<
From version < 61.15 >
edited by Xiaoling
on 2022/06/14 11:47
To version < 62.8 >
edited by Xiaoling
on 2022/06/30 10:22
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -12,6 +12,11 @@
12 12  
13 13  
14 14  
15 +
16 +
17 +
18 +
19 +
15 15  **Table of Contents:**
16 16  
17 17  {{toc/}}
... ... @@ -80,13 +80,11 @@
80 80  ** Idle: 32mA@12v
81 81  ** 20dB Transmit: 65mA@12v
82 82  
83 -
84 84  **Interface for Model:**
85 85  
86 86  * RS485
87 87  * Power Input 7~~ 24V DC. 
88 88  
89 -
90 90  **LoRa Spec:**
91 91  
92 92  * Frequency Range:
... ... @@ -109,8 +109,6 @@
109 109  * Packet engine up to 256 bytes with CRC
110 110  
111 111  
112 -
113 -
114 114  == 1.3 Features ==
115 115  
116 116  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -123,8 +123,6 @@
123 123  * Support Interrupt uplink (Since hardware version v1.2)
124 124  
125 125  
126 -
127 -
128 128  == 1.4 Applications ==
129 129  
130 130  * Smart Buildings & Home Automation
... ... @@ -135,8 +135,6 @@
135 135  * Smart Factory
136 136  
137 137  
138 -
139 -
140 140  == 1.5 Firmware Change log ==
141 141  
142 142  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -363,7 +363,6 @@
363 363  )))
364 364  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
365 365  
366 -
367 367  === 3.3.3 Configure read commands for each sampling ===
368 368  
369 369  (((
... ... @@ -575,17 +575,18 @@
575 575  
576 576  Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server.
577 577  
578 -(% aria-label="image-20220602163333-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602163333-5.png||data-widget="image" height="263" width="1160"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
574 +(% aria-label="image-20220602163333-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602163333-5.png||data-widget="image" height="263" width="1160"]](% title="Click and drag to resize" %)​
579 579  
580 580  The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable)
581 581  
582 582  
579 +
583 583  === 3.5.3 Sensor related commands ===
584 584  
585 585  
586 586  
587 587  
588 -==== **(% style="color:#037691" %)RS485 Debug Command**(%%) ====
585 +==== (% style="color:blue" %)**RS485 Debug Command**(%%) ====
589 589  
590 590  (((
591 591  This command is used to configure the RS485 devices; they won’t be used during sampling.
... ... @@ -592,15 +592,15 @@
592 592  )))
593 593  
594 594  * (((
595 -**(% style="color:#037691" %)AT Command**
592 +(% style="color:#037691" %)**AT Command**
596 596  
597 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
598 -
599 -
594 +(((
595 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**  m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
600 600  )))
597 +)))
601 601  
602 602  (((
603 -m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
600 +
604 604  )))
605 605  
606 606  * (((
... ... @@ -641,7 +641,9 @@
641 641  )))
642 642  
643 643  (((
644 -**Example 1** ~-~-> Configure without ask for uplink (YY=0)
641 +
642 +
643 +**Example 1**  ~-~-> Configure without ask for uplink (YY=0)
645 645  )))
646 646  
647 647  (((
... ... @@ -657,6 +657,8 @@
657 657  )))
658 658  
659 659  (((
659 +
660 +
660 660  So if user want to use downlink command to control to RS485 Alarm, he can use:
661 661  )))
662 662  
... ... @@ -677,7 +677,7 @@
