From version < 61.19 >
edited by Xiaoling
on 2022/06/14 11:52
To version < 61.6 >
edited by Xiaoling
on 2022/06/14 11:40
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -14,11 +14,70 @@
14 14  
15 15  **Table of Contents:**
16 16  
17 -{{toc/}}
18 -
19 -
20 20  (% aria-label="macro:toc widget" contenteditable="false" role="region" tabindex="-1" %)
21 21  (((
19 +(% class="macro" data-macro="startmacro:toc|-|" data-widget="xwiki-macro" %)
20 +(((
21 +(% class="macro-placeholder hidden" %)
22 +(((
23 +macro:toc
24 +)))
25 +
26 +* [[1.Introduction>>doc:null||anchor="H1.Introduction"]]
27 +** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>doc:null||anchor="H1.1A0WhatisRS485-LNRS485toLoRaWANConverter"]]
28 +** [[1.2 Specifications>>doc:null||anchor="H1.2A0Specifications"]]
29 +** [[1.3 Features>>doc:null||anchor="H1.3Features"]]
30 +** [[1.4 Applications>>doc:null||anchor="H1.4A0Applications"]]
31 +** [[1.5 Firmware Change log>>doc:null||anchor="H1.5A0FirmwareChangelog"]]
32 +** [[1.6 Hardware Change log>>doc:null||anchor="H1.6HardwareChangelog"]]
33 +* [[2. Power ON Device>>doc:null||anchor="H2.PowerONDevice"]]
34 +* [[3. Operation Mode>>doc:null||anchor="H3.A0OperationMode"]]
35 +** [[3.1 How it works?>>doc:null||anchor="H3.1Howitworks3F"]]
36 +** [[3.2 Example to join LoRaWAN network>>doc:null||anchor="H3.2ExampletojoinLoRaWANnetwork"]]
37 +** [[3.3 Configure Commands to read data>>doc:null||anchor="H3.3ConfigureCommandstoreaddata"]]
38 +*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>doc:null||anchor="H3.3.1onfigureUARTsettingsforRS485orTTLcommunication"]]
39 +*** [[3.3.2 Configure sensors>>doc:null||anchor="H3.3.2Configuresensors"]]
40 +*** [[3.3.3 Configure read commands for each sampling>>doc:null||anchor="H3.3.3Configurereadcommandsforeachsampling"]]
41 +*** [[3.3.4 Compose the uplink payload>>doc:null||anchor="H3.3.4Composetheuplinkpayload"]]
42 +*** [[3.3.5 Uplink on demand>>doc:null||anchor="H3.3.5Uplinkondemand"]]
43 +*** [[3.3.6 Uplink on Interrupt>>doc:null||anchor="H3.3.6UplinkonInterrupt"]]
44 +** [[3.4 Uplink Payload>>doc:null||anchor="H3.4UplinkPayload"]]
45 +** [[3.5 Configure RS485-LN via AT or Downlink>>doc:null||anchor="H3.5ConfigureRS485-LNviaATorDownlink"]]
46 +*** [[3.5.1 Common Commands>>doc:null||anchor="H3.5.1CommonCommands"]]
47 +*** [[3.5.2 Sensor related commands>>doc:null||anchor="H3.5.2Sensorrelatedcommands"]]
48 +*** [[3.5.3 Sensor related commands>>doc:null||anchor="H3.5.3A0Sensorrelatedcommands"]]
49 +**** [[RS485 Debug Command>>doc:null||anchor="HRS485DebugCommand"]]
50 +**** [[Set Payload version>>doc:null||anchor="HSetPayloadversion"]]
51 +**** [[Set RS485 Sampling Commands>>doc:null||anchor="HSetRS485SamplingCommands"]]
52 +**** [[Fast command to handle MODBUS device>>doc:null||anchor="HFastcommandtohandleMODBUSdevice"]]
53 +**** [[RS485 command timeout>>doc:null||anchor="HRS485commandtimeout"]]
54 +**** [[Uplink payload mode>>doc:null||anchor="HUplinkpayloadmode"]]
55 +**** [[Manually trigger an Uplink>>doc:null||anchor="HManuallytriggeranUplink"]]
