From version < 61.19 >
edited by Xiaoling
on 2022/06/14 11:52
To version < 61.25 >
edited by Xiaoling
on 2022/06/14 11:55
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -333,6 +333,9 @@
333 333  )))
334 334  )))
335 335  
336 +
337 +
338 +
336 336  === 3.3.2 Configure sensors ===
337 337  
338 338  (((
... ... @@ -590,13 +590,13 @@
590 590  * (((
591 591  (% style="color:#037691" %)**AT Command**
592 592  
593 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
594 -
595 -
596 +(((
597 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**  m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
596 596  )))
599 +)))
597 597  
598 598  (((
599 -m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
602 +
600 600  )))
601 601  
602 602  * (((
... ... @@ -637,7 +637,9 @@
637 637  )))
638 638  
639 639  (((
640 -**Example 1** ~-~-> Configure without ask for uplink (YY=0)
643 +
644 +
645 +**Example 1**  ~-~-> Configure without ask for uplink (YY=0)
641 641  )))
642 642  
643 643  (((
... ... @@ -653,6 +653,8 @@
653 653  )))
654 654  
655 655  (((
661 +
662 +
656 656  So if user want to use downlink command to control to RS485 Alarm, he can use:
657 657  )))
658 658  
... ... @@ -673,7 +673,7 @@
673 673  )))
674 674  
675 675  (((
676 -**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
683 +**Example 2**  ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
677 677  )))
678 678  
679 679  (((
... ... @@ -685,11 +685,11 @@
685 685  )))
686 686  
687 687  (((
688 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:
695 +(((
696 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:  **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
689 689  )))
690 690  
691 -(((
692 - **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
699 +
693 693  )))
694 694  
695 695  (((
... ... @@ -787,6 +787,8 @@
787 787  )))
788 788  
789 789  (((
797 +
798 +
790 790  **Example:**
791 791  )))
792 792  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0