From version < 61.19 >
edited by Xiaoling
on 2022/06/14 11:52
To version < 61.36 >
edited by Xiaoling
on 2022/06/14 13:36
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -108,6 +108,8 @@
108 108  
109 109  
110 110  
111 +
112 +
111 111  == 1.3 Features ==
112 112  
113 113  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -121,6 +121,8 @@
121 121  
122 122  
123 123  
126 +
127 +
124 124  == 1.4 Applications ==
125 125  
126 126  * Smart Buildings & Home Automation
... ... @@ -132,6 +132,8 @@
132 132  
133 133  
134 134  
139 +
140 +
135 135  == 1.5 Firmware Change log ==
136 136  
137 137  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -333,6 +333,7 @@
333 333  )))
334 334  )))
335 335  
342 +
336 336  === 3.3.2 Configure sensors ===
337 337  
338 338  (((
... ... @@ -358,8 +358,6 @@
358 358  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
359 359  
360 360  
361 -
362 -
363 363  === 3.3.3 Configure read commands for each sampling ===
364 364  
365 365  (((
... ... @@ -590,13 +590,13 @@
590 590  * (((
591 591  (% style="color:#037691" %)**AT Command**
592 592  
593 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
594 -
595 -
598 +(((
599 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**  m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
596 596  )))
601 +)))
597 597  
598 598  (((
599 -m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
604 +
600 600  )))
601 601  
602 602  * (((
... ... @@ -637,7 +637,9 @@
637 637  )))
638 638  
639 639  (((
640 -**Example 1** ~-~-> Configure without ask for uplink (YY=0)
645 +
646 +
647 +**Example 1**  ~-~-> Configure without ask for uplink (YY=0)
641 641  )))
642 642  
643 643  (((
... ... @@ -653,6 +653,8 @@
653 653  )))
654 654  
655 655  (((
663 +
664 +
656 656  So if user want to use downlink command to control to RS485 Alarm, he can use:
657 657  )))
658 658  
... ... @@ -673,7 +673,7 @@
673 673  )))
674 674  
675 675  (((
676 -**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
685 +**Example 2**  ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
677 677  )))
678 678  
679 679  (((
... ... @@ -685,11 +685,11 @@
685 685  )))
686 686  
687 687  (((
688 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:
697 +(((
698 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:  **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
689 689  )))
690 690  
691 -(((
692 - **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
701 +
693 693  )))
694 694  
695 695  (((
... ... @@ -708,7 +708,7 @@
708 708  * (((
709 709  (% style="color:#037691" %)**AT Command:**
710 710  
711 -**AT+PAYVER:  **Set PAYVER field = 1
720 +**AT+PAYVER:    **Set PAYVER field = 1
712 712  
713 713  
714 714  )))
... ... @@ -745,9 +745,9 @@
745 745  (% style="color:#037691" %)**AT Command:**
746 746  )))
747 747  
748 -**AT+COMMANDx:  **Configure RS485 read command to sensor.
757 +**AT+COMMANDx:    **Configure RS485 read command to sensor.
749 749  
750 -**AT+DATACUTx:  **Configure how to handle return from RS485 devices.
759 +**AT+DATACUTx:        **Configure how to handle return from RS485 devices.
751 751  
752 752  
753 753  * (((
... ... @@ -787,6 +787,8 @@
787 787  )))
788 788  
789 789  (((
799 +
800 +
790 790  **Example:**
791 791  )))
792 792  
... ... @@ -808,7 +808,7 @@
808 808  ==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ====
809 809  
810 810  (((
811 -AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
822 +**AT+MBFUN** is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
812 812  )))
813 813  
814 814  (((
... ... @@ -828,18 +828,20 @@
828 828  )))
829 829  
830 830  * (((
831 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
842 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2  are not configure (0,0,0). So RS485-LN.