56 +**** [[Clear RS485 Command>>doc:null||anchor="HClearRS485Command"]]
57 +**** [[Set Serial Communication Parameters>>doc:null||anchor="HSetSerialCommunicationParameters"]]
58 +** [[3.6 Listening mode for RS485 network>>doc:null||anchor="H3.6A0ListeningmodeforRS485network"]]
59 +** [[3.7 Buttons>>doc:null||anchor="H3.7Buttons"]]
60 +** [[3.8 LEDs>>doc:null||anchor="H3.8LEDs"]]
61 +* [[4. Case Study>>doc:null||anchor="H4.CaseStudy"]]
62 +* [[5. Use AT Command>>doc:null||anchor="H5.UseATCommand"]]
63 +** [[5.1 Access AT Command>>doc:null||anchor="H5.1AccessATCommand"]]
64 +** [[5.2 Common AT Command Sequence>>doc:null||anchor="H5.2CommonATCommandSequence"]]
65 +*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>doc:null||anchor="H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829"]]
66 +*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>doc:null||anchor="H5.5.2Single-channelABPmode28UsewithLG012FLG0229"]]
67 +* [[6. FAQ>>doc:null||anchor="H6.FAQ"]]
68 +** [[6.1 How to upgrade the image?>>doc:null||anchor="H6.1Howtoupgradetheimage3F"]]
69 +** [[6.2 How to change the LoRa Frequency Bands/Region?>>doc:null||anchor="H6.2HowtochangetheLoRaFrequencyBands2FRegion3F"]]
70 +** [[6.3 How many RS485-Slave can RS485-LN connects?>>doc:null||anchor="H6.3HowmanyRS485-SlavecanRS485-LNconnects3F"]]
71 +** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>doc:null||anchor="H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F"]]
72 +* [[7. Trouble Shooting>>doc:null||anchor="H7.TroubleShooting"]]
73 +** [[7.1 Downlink doesn’t work, how to solve it?>>doc:null||anchor="H7.1Downlinkdoesn2019twork2Chowtosolveit3F"]]
74 +** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>doc:null||anchor="H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F"]]
75 +* [[8. Order Info>>doc:null||anchor="H8.OrderInfo"]]
76 +* [[9.Packing Info>>doc:null||anchor="H9.PackingInfo"]]
77 +* [[10. FCC Caution for RS485LN-US915>>doc:null||anchor="H10.FCCCautionforRS485LN-US915"]]
78 +* [[11. Support>>doc:null||anchor="H11.Support"]]
79 +)))
80 +
22 22  (% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||height="15" role="presentation" title="Click and drag to move" width="15"]]
23 23  )))
24 24  
... ... @@ -107,7 +107,6 @@
107 107  * Packet engine up to 256 bytes with CRC
108 108  
109 109  
110 -
111 111  == 1.3 Features ==
112 112  
113 113  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -120,7 +120,6 @@
120 120  * Support Interrupt uplink (Since hardware version v1.2)
121 121  
122 122  
123 -
124 124  == 1.4 Applications ==
125 125  
126 126  * Smart Buildings & Home Automation
... ... @@ -131,7 +131,6 @@
131 131  * Smart Factory
132 132  
133 133  
134 -
135 135  == 1.5 Firmware Change log ==
136 136  
137 137  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -333,6 +333,8 @@
333 333  )))
334 334  )))
335 335  
392 +
393 +
336 336  === 3.3.2 Configure sensors ===
337 337  
338 338  (((
... ... @@ -359,7 +359,6 @@
359 359  
360 360  
361 361  
362 -
363 363  === 3.3.3 Configure read commands for each sampling ===
364 364  
365 365  (((
... ... @@ -699,7 +699,7 @@