677 677  )))
678 678  
679 679  (((
680 -**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
681 +**Example 2**  ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
681 681  )))
682 682  
683 683  (((
... ... @@ -689,11 +689,11 @@
689 689  )))
690 690  
691 691  (((
692 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:
693 +(((
694 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:  **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
693 693  )))
694 694  
695 -(((
696 - **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
697 +
697 697  )))
698 698  
699 699  (((
... ... @@ -703,7 +703,7 @@
703 703  
704 704  
705 705  
706 -==== **(% style="color:blue" %)Set Payload version** ====
707 +==== (% style="color:blue" %)**Set Payload version**(%%) ====
707 707  
708 708  (((
709 709  This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
... ... @@ -710,32 +710,28 @@
710 710  )))
711 711  
712 712  * (((
713 -**(% style="color:#037691" %)AT Command:**
714 -)))
714 +(% style="color:#037691" %)**AT Command:**
715 715  
716 -(% class="box infomessage" %)
717 -(((
718 -(((
719 -**AT+PAYVER: Set PAYVER field = 1**
720 -)))
721 -)))
716 +**AT+PAYVER:    **Set PAYVER field = 1
722 722  
718 +
719 +)))
723 723  * (((
724 -**(% style="color:#037691" %)Downlink Payload:**
721 +(% style="color:#037691" %)**Downlink Payload:**
725 725  )))
726 726  
727 727  (((
728 -**0xAE 01**  ~-~-> Set PAYVER field =  0x01
725 +**0xAE 01**  ~-~->  Set PAYVER field =  0x01
729 729  )))
730 730  
731 731  (((
732 -**0xAE 0F**   ~-~-> Set PAYVER field =  0x0F
729 +**0xAE 0F**   ~-~->  Set PAYVER field =  0x0F
733 733  )))
734 734  
735 735  
736 736  
737 737  
738 -==== **(% style="color:blue" %)Set RS485 Sampling Commands** ====
735 +==== (% style="color:blue" %)**Set RS485 Sampling Commands**(%%) ====
739 739  
740 740  (((
741 741  AT+COMMANDx or AT+DATACUTx
... ... @@ -750,18 +750,16 @@
750 750  )))
751 751  
752 752  * (((
753 -**(% style="color:#037691" %)AT Command:**
750 +(% style="color:#037691" %)**AT Command:**
754 754  )))
755 755  
753 +**AT+COMMANDx:    **Configure RS485 read command to sensor.
756 756  
757 -**AT+COMMANDx: Configure RS485 read command to sensor.**
755 +**AT+DATACUTx:        **Configure how to handle return from RS485 devices.
758 758  
759 759  
760 -**AT+DATACUTx: Configure how to handle return from RS485 devices.**
761 -
762 -
763 763  * (((
764 -**(% style="color:#037691" %)Downlink Payload:**
759 +(% style="color:#037691" %)**Downlink Payload:**
765 765  )))
766 766  
767 767  (((
... ... @@ -797,6 +797,8 @@
797 797  )))
798 798  
799 799  (((
795 +
796 +
800 800  **Example:**
801 801  )))
802 802  
... ... @@ -815,10 +815,10 @@
815 815  
816 816  
817 817  
818 -==== **(% style="color:blue" %)Fast command to handle MODBUS device** ====
815 +==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ====
819 819  
820 820  (((
821 -AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
818 +**AT+MBFUN** is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
822 822  )))
823 823  
824 824  (((
... ... @@ -838,23 +838,25 @@
838 838  )))
839 839  
840 840  * (((
841 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
838 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2  are not configure (0,0,0). So RS485-LN.