832 832  )))
833 833  * (((
834 -AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
845 +AT+COMMAND1= 01 03 00 10 00 08,1  ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
835 835  )))
836 836  * (((
837 -AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
848 +AT+COMMAND2= 01 02 00 40 00 10,1  ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
849 +
850 +
838 838  )))
839 839  
840 -(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
853 +(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% title="Click and drag to resize" %)​
841 841  
842 -(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
855 +(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %)​
843 843  
844 844  
845 845  
... ... @@ -856,16 +856,13 @@
856 856  
857 857  * (((
858 858  (% style="color:#037691" %)** AT Command:**
859 -)))
860 860  
861 -(% class="box infomessage" %)
862 -(((
863 -(((
864 864  **AT+CMDDLaa=hex(bb cc)*1000**
865 865  )))
866 -)))
867 867  
868 868  (((
877 +
878 +
869 869  **Example:**
870 870  )))
871 871  
... ... @@ -890,11 +890,11 @@
890 890  )))
891 891  
892 892  (((
893 - **Example:**
903 +**Example:**
894 894  )))
895 895  
896 896  (((
897 - 0xAA 01 00 01  ~-~-> Same as **AT+CMDDL1=1000 ms**
907 +**0xAA 01 00 01**  ~-~-> Same as  **AT+CMDDL1=1000 ms**
898 898  )))
899 899  
900 900  
... ... @@ -908,6 +908,8 @@
908 908  
909 909  (((
910 910  The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
921 +
922 +
911 911  )))
912 912  
913 913  * (((
... ... @@ -967,6 +967,8 @@
967 967  
968 968  (((
969 969  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
982 +
983 +
970 970  )))
971 971  
972 972  * (((
... ... @@ -1018,35 +1018,35 @@
1018 1018  )))
1019 1019  
1020 1020  (((
1021 -Set Baud Rate:
1035 +
1036 +
1037 +* Set Baud Rate
1022 1022  )))
1023 1023  
1024 -
1025 1025  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1026 1026  
1027 1027  
1028 1028  (((
1029 -Set UART Parity
1044 +* Set UART Parity
1030 1030  )))
1031 1031  
1032 -
1033 1033  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1034 1034  
1035 1035  
1036 1036  (((
1037 -Set STOPBIT
1051 +* Set STOPBIT
1038 1038  )))
1039 1039  
1040 -
1041 1041  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1042 1042  
1043 1043  
1057 +
1044 1044  * (((
1045 1045  (% style="color:#037691" %)** Downlink Payload:**
1046 1046  )))
1047 1047  
1048 1048  (((
1049 -**A7 01 aa bb**: Same  AT+BAUDR=hex(aa bb)*100
1063 +**A7 01 aa bb**:  Same  AT+BAUDR=hex(aa bb)*100
1050 1050  )))
1051 1051  
1052 1052  (((
... ... @@ -1061,11 +1061,11 @@
1061 1061  )))
1062 1062  
1063 1063  (((
1064 -A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1078 +A7 02 aa:  Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1065 1065  )))
1066 1066  
1067 1067  (((
1068 -A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1082 +A7 03 aa:  Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1069 1069  )))
1070 1070  
1071 1071  
... ... @@ -1119,7 +1119,7 @@
1119 1119  )))
1120 1120  
1121 1121  (((
1122 -**Downlink Command:**
1136 +(% style="color:#037691" %)** Downlink Command:**
1123 1123  )))
1124 1124  
1125 1125  (((
... ... @@ -1221,34 +1221,18 @@
1221 1221  
1222 1222  If device has not joined network yet:
1223 1223  
1224 -(% class="box infomessage" %)
1225 -(((
1226 -**AT+FDR**
1227 -)))
1238 +* **(% style="color:#037691" %)AT+FDR**
1239 +* **(% style="color:#037691" %)AT+NJM=0**
1240 +* **(% style="color:#037691" %)ATZ**
1228 1228  
1229 -(% class="box infomessage" %)
1230 -(((
1231 -**AT+NJM=0**
1232 -)))
1233 1233  
1234 -(% class="box infomessage" %)
1235 1235  (((
1236 -**ATZ**
1237 -)))
1238 -
1239 -
1240 -(((
1241 1241  If device already joined network:
1242 -)))
1243 1243  
1244 -(% class="box infomessage" %)
1245 -(((
1246 -**AT+NJM=0**
1247 -)))
1246 +* **(% style="color:#037691" %)AT+NJM=0**
1247 +* **(% style="color:#037691" %)ATZ**
1248 1248  
1249 -(% class="box infomessage" %)
1250 -(((
1251 -**ATZ**
1249 +
1252 1252  )))
1253 1253  
1254 1254  
... ... @@ -1393,6 +1393,10 @@
1393 1393  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1394 1394  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1395 1395  
1394 +
1395 +
1396 +
1397 +
1396 1396  = 9.Packing Info =
1397 1397  
1398 1398  
... ... @@ -1409,6 +1409,10 @@
1409 1409  * Package Size / pcs : 14.5 x 8 x 5 cm
1410 1410  * Weight / pcs : 170g
1411 1411  
1414 +
1415 +
1416 +
1417 +
1412 1412  = 10. FCC Caution for RS485LN-US915 =
1413 1413  
1414 1414  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0