699 699  
700 700  
701 701  
702 -==== (% style="color:blue" %)**Set Payload version**(%%) ====
759 +==== **Set Payload version** ====
703 703  
704 704  (((
705 705  This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
... ... @@ -706,28 +706,32 @@
706 706  )))
707 707  
708 708  * (((
709 -(% style="color:#037691" %)**AT Command:**
766 +**AT Command:**
767 +)))
710 710  
711 -**AT+PAYVER:  **Set PAYVER field = 1
712 -
713 -
769 +(% class="box infomessage" %)
770 +(((
771 +(((
772 +**AT+PAYVER: Set PAYVER field = 1**
714 714  )))
774 +)))
775 +
715 715  * (((
716 -(% style="color:#037691" %)**Downlink Payload:**
777 +**Downlink Payload:**
717 717  )))
718 718  
719 719  (((
720 -**0xAE 01**  ~-~->  Set PAYVER field =  0x01
781 +**0xAE 01**  ~-~-> Set PAYVER field =  0x01
721 721  )))
722 722  
723 723  (((
724 -**0xAE 0F**   ~-~->  Set PAYVER field =  0x0F
785 +**0xAE 0F**   ~-~-> Set PAYVER field =  0x0F
725 725  )))
726 726  
727 727  
728 728  
729 729  
730 -==== (% style="color:blue" %)**Set RS485 Sampling Commands**(%%) ====
791 +==== **Set RS485 Sampling Commands** ====
731 731  
732 732  (((
733 733  AT+COMMANDx or AT+DATACUTx
... ... @@ -742,16 +742,29 @@
742 742  )))
743 743  
744 744  * (((
745 -(% style="color:#037691" %)**AT Command:**
806 +**AT Command:**
746 746  )))
747 747  
748 -**AT+COMMANDx:  **Configure RS485 read command to sensor.
809 +(% class="box infomessage" %)
810 +(((
811 +(((
812 +**AT+COMMANDx: Configure RS485 read command to sensor.**
813 +)))
814 +)))
749 749  
750 -**AT+DATACUTx:  **Configure how to handle return from RS485 devices.
816 +(% class="box infomessage" %)
817 +(((
818 +(((
819 +**AT+DATACUTx: Configure how to handle return from RS485 devices.**
820 +)))
821 +)))
751 751  
823 +(((
824 +
825 +)))
752 752  
753 753  * (((
754 -(% style="color:#037691" %)**Downlink Payload:**
828 +**Downlink Payload:**
755 755  )))
756 756  
757 757  (((
... ... @@ -805,7 +805,7 @@
805 805  
806 806  
807 807  
808 -==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ====
882 +==== **Fast command to handle MODBUS device** ====
809 809  
810 810  (((
811 811  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
... ... @@ -844,7 +844,7 @@
844 844  
845 845  
846 846  
847 -==== (% style="color:blue" %)**RS485 command timeout**(%%) ====
921 +==== **RS485 command timeout** ====
848 848  
849 849  (((
850 850  Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
... ... @@ -855,7 +855,7 @@
855 855  )))
856 856  
857 857  * (((
858 -(% style="color:#037691" %)** AT Command:**
932 +**AT Command:**
859 859  )))
860 860  
861 861  (% class="box infomessage" %)
... ... @@ -878,7 +878,7 @@
878 878  )))
879 879  
880 880  * (((
881 -(% style="color:#037691" %)** Downlink Payload:**
955 +**Downlink Payload:**
882 882  )))
883 883  
884 884  (((
... ... @@ -900,7 +900,7 @@
900 900  
901 901  
902 902  
903 -==== (% style="color:blue" %)**Uplink payload mode**(%%) ====
977 +==== **Uplink payload mode** ====
904 904  
905 905  (((
906 906  Define to use one uplink or multiple uplinks for the sampling.
