Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -333,6 +333,9 @@ 333 333 ))) 334 334 ))) 335 335 336 + 337 + 338 + 336 336 === 3.3.2 Configure sensors === 337 337 338 338 ((( ... ... @@ -357,6 +357,9 @@ 357 357 ))) 358 358 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 359 359 363 + 364 + 365 + 360 360 === 3.3.3 Configure read commands for each sampling === 361 361 362 362 ((( ... ... @@ -587,13 +587,13 @@ 587 587 * ((( 588 588 (% style="color:#037691" %)**AT Command** 589 589 590 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 591 - 592 - 596 +((( 597 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 593 593 ))) 599 +))) 594 594 595 595 ((( 596 - m:0: no CRC, 1: add CRC-16/MODBUS in the end of this command602 + 597 597 ))) 598 598 599 599 * ((( ... ... @@ -634,7 +634,9 @@ 634 634 ))) 635 635 636 636 ((( 637 -**Example 1** ~-~-> Configure without ask for uplink (YY=0) 643 + 644 + 645 +**Example 1** ~-~-> Configure without ask for uplink (YY=0) 638 638 ))) 639 639 640 640 ((( ... ... @@ -650,6 +650,8 @@ 650 650 ))) 651 651 652 652 ((( 661 + 662 + 653 653 So if user want to use downlink command to control to RS485 Alarm, he can use: 654 654 ))) 655 655 ... ... @@ -670,7 +670,7 @@ 670 670 ))) 671 671 672 672 ((( 673 -**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 683 +**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 674 674 ))) 675 675 676 676 ((( ... ... @@ -682,11 +682,11 @@ 682 682 ))) 683 683 684 684 ((( 685 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: 695 +((( 696 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 686 686 ))) 687 687 688 -((( 689 - **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 699 + 690 690 ))) 691 691 692 692 ((( ... ... @@ -705,7 +705,7 @@ 705 705 * ((( 706 706 (% style="color:#037691" %)**AT Command:** 707 707 708 -**AT+PAYVER: Set PAYVER field = 1 **718 +**AT+PAYVER: **Set PAYVER field = 1 709 709 710 710 711 711 ))) ... ... @@ -714,11 +714,11 @@ 714 714 ))) 715 715 716 716 ((( 717 -**0xAE 01** ~-~-> Set PAYVER field = 0x01 727 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 718 718 ))) 719 719 720 720 ((( 721 -**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 731 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 722 722 ))) 723 723 724 724 ... ... @@ -742,12 +742,11 @@ 742 742 (% style="color:#037691" %)**AT Command:** 743 743 ))) 744 744 745 -**AT+COMMANDx: Configure RS485 read command to sensor. **755 +**AT+COMMANDx: **Configure RS485 read command to sensor. 746 746 757 +**AT+DATACUTx: **Configure how to handle return from RS485 devices. 747 747 748 -**AT+DATACUTx: Configure how to handle return from RS485 devices.** 749 749 750 - 751 751 * ((( 752 752 (% style="color:#037691" %)**Downlink Payload:** 753 753 )))