From version < 61.15 >
edited by Xiaoling
on 2022/06/14 11:47
To version < 61.18 >
edited by Xiaoling
on 2022/06/14 11:51
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -80,13 +80,11 @@
80 80  ** Idle: 32mA@12v
81 81  ** 20dB Transmit: 65mA@12v
82 82  
83 -
84 84  **Interface for Model:**
85 85  
86 86  * RS485
87 87  * Power Input 7~~ 24V DC. 
88 88  
89 -
90 90  **LoRa Spec:**
91 91  
92 92  * Frequency Range:
... ... @@ -110,7 +110,6 @@
110 110  
111 111  
112 112  
113 -
114 114  == 1.3 Features ==
115 115  
116 116  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -124,7 +124,6 @@
124 124  
125 125  
126 126  
127 -
128 128  == 1.4 Applications ==
129 129  
130 130  * Smart Buildings & Home Automation
... ... @@ -136,7 +136,6 @@
136 136  
137 137  
138 138  
139 -
140 140  == 1.5 Firmware Change log ==
141 141  
142 142  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -338,7 +338,6 @@
338 338  )))
339 339  )))
340 340  
341 -
342 342  === 3.3.2 Configure sensors ===
343 343  
344 344  (((
... ... @@ -363,7 +363,6 @@
363 363  )))
364 364  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
365 365  
366 -
367 367  === 3.3.3 Configure read commands for each sampling ===
368 368  
369 369  (((
... ... @@ -585,7 +585,7 @@
585 585  
586 586  
587 587  
588 -==== **(% style="color:#037691" %)RS485 Debug Command**(%%) ====
581 +==== (% style="color:#037691" %)**RS485 Debug Command**(%%) ====
589 589  
590 590  (((
591 591  This command is used to configure the RS485 devices; they won’t be used during sampling.
... ... @@ -592,7 +592,7 @@
592 592  )))
593 593  
594 594  * (((
595 -**(% style="color:#037691" %)AT Command**
588 +(% style="color:#037691" %)**AT Command**
596 596  
597 597  **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
598 598  
... ... @@ -703,7 +703,7 @@
703 703  
704 704  
705 705  
706 -==== **(% style="color:blue" %)Set Payload version** ====
699 +==== (% style="color:blue" %)**Set Payload version**(%%) ====
707 707  
708 708  (((
709 709  This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
... ... @@ -710,32 +710,28 @@
710 710  )))
711 711  
712 712  * (((
713 -**(% style="color:#037691" %)AT Command:**
714 -)))
706 +(% style="color:#037691" %)**AT Command:**
715 715  
716 -(% class="box infomessage" %)
717 -(((
718 -(((
719 -**AT+PAYVER: Set PAYVER field = 1**
720 -)))
721 -)))
708 +**AT+PAYVER:  **Set PAYVER field = 1
722 722  
710 +
711 +)))
723 723  * (((
724 -**(% style="color:#037691" %)Downlink Payload:**
713 +(% style="color:#037691" %)**Downlink Payload:**
725 725  )))
726 726  
727 727  (((
728 -**0xAE 01**  ~-~-> Set PAYVER field =  0x01
717 +**0xAE 01**  ~-~->  Set PAYVER field =  0x01
729 729  )))
730 730  
731 731  (((
732 -**0xAE 0F**   ~-~-> Set PAYVER field =  0x0F
721 +**0xAE 0F**   ~-~->  Set PAYVER field =  0x0F
733 733  )))
734 734  
735 735  
736 736  
737 737  
738 -==== **(% style="color:blue" %)Set RS485 Sampling Commands** ====
727 +==== (% style="color:blue" %)**Set RS485 Sampling Commands**(%%) ====
739 739  
740 740  (((
741 741  AT+COMMANDx or AT+DATACUTx
... ... @@ -750,18 +750,16 @@
750 750  )))
751 751  
752 752  * (((
753 -**(% style="color:#037691" %)AT Command:**
742 +(% style="color:#037691" %)**AT Command:**
754 754  )))
755 755  
745 +**AT+COMMANDx:  **Configure RS485 read command to sensor.
756 756  
757 -**AT+COMMANDx: Configure RS485 read command to sensor.**
747 +**AT+DATACUTx:  **Configure how to handle return from RS485 devices.