842 842  )))
843 843  * (((
844 -AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
841 +AT+COMMAND1= 01 03 00 10 00 08,1  ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
845 845  )))
846 846  * (((
847 -AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
844 +AT+COMMAND2= 01 02 00 40 00 10,1  ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
845 +
846 +
848 848  )))
849 849  
850 -(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
849 +(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% title="Click and drag to resize" %)​
851 851  
852 -(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
851 +(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %)​
853 853  
854 854  
855 855  
856 856  
857 -==== **(% style="color:blue" %)RS485 command timeout** ====
856 +==== (% style="color:blue" %)**RS485 command timeout**(%%) ====
858 858  
859 859  (((
860 860  Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
... ... @@ -865,17 +865,14 @@
865 865  )))
866 866  
867 867  * (((
868 -**(% style="color:#037691" %) AT Command:**
869 -)))
867 +(% style="color:#037691" %)** AT Command:**
870 870  
871 -(% class="box infomessage" %)
872 -(((
873 -(((
874 874  **AT+CMDDLaa=hex(bb cc)*1000**
875 875  )))
876 -)))
877 877  
878 878  (((
873 +
874 +
879 879  **Example:**
880 880  )))
881 881  
... ... @@ -888,7 +888,7 @@
888 888  )))
889 889  
890 890  * (((
891 -**(% style="color:#037691" %) Downlink Payload:**
887 +(% style="color:#037691" %)** Downlink Payload:**
892 892  )))
893 893  
894 894  (((
... ... @@ -900,17 +900,17 @@
900 900  )))
901 901  
902 902  (((
903 - **Example:**
899 +**Example:**
904 904  )))
905 905  
906 906  (((
907 - 0xAA 01 00 01  ~-~-> Same as **AT+CMDDL1=1000 ms**
903 +**0xAA 01 00 01**  ~-~-> Same as  **AT+CMDDL1=1000 ms**
908 908  )))
909 909  
910 910  
911 911  
912 912  
913 -==== **(% style="color:blue" %)Uplink payload mode** ====
909 +==== (% style="color:blue" %)**Uplink payload mode**(%%) ====
914 914  
915 915  (((
916 916  Define to use one uplink or multiple uplinks for the sampling.
... ... @@ -918,13 +918,14 @@
918 918  
919 919  (((
920 920  The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
917 +
918 +
921 921  )))
922 922  
923 923  * (((
924 -**(% style="color:#037691" %) AT Command:**
922 +(% style="color:#037691" %)** AT Command:**
925 925  )))
926 926  
927 -
928 928  **AT+DATAUP=0**
929 929  
930 930  **AT+DATAUP=1**
... ... @@ -931,7 +931,7 @@
931 931  
932 932  
933 933  * (((
934 -**(% style="color:#037691" %) Downlink Payload:**
931 +(% style="color:#037691" %)** Downlink Payload:**
935 935  )))
936 936  
937 937  (((
... ... @@ -945,7 +945,7 @@
945 945  
946 946  
947 947  
948 -==== **(% style="color:blue" %)Manually trigger an Uplink** ====
945 +==== (% style="color:blue" %)**Manually trigger an Uplink**(%%) ====
949 949  
950 950  (((
951 951  Ask device to send an uplink immediately.
... ... @@ -952,7 +952,7 @@
952 952  )))
953 953  
954 954  * (((
955 -**(% style="color:#037691" %) AT Command:**
952 +(% style="color:#037691" %)** AT Command:**
956 956  )))
957 957  
958 958  (((
... ... @@ -964,7 +964,7 @@
964 964  )))
965 965  
966 966  * (((
967 -**(% style="color:#037691" %) Downlink Payload:**
964 +(% style="color:#037691" %)** Downlink Payload:**
968 968  )))
969 969  
970 970  (((
... ... @@ -974,14 +974,16 @@
974 974  
975 975  
976 976  
977 -==== **(% style="color:blue" %)Clear RS485 Command** ====
974 +==== (% style="color:blue" %)**Clear RS485 Command**(%%) ====
978 978  
979 979  (((
980 980  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
978 +
979 +
981 981  )))
982 982  
983 983  * (((
984 -**(% style="color:#037691" %) AT Command:**
983 +(% style="color:#037691" %)** AT Command:**
985 985  )))
986 986  
987 987  (((
... ... @@ -1008,7 +1008,7 @@
1008 1008  
1009 1009  
1010 1010  * (((
1011 -**(% style="color:#037691" %) Downlink Payload:**
1010 +(% style="color:#037691" %)** Downlink Payload:**
1012 1012  )))
1013 1013  
1014 1014  (((
... ... @@ -1018,7 +1018,7 @@
1018 1018  
1019 1019  
1020 1020  
1021 -==== **(% style="color:blue" %)Set Serial Communication Parameters** ====
1020 +==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%) ====
1022 1022  
1023 1023  (((
1024 1024  Set the Rs485 serial communication parameters:
... ... @@ -1025,39 +1025,39 @@
1025 1025  )))
1026 1026  
1027 1027  * (((
1028 -**(% style="color:#037691" %) AT Command:**
1027 +(% style="color:#037691" %)** AT Command:**
1029 1029  )))
1030 1030  
1031 1031  (((
1032 -Set Baud Rate:
1031 +
1032 +
1033 +* Set Baud Rate
1033 1033  )))
1034 1034  
1035 -
1036 1036  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1037 1037  
1038 1038  
1039 1039  (((
1040 -Set UART Parity
1040 +* Set UART Parity
1041 1041  )))
1042 1042  
1043 -
1044 1044  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1045 1045  
1046 1046  
1047 1047  (((
1048 -Set STOPBIT
1047 +* Set STOPBIT
1049 1049  )))
