Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -14,11 +14,70 @@ 14 14 15 15 **Table of Contents:** 16 16 17 -{{toc/}} 18 - 19 - 20 20 (% aria-label="macro:toc widget" contenteditable="false" role="region" tabindex="-1" %) 21 21 ((( 19 +(% class="macro" data-macro="startmacro:toc|-|" data-widget="xwiki-macro" %) 20 +((( 21 +(% class="macro-placeholder hidden" %) 22 +((( 23 +macro:toc 24 +))) 25 + 26 +* [[1.Introduction>>doc:null||anchor="H1.Introduction"]] 27 +** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>doc:null||anchor="H1.1A0WhatisRS485-LNRS485toLoRaWANConverter"]] 28 +** [[1.2 Specifications>>doc:null||anchor="H1.2A0Specifications"]] 29 +** [[1.3 Features>>doc:null||anchor="H1.3Features"]] 30 +** [[1.4 Applications>>doc:null||anchor="H1.4A0Applications"]] 31 +** [[1.5 Firmware Change log>>doc:null||anchor="H1.5A0FirmwareChangelog"]] 32 +** [[1.6 Hardware Change log>>doc:null||anchor="H1.6HardwareChangelog"]] 33 +* [[2. Power ON Device>>doc:null||anchor="H2.PowerONDevice"]] 34 +* [[3. Operation Mode>>doc:null||anchor="H3.A0OperationMode"]] 35 +** [[3.1 How it works?>>doc:null||anchor="H3.1Howitworks3F"]] 36 +** [[3.2 Example to join LoRaWAN network>>doc:null||anchor="H3.2ExampletojoinLoRaWANnetwork"]] 37 +** [[3.3 Configure Commands to read data>>doc:null||anchor="H3.3ConfigureCommandstoreaddata"]] 38 +*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>doc:null||anchor="H3.3.1onfigureUARTsettingsforRS485orTTLcommunication"]] 39 +*** [[3.3.2 Configure sensors>>doc:null||anchor="H3.3.2Configuresensors"]] 40 +*** [[3.3.3 Configure read commands for each sampling>>doc:null||anchor="H3.3.3Configurereadcommandsforeachsampling"]] 41 +*** [[3.3.4 Compose the uplink payload>>doc:null||anchor="H3.3.4Composetheuplinkpayload"]] 42 +*** [[3.3.5 Uplink on demand>>doc:null||anchor="H3.3.5Uplinkondemand"]] 43 +*** [[3.3.6 Uplink on Interrupt>>doc:null||anchor="H3.3.6UplinkonInterrupt"]] 44 +** [[3.4 Uplink Payload>>doc:null||anchor="H3.4UplinkPayload"]] 45 +** [[3.5 Configure RS485-LN via AT or Downlink>>doc:null||anchor="H3.5ConfigureRS485-LNviaATorDownlink"]] 46 +*** [[3.5.1 Common Commands>>doc:null||anchor="H3.5.1CommonCommands"]] 47 +*** [[3.5.2 Sensor related commands>>doc:null||anchor="H3.5.2Sensorrelatedcommands"]] 48 +*** [[3.5.3 Sensor related commands>>doc:null||anchor="H3.5.3A0Sensorrelatedcommands"]] 49 +**** [[RS485 Debug Command>>doc:null||anchor="HRS485DebugCommand"]] 50 +**** [[Set Payload version>>doc:null||anchor="HSetPayloadversion"]] 51 +**** [[Set RS485 Sampling Commands>>doc:null||anchor="HSetRS485SamplingCommands"]] 52 +**** [[Fast command to handle MODBUS device>>doc:null||anchor="HFastcommandtohandleMODBUSdevice"]] 53 +**** [[RS485 command timeout>>doc:null||anchor="HRS485commandtimeout"]] 54 +**** [[Uplink payload mode>>doc:null||anchor="HUplinkpayloadmode"]] 55 +**** [[Manually trigger an Uplink>>doc:null||anchor="HManuallytriggeranUplink"]] 56 +**** [[Clear RS485 Command>>doc:null||anchor="HClearRS485Command"]] 57 +**** [[Set Serial Communication Parameters>>doc:null||anchor="HSetSerialCommunicationParameters"]] 58 +** [[3.6 Listening mode for RS485 network>>doc:null||anchor="H3.6A0ListeningmodeforRS485network"]] 59 +** [[3.7 Buttons>>doc:null||anchor="H3.7Buttons"]] 60 +** [[3.8 LEDs>>doc:null||anchor="H3.8LEDs"]] 61 +* [[4. Case Study>>doc:null||anchor="H4.CaseStudy"]] 62 +* [[5. Use AT Command>>doc:null||anchor="H5.UseATCommand"]] 63 +** [[5.1 Access AT Command>>doc:null||anchor="H5.1AccessATCommand"]] 64 +** [[5.2 Common AT Command Sequence>>doc:null||anchor="H5.2CommonATCommandSequence"]] 65 +*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>doc:null||anchor="H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829"]] 66 +*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>doc:null||anchor="H5.5.2Single-channelABPmode28UsewithLG012FLG0229"]] 67 +* [[6. FAQ>>doc:null||anchor="H6.FAQ"]] 68 +** [[6.1 How to upgrade the image?