... ... @@ -333,6 +333,9 @@
333 333  )))
334 334  )))
335 335  
336 +
337 +
338 +
336 336  === 3.3.2 Configure sensors ===
337 337  
338 338  (((
... ... @@ -357,6 +357,9 @@
357 357  )))
358 358  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
359 359  
363 +
364 +
365 +
360 360  === 3.3.3 Configure read commands for each sampling ===
361 361  
362 362  (((
... ... @@ -587,13 +587,13 @@
587 587  * (((
588 588  (% style="color:#037691" %)**AT Command**
589 589  
590 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
591 -
592 -
596 +(((
597 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**  m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
593 593  )))
599 +)))
594 594  
595 595  (((
596 -m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
602 +
597 597  )))
598 598  
599 599  * (((
... ... @@ -634,7 +634,9 @@
634 634  )))
635 635  
636 636  (((
637 -**Example 1** ~-~-> Configure without ask for uplink (YY=0)
643 +
644 +
645 +**Example 1**  ~-~-> Configure without ask for uplink (YY=0)
638 638  )))
639 639  
640 640  (((
... ... @@ -650,6 +650,8 @@
650 650  )))
651 651  
652 652  (((
661 +
662 +
653 653  So if user want to use downlink command to control to RS485 Alarm, he can use:
654 654  )))
655 655  
... ... @@ -670,7 +670,7 @@
670 670  )))
671 671  
672 672  (((
673 -**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
683 +**Example 2**  ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
674 674  )))
675 675  
676 676  (((
... ... @@ -682,11 +682,11 @@
682 682  )))
683 683  
684 684  (((
685 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:
695 +(((
696 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:  **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
686 686  )))
687 687  
688 -(((
689 - **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
699 +
690 690  )))
691 691  
692 692  (((
... ... @@ -705,7 +705,7 @@
705 705  * (((
706 706  (% style="color:#037691" %)**AT Command:**
707 707  
708 -**AT+PAYVER: Set PAYVER field = 1**
718 +**AT+PAYVER:  **Set PAYVER field = 1
709 709  
710 710  
711 711  )))
... ... @@ -714,11 +714,11 @@
714 714  )))
715 715  
716 716  (((
717 -**0xAE 01**  ~-~-> Set PAYVER field =  0x01
727 +**0xAE 01**  ~-~->  Set PAYVER field =  0x01
718 718  )))
719 719  
720 720  (((
721 -**0xAE 0F**   ~-~-> Set PAYVER field =  0x0F
731 +**0xAE 0F**   ~-~->  Set PAYVER field =  0x0F
722 722  )))
723 723  
724 724  
... ... @@ -742,12 +742,11 @@
742 742  (% style="color:#037691" %)**AT Command:**
743 743  )))
744 744  
745 -**AT+COMMANDx: Configure RS485 read command to sensor.**
755 +**AT+COMMANDx:  **Configure RS485 read command to sensor.
746 746  
757 +**AT+DATACUTx:  **Configure how to handle return from RS485 devices.
747 747  
748 -**AT+DATACUTx: Configure how to handle return from RS485 devices.**
749 749  
750 -
751 751  * (((
752 752  (% style="color:#037691" %)**Downlink Payload:**
753 753  )))