758 758  
759 759  
760 -**AT+DATACUTx: Configure how to handle return from RS485 devices.**
761 -
762 -
763 763  * (((
764 -**(% style="color:#037691" %)Downlink Payload:**
751 +(% style="color:#037691" %)**Downlink Payload:**
765 765  )))
766 766  
767 767  (((
... ... @@ -815,7 +815,7 @@
815 815  
816 816  
817 817  
818 -==== **(% style="color:blue" %)Fast command to handle MODBUS device** ====
805 +==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ====
819 819  
820 820  (((
821 821  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
... ... @@ -854,7 +854,7 @@
854 854  
855 855  
856 856  
857 -==== **(% style="color:blue" %)RS485 command timeout** ====
844 +==== (% style="color:blue" %)**RS485 command timeout**(%%) ====
858 858  
859 859  (((
860 860  Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
... ... @@ -865,7 +865,7 @@
865 865  )))
866 866  
867 867  * (((
868 -**(% style="color:#037691" %) AT Command:**
855 +(% style="color:#037691" %)** AT Command:**
869 869  )))
870 870  
871 871  (% class="box infomessage" %)
... ... @@ -888,7 +888,7 @@
888 888  )))
889 889  
890 890  * (((
891 -**(% style="color:#037691" %) Downlink Payload:**
878 +(% style="color:#037691" %)** Downlink Payload:**
892 892  )))
893 893  
894 894  (((
... ... @@ -910,7 +910,7 @@
910 910  
911 911  
912 912  
913 -==== **(% style="color:blue" %)Uplink payload mode** ====
900 +==== (% style="color:blue" %)**Uplink payload mode**(%%) ====
914 914  
915 915  (((
916 916  Define to use one uplink or multiple uplinks for the sampling.
... ... @@ -921,10 +921,9 @@
921 921  )))
922 922  
923 923  * (((
924 -**(% style="color:#037691" %) AT Command:**
911 +(% style="color:#037691" %)** AT Command:**
925 925  )))
926 926  
927 -
928 928  **AT+DATAUP=0**
929 929  
930 930  **AT+DATAUP=1**
... ... @@ -931,7 +931,7 @@
931 931  
932 932  
933 933  * (((
934 -**(% style="color:#037691" %) Downlink Payload:**
920 +(% style="color:#037691" %)** Downlink Payload:**
935 935  )))
936 936  
937 937  (((
... ... @@ -945,7 +945,7 @@
945 945  
946 946  
947 947  
948 -==== **(% style="color:blue" %)Manually trigger an Uplink** ====
934 +==== (% style="color:blue" %)**Manually trigger an Uplink**(%%) ====
949 949  
950 950  (((
951 951  Ask device to send an uplink immediately.
... ... @@ -952,7 +952,7 @@
952 952  )))
953 953  
954 954  * (((
955 -**(% style="color:#037691" %) AT Command:**
941 +(% style="color:#037691" %)** AT Command:**
956 956  )))
957 957  
958 958  (((
... ... @@ -964,7 +964,7 @@
964 964  )))
965 965  
966 966  * (((
967 -**(% style="color:#037691" %) Downlink Payload:**
953 +(% style="color:#037691" %)** Downlink Payload:**
968 968  )))
969 969  
970 970  (((
... ... @@ -974,7 +974,7 @@
974 974  
975 975  
976 976  
977 -==== **(% style="color:blue" %)Clear RS485 Command** ====
963 +==== (% style="color:blue" %)**Clear RS485 Command**(%%) ====
978 978  
979 979  (((
980 980  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
... ... @@ -981,7 +981,7 @@
981 981  )))
982 982  
983 983  * (((
984 -**(% style="color:#037691" %) AT Command:**
970 +(% style="color:#037691" %)** AT Command:**
985 985  )))
986 986  
987 987  (((
... ... @@ -1008,7 +1008,7 @@
1008 1008  
1009 1009  
1010 1010  * (((
1011 -**(% style="color:#037691" %) Downlink Payload:**
997 +(% style="color:#037691" %)** Downlink Payload:**
1012 1012  )))
1013 1013  
1014 1014  (((
... ... @@ -1018,7 +1018,7 @@
1018 1018  
1019 1019  
1020 1020  
1021 -==== **(% style="color:blue" %)Set Serial Communication Parameters** ====
1007 +==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%) ====
1022 1022  
1023 1023  (((
1024 1024  Set the Rs485 serial communication parameters:
... ... @@ -1025,7 +1025,7 @@
1025 1025  )))
1026 1026  
1027 1027  * (((
1028 -**(% style="color:#037691" %) AT Command:**
1014 +(% style="color:#037691" %)** AT Command:**
1029 1029  )))
1030 1030  
1031 1031  (((
... ... @@ -1053,7 +1053,7 @@
1053 1053  
1054 1054  
1055 1055  * (((
1056 -**(% style="color:#037691" %) Downlink Payload:**
1042 +(% style="color:#037691" %)** Downlink Payload:**
1057 1057  )))
1058 1058  
1059 1059  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0