... ... @@ -911,16 +911,29 @@
911 911  )))
912 912  
913 913  * (((
914 -(% style="color:#037691" %)** AT Command:**
988 +**AT Command:**
915 915  )))
916 916  
991 +(% class="box infomessage" %)
992 +(((
993 +(((
917 917  **AT+DATAUP=0**
995 +)))
996 +)))
918 918  
998 +(% class="box infomessage" %)
999 +(((
1000 +(((
919 919  **AT+DATAUP=1**
1002 +)))
1003 +)))
920 920  
1005 +(((
1006 +
1007 +)))
921 921  
922 922  * (((
923 -(% style="color:#037691" %)** Downlink Payload:**
1010 +**Downlink Payload:**
924 924  )))
925 925  
926 926  (((
... ... @@ -934,7 +934,7 @@
934 934  
935 935  
936 936  
937 -==== (% style="color:blue" %)**Manually trigger an Uplink**(%%) ====
1024 +==== **Manually trigger an Uplink** ====
938 938  
939 939  (((
940 940  Ask device to send an uplink immediately.
... ... @@ -941,7 +941,7 @@
941 941  )))
942 942  
943 943  * (((
944 -(% style="color:#037691" %)** AT Command:**
1031 +**AT Command:**
945 945  )))
946 946  
947 947  (((
... ... @@ -953,7 +953,7 @@
953 953  )))
954 954  
955 955  * (((
956 -(% style="color:#037691" %)** Downlink Payload:**
1043 +**Downlink Payload:**
957 957  )))
958 958  
959 959  (((
... ... @@ -963,7 +963,7 @@
963 963  
964 964  
965 965  
966 -==== (% style="color:blue" %)**Clear RS485 Command**(%%) ====
1053 +==== **Clear RS485 Command** ====
967 967  
968 968  (((
969 969  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
... ... @@ -970,7 +970,7 @@
970 970  )))
971 971  
972 972  * (((
973 -(% style="color:#037691" %)** AT Command:**
1060 +**AT Command:**
974 974  )))
975 975  
976 976  (((
... ... @@ -997,7 +997,7 @@
997 997  
998 998  
999 999  * (((
1000 -(% style="color:#037691" %)** Downlink Payload:**
1087 +**Downlink Payload:**
1001 1001  )))
1002 1002  
1003 1003  (((
... ... @@ -1007,7 +1007,7 @@
1007 1007  
1008 1008  
1009 1009  
1010 -==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%) ====
1097 +==== **Set Serial Communication Parameters** ====
1011 1011  
1012 1012  (((
1013 1013  Set the Rs485 serial communication parameters:
... ... @@ -1014,7 +1014,7 @@
1014 1014  )))
1015 1015  
1016 1016  * (((
1017 -(% style="color:#037691" %)** AT Command:**
1104 +**AT Command:**
1018 1018  )))
1019 1019  
1020 1020  (((
... ... @@ -1021,28 +1021,41 @@
1021 1021  Set Baud Rate:
1022 1022  )))
1023 1023  
1024 -
1111 +(% class="box infomessage" %)
1112 +(((
1113 +(((
1025 1025  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1115 +)))
1116 +)))
1026 1026  
1027 -
1028 1028  (((
1029 1029  Set UART Parity
1030 1030  )))
1031 1031  
1032 -
1122 +(% class="box infomessage" %)
1123 +(((
1124 +(((
1033 1033  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1126 +)))
1127 +)))
1034 1034  
1035 -
1036 1036  (((
1037 1037  Set STOPBIT
1038 1038  )))
1039 1039  
1040 -
1133 +(% class="box infomessage" %)
1134 +(((
1135 +(((
1041 1041  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1137 +)))
1138 +)))
1042 1042  
1140 +(((
1141 +
1142 +)))
1043 1043  
1044 1044  * (((
1045 -(% style="color:#037691" %)** Downlink Payload:**
1145 +**Downlink Payload:**
1046 1046  )))
1047 1047  
1048 1048  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0