1050 1050  
1051 -
1052 1052  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1053 1053  
1054 1054  
1053 +
1055 1055  * (((
1056 -**(% style="color:#037691" %) Downlink Payload:**
1055 +(% style="color:#037691" %)** Downlink Payload:**
1057 1057  )))
1058 1058  
1059 1059  (((
1060 -**A7 01 aa bb**: Same  AT+BAUDR=hex(aa bb)*100
1059 +**A7 01 aa bb**:  Same  AT+BAUDR=hex(aa bb)*100
1061 1061  )))
1062 1062  
1063 1063  (((
... ... @@ -1072,11 +1072,11 @@
1072 1072  )))
1073 1073  
1074 1074  (((
1075 -A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1074 +A7 02 aa:  Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1076 1076  )))
1077 1077  
1078 1078  (((
1079 -A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1078 +A7 03 aa:  Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1080 1080  )))
1081 1081  
1082 1082  
... ... @@ -1130,7 +1130,7 @@
1130 1130  )))
1131 1131  
1132 1132  (((
1133 -**Downlink Command:**
1132 +(% style="color:#037691" %)** Downlink Command:**
1134 1134  )))
1135 1135  
1136 1136  (((
... ... @@ -1189,6 +1189,8 @@
1189 1189  |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485
1190 1190  |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1191 1191  
1191 +
1192 +
1192 1192  == 3.8 LEDs ==
1193 1193  
1194 1194  
... ... @@ -1197,6 +1197,8 @@
1197 1197  |**PWR**|Always on if there is power
1198 1198  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1199 1199  
1201 +
1202 +
1200 1200  = 4. Case Study =
1201 1201  
1202 1202  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1228,38 +1228,24 @@
1228 1228  
1229 1229  == 5.2 Common AT Command Sequence ==
1230 1230  
1234 +
1231 1231  === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1232 1232  
1233 1233  If device has not joined network yet:
1234 1234  
1235 -(% class="box infomessage" %)
1236 -(((
1237 -**AT+FDR**
1238 -)))
1239 +* (% style="color:#037691" %)**AT+FDR**
1240 +* (% style="color:#037691" %)**AT+NJM=0**
1241 +* (% style="color:#037691" %)**ATZ**
1239 1239  
1240 -(% class="box infomessage" %)
1241 1241  (((
1242 -**AT+NJM=0**
1243 -)))
1244 +
1244 1244  
1245 -(% class="box infomessage" %)
1246 -(((
1247 -**ATZ**
1248 -)))
1249 -
1250 -
1251 -(((
1252 1252  If device already joined network:
1253 -)))
1254 1254  
1255 -(% class="box infomessage" %)
1256 -(((
1257 -**AT+NJM=0**
1258 -)))
1248 +* (% style="color:#037691" %)**AT+NJM=0**
1249 +* (% style="color:#037691" %)**ATZ**
1259 1259  
1260 -(% class="box infomessage" %)
1261 -(((
1262 -**ATZ**
1251 +
1263 1263  )))
1264 1264  
1265 1265  
... ... @@ -1266,25 +1266,25 @@
1266 1266  === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1267 1267  
1268 1268  
1269 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve
1258 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve
1270 1270  
1271 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode
1260 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%) Set to ABP mode
1272 1272  
1273 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off
1262 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) Set the Adaptive Data Rate Off
1274 1274  
1275 -(% style="background-color:#dcdcdc" %)**AT+DR=5**   (%%)Set Data Rate
1264 +(% style="background-color:#dcdcdc" %)**AT+DR=5**   (%%) Set Data Rate
1276 1276  
1277 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
1266 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
1278 1278  
1279 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz
1268 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%)  Set transmit frequency to 868.4Mhz
1280 1280  
1281 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1270 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1282 1282  
1283 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5**  (%%) Set RX2DR to match the downlink DR from server. see below
1272 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5**  (%%) Set RX2DR to match the downlink DR from server. see below
1284 1284  
1285 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1274 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1286 1286  
1287 -(% style="background-color:#dcdcdc" %)**ATZ**       (%%) Reset MCU
1276 +(% style="background-color:#dcdcdc" %)**ATZ**       (%%) Reset MCU
1288 1288  
1289 1289  
1290 1290  (% style="color:red" %)**Note:**
... ... @@ -1324,15 +1324,15 @@
1324 1324  (% aria-label="1654162535040-878.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162535040-878.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1325 1325  
1326 1326  (((
1327 -**Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1316 +(% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1328 1328  )))
1329 1329  
1330 1330  (((
1331 -**Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1320 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1332 1332  )))
1333 1333  
1334 1334  (((
1335 -**Step3: **Open flashloader; choose the correct COM port to update.