>>doc:null||anchor="H6.1Howtoupgradetheimage3F"]] 69 +** [[6.2 How to change the LoRa Frequency Bands/Region?>>doc:null||anchor="H6.2HowtochangetheLoRaFrequencyBands2FRegion3F"]] 70 +** [[6.3 How many RS485-Slave can RS485-LN connects?>>doc:null||anchor="H6.3HowmanyRS485-SlavecanRS485-LNconnects3F"]] 71 +** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>doc:null||anchor="H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F"]] 72 +* [[7. Trouble Shooting>>doc:null||anchor="H7.TroubleShooting"]] 73 +** [[7.1 Downlink doesn’t work, how to solve it?>>doc:null||anchor="H7.1Downlinkdoesn2019twork2Chowtosolveit3F"]] 74 +** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>doc:null||anchor="H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F"]] 75 +* [[8. Order Info>>doc:null||anchor="H8.OrderInfo"]] 76 +* [[9.Packing Info>>doc:null||anchor="H9.PackingInfo"]] 77 +* [[10. FCC Caution for RS485LN-US915>>doc:null||anchor="H10.FCCCautionforRS485LN-US915"]] 78 +* [[11. Support>>doc:null||anchor="H11.Support"]] 79 +))) 80 + 22 22 (% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||height="15" role="presentation" title="Click and drag to move" width="15"]] 23 23 ))) 24 24 ... ... @@ -107,7 +107,6 @@ 107 107 * Packet engine up to 256 bytes with CRC 108 108 109 109 110 - 111 111 == 1.3 Features == 112 112 113 113 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -120,7 +120,6 @@ 120 120 * Support Interrupt uplink (Since hardware version v1.2) 121 121 122 122 123 - 124 124 == 1.4 Applications == 125 125 126 126 * Smart Buildings & Home Automation ... ... @@ -131,7 +131,6 @@ 131 131 * Smart Factory 132 132 133 133 134 - 135 135 == 1.5 Firmware Change log == 136 136 137 137 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -333,6 +333,8 @@ 333 333 ))) 334 334 ))) 335 335 392 + 393 + 336 336 === 3.3.2 Configure sensors === 337 337 338 338 ((( ... ... @@ -359,7 +359,6 @@ 359 359 360 360 361 361 362 - 363 363 === 3.3.3 Configure read commands for each sampling === 364 364 365 365 ((( ... ... @@ -699,7 +699,7 @@ 699 699 700 700 701 701 702 -==== (% style="color:blue" %)**Set Payload version**(%%)====759 +==== **Set Payload version** ==== 703 703 704 704 ((( 705 705 This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. ... ... @@ -706,28 +706,32 @@ 706 706 ))) 707 707 708 708 * ((( 709 -(% style="color:#037691" %)**AT Command:** 766 +**AT Command:** 767 +))) 710 710 711 -**AT+PAYVER: **Set PAYVER field = 1 712 - 713 - 769 +(% class="box infomessage" %) 770 +((( 771 +((( 772 +**AT+PAYVER: Set PAYVER field = 1** 714 714 ))) 774 +))) 775 + 715 715 * ((( 716 - (% style="color:#037691" %)**Downlink Payload:**777 +**Downlink Payload:** 717 717 ))) 718 718 719 719 ((( 720 -**0xAE 01** ~-~-> 781 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 721 721 ))) 722 722 723 723 ((( 724 -**0xAE 0F** ~-~-> 785 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 725 725 ))) 726 726 727 727 728 728 729 729 730 -==== (% style="color:blue" %)**Set RS485 Sampling Commands**(%%)====791 +==== **Set RS485 Sampling Commands** ==== 731 731 732 732 ((( 733 733 AT+COMMANDx or AT+DATACUTx ... ... @@ -742,16 +742,29 @@ 742 742 ))) 743 743 744 744 * ((( 745 - (% style="color:#037691" %)**AT Command:**806 +**AT Command:** 746 746 ))) 747 747 748 -**AT+COMMANDx: **Configure RS485 read command to sensor. 809 +(% class="box infomessage" %) 810 +((( 811 +((( 812 +**AT+COMMANDx: Configure RS485 read command to sensor.** 813 +))) 814 +))) 749 749 750 -**AT+DATACUTx: **Configure how to handle return from RS485 devices. 816 +(% class="box infomessage" %) 817 +((( 818 +((( 819 +**AT+DATACUTx: Configure how to handle return from RS485 devices.