @@
349 349  )))
350 350  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
351 351  
348 +
349 +
352 352  === 3.3.3 Configure read commands for each sampling ===
353 353  
354 354  (((
... ... @@ -372,7 +372,6 @@
372 372  
373 373  After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**.
374 374  
375 -
376 376  Below are examples for the how above AT Commands works.
377 377  
378 378  
... ... @@ -499,6 +499,7 @@
499 499  [[image:1654157178836-407.png]]
500 500  
501 501  
499 +
502 502  === 3.3.5 Uplink on demand ===
503 503  
504 504  Except uplink periodically, RS485-LN is able to uplink on demand. The server send downlink command to RS485-LN and RS485 will uplink data base on the command.
... ... @@ -570,7 +570,7 @@
570 570  
571 571  
572 572  
573 -==== **RS485 Debug Command** ====
571 +==== (% style="color:#037691" %)**RS485 Debug Command**(%%) ====
574 574  
575 575  (((
576 576  This command is used to configure the RS485 devices; they won’t be used during sampling.
... ... @@ -577,15 +577,12 @@
577 577  )))
578 578  
579 579  * (((
580 -**AT Command**
581 -)))
578 +(% style="color:#037691" %)**AT Command**
582 582  
583 -(% class="box infomessage" %)
584 -(((
585 -(((
586 586  **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
581 +
582 +
587 587  )))
588 -)))
589 589  
590 590  (((
591 591  m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
... ... @@ -592,7 +592,7 @@