1324 +(% style="color:blue" %)**Step3**(%%)**: **Open flashloader; choose the correct COM port to update.
1336 1336  )))
1337 1337  
1338 1338  (((
... ... @@ -1353,7 +1353,7 @@
1353 1353  (% aria-label="image-20220602175912-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175912-14.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1354 1354  
1355 1355  
1356 -**Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1345 +(% style="color:red" %)**Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1357 1357  
1358 1358  (% aria-label="image-20220602175638-10.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175638-10.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1359 1359  
... ... @@ -1393,16 +1393,16 @@
1393 1393  
1394 1394  (% style="color:blue" %)**XXX:**
1395 1395  
1396 -* (% style="color:blue" %)**EU433**(%%): frequency bands EU433
1397 -* (% style="color:blue" %)**EU868**(%%): frequency bands EU868
1398 -* (% style="color:blue" %)**KR920**(%%): frequency bands KR920
1399 -* (% style="color:blue" %)**CN470**(%%): frequency bands CN470
1400 -* (% style="color:blue" %)**AS923**(%%): frequency bands AS923
1401 -* (% style="color:blue" %)**AU915**(%%): frequency bands AU915
1402 -* (% style="color:blue" %)**US915**(%%): frequency bands US915
1403 -* (% style="color:blue" %)**IN865**(%%): frequency bands IN865
1404 -* (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1405 -* (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1385 +* (% style="color:red" %)**EU433**(%%):  frequency bands EU433
1386 +* (% style="color:red" %)**EU868**(%%):  frequency bands EU868
1387 +* (% style="color:red" %)**KR920**(%%):  frequency bands KR920
1388 +* (% style="color:red" %)**CN470**(%%):  frequency bands CN470
1389 +* (% style="color:red" %)**AS923**(%%):  frequency bands AS923
1390 +* (% style="color:red" %)**AU915**(%%):  frequency bands AU915
1391 +* (% style="color:red" %)**US915**(%%):  frequency bands US915
1392 +* (% style="color:red" %)**IN865**(%%):  frequency bands IN865
1393 +* (% style="color:red" %)**RU864**(%%):  frequency bands RU864
1394 +* (% style="color:red" %)**KZ865**(%%):  frequency bands KZ865
1406 1406  
1407 1407  = 9.Packing Info =
1408 1408  
... ... @@ -1435,7 +1435,7 @@
1435 1435  )))
1436 1436  
1437 1437  (((
1438 -**IMPORTANT NOTE:**
1427 +(% style="color:red" %)**IMPORTANT NOTE:**
1439 1439  )))
1440 1440  
1441 1441  (((
... ... @@ -1463,7 +1463,7 @@
1463 1463  )))
1464 1464  
1465 1465  (((
1466 -**FCC Radiation Exposure Statement:**
1455 +(% style="color:red" %)**FCC Radiation Exposure Statement:**
1467 1467  )))
1468 1468  
1469 1469  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0