** 820 +))) 821 +))) 751 751 823 +((( 824 + 825 +))) 752 752 753 753 * ((( 754 - (% style="color:#037691" %)**Downlink Payload:**828 +**Downlink Payload:** 755 755 ))) 756 756 757 757 ((( ... ... @@ -805,7 +805,7 @@ 805 805 806 806 807 807 808 -==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%)====882 +==== **Fast command to handle MODBUS device** ==== 809 809 810 810 ((( 811 811 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. ... ... @@ -844,7 +844,7 @@ 844 844 845 845 846 846 847 -==== (% style="color:blue" %)**RS485 command timeout**(%%)====921 +==== **RS485 command timeout** ==== 848 848 849 849 ((( 850 850 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. ... ... @@ -855,7 +855,7 @@ 855 855 ))) 856 856 857 857 * ((( 858 - (% style="color:#037691" %)**932 +**AT Command:** 859 859 ))) 860 860 861 861 (% class="box infomessage" %) ... ... @@ -878,7 +878,7 @@ 878 878 ))) 879 879 880 880 * ((( 881 - (% style="color:#037691" %)**955 +**Downlink Payload:** 882 882 ))) 883 883 884 884 ((( ... ... @@ -900,7 +900,7 @@ 900 900 901 901 902 902 903 -==== (% style="color:blue" %)**Uplink payload mode**(%%)====977 +==== **Uplink payload mode** ==== 904 904 905 905 ((( 906 906 Define to use one uplink or multiple uplinks for the sampling. ... ... @@ -911,16 +911,29 @@ 911 911 ))) 912 912 913 913 * ((( 914 - (% style="color:#037691" %)**988 +**AT Command:** 915 915 ))) 916 916 991 +(% class="box infomessage" %) 992 +((( 993 +((( 917 917 **AT+DATAUP=0** 995 +))) 996 +))) 918 918 998 +(% class="box infomessage" %) 999 +((( 1000 +((( 919 919 **AT+DATAUP=1** 1002 +))) 1003 +))) 920 920 1005 +((( 1006 + 1007 +))) 921 921 922 922 * ((( 923 - (% style="color:#037691" %)**1010 +**Downlink Payload:** 924 924 ))) 925 925 926 926 ((( ... ... @@ -934,7 +934,7 @@ 934 934 935 935 936 936 937 -==== (% style="color:blue" %)**Manually trigger an Uplink**(%%)====1024 +==== **Manually trigger an Uplink** ==== 938 938 939 939 ((( 940 940 Ask device to send an uplink immediately. ... ... @@ -941,7 +941,7 @@ 941 941 ))) 942 942 943 943 * ((( 944 - (% style="color:#037691" %)**1031 +**AT Command:** 945 945 ))) 946 946 947 947 ((( ... ... @@ -953,7 +953,7 @@ 953 953 ))) 954 954 955 955 * ((( 956 - (% style="color:#037691" %)**1043 +**Downlink Payload:** 957 957 ))) 958 958 959 959 ((( ... ... @@ -963,7 +963,7 @@ 963 963 964 964 965 965 966 -==== (% style="color:blue" %)**Clear RS485 Command**(%%)====1053 +==== **Clear RS485 Command** ==== 967 967 968 968 ((( 969 969 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. ... ... @@ -970,7 +970,7 @@ 970 970 ))) 971 971 972 972 * ((( 973 - (% style="color:#037691" %)**1060 +**AT Command:** 974 974 ))) 975 975 976 976 ((( ... ... @@ -997,7 +997,7 @@ 997 997 998 998 999 999 * ((( 1000 - (% style="color:#037691" %)**1087 +**Downlink Payload:** 1001 1001 ))) 1002 1002 1003 1003 ((( ... ... @@ -1007,7 +1007,7 @@ 1007 1007 1008 1008 1009 1009 1010 -==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%)====1097 +==== **Set Serial Communication Parameters** ==== 1011 1011 1012 1012 ((( 1013 1013 Set the Rs485 serial communication parameters: ... ... @@ -1014,7 +1014,7 @@ 1014 1014 ))) 1015 1015 1016 1016 * ((( 1017 - (% style="color:#037691" %)**1104 +**AT Command:** 1018 1018 ))) 1019 1019 1020 1020 ((( ... ... @@ -1021,28 +1021,41 @@ 1021 1021 Set Baud Rate: 1022 1022 ))) 1023 1023 1024 - 1111 +(% class="box infomessage" %) 1112 +((( 1113 +((( 1025 1025 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1115 +))) 1116 +))) 1026 1026 1027 - 1028 1028 ((( 1029 1029 Set UART Parity 1030 1030 ))) 1031 1031 1032 - 1122 +(% class="box infomessage" %) 1123 +((( 1124 +((( 1033 1033 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1126 +))) 1127 +))) 1034 1034 1035 - 1036 1036 ((( 1037 1037 Set STOPBIT 1038 1038 ))) 1039 1039 1040 - 1133 +(% class="box infomessage" %) 1134 +((( 1135 +((( 1041 1041 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1137 +))) 1138 +))) 1042 1042 1140 +((( 1141 + 1142 +))) 1043 1043 1044 1044 * ((( 1045 - (% style="color:#037691" %)**1145 +**Downlink Payload:** 1046 1046 ))) 1047 1047 1048 1048 (((