Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -134,9 +134,6 @@ 134 134 * Smart Cities 135 135 * Smart Factory 136 136 137 - 138 - 139 - 140 140 == 1.5 Firmware Change log == 141 141 142 142 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -585,7 +585,7 @@ 585 585 586 586 587 587 588 -==== **(% style="color:#037691" %)RS485 Debug Command**(%%) ====585 +==== (% style="color:#037691" %)**RS485 Debug Command**(%%) ==== 589 589 590 590 ((( 591 591 This command is used to configure the RS485 devices; they won’t be used during sampling. ... ... @@ -592,7 +592,7 @@ 592 592 ))) 593 593 594 594 * ((( 595 - **(% style="color:#037691" %)AT Command**592 +(% style="color:#037691" %)**AT Command** 596 596 597 597 **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 598 598 ... ... @@ -703,7 +703,7 @@ 703 703 704 704 705 705 706 -==== ** (% style="color:blue" %)Set Payload version** ====703 +==== **Set Payload version** ==== 707 707 708 708 ((( 709 709 This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. ... ... @@ -710,7 +710,7 @@ 710 710 ))) 711 711 712 712 * ((( 713 -** (% style="color:#037691" %)AT Command:**710 +**AT Command:** 714 714 ))) 715 715 716 716 (% class="box infomessage" %) ... ... @@ -721,7 +721,7 @@ 721 721 ))) 722 722 723 723 * ((( 724 -** (% style="color:#037691" %)Downlink Payload:**721 +**Downlink Payload:** 725 725 ))) 726 726 727 727 ((( ... ... @@ -735,7 +735,7 @@ 735 735 736 736 737 737 738 -==== ** (% style="color:blue" %)Set RS485 Sampling Commands** ====735 +==== **Set RS485 Sampling Commands** ==== 739 739 740 740 ((( 741 741 AT+COMMANDx or AT+DATACUTx ... ... @@ -750,18 +750,29 @@ 750 750 ))) 751 751 752 752 * ((( 753 -** (% style="color:#037691" %)AT Command:**750 +**AT Command:** 754 754 ))) 755 755 756 - 753 +(% class="box infomessage" %) 754 +((( 755 +((( 757 757 **AT+COMMANDx: Configure RS485 read command to sensor.** 757 +))) 758 +))) 758 758 759 - 760 +(% class="box infomessage" %) 761 +((( 762 +((( 760 760 **AT+DATACUTx: Configure how to handle return from RS485 devices.** 764 +))) 765 +))) 761 761 767 +((( 768 + 769 +))) 762 762 763 763 * ((( 764 -** (% style="color:#037691" %)Downlink Payload:**772 +**Downlink Payload:** 765 765 ))) 766 766 767 767 ((( ... ... @@ -815,7 +815,7 @@ 815 815 816 816 817 817 818 -==== ** (% style="color:blue" %)Fast command to handle MODBUS device** ====826 +==== **Fast command to handle MODBUS device** ==== 819 819 820 820 ((( 821 821 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. ... ... @@ -854,7 +854,7 @@ 854 854 855 855 856 856 857 -==== ** (% style="color:blue" %)RS485 command timeout** ====865 +==== **RS485 command timeout** ==== 858 858 859 859 ((( 860 860 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. ... ... @@ -910,7 +910,7 @@ 910 910 911 911 912 912 913 -==== ** (% style="color:blue" %)Uplink payload mode** ====921 +==== **Uplink payload mode** ==== 914 914 915 915 ((( 916 916 Define to use one uplink or multiple uplinks for the sampling. ... ... @@ -957,7 +957,7 @@ 957 957 958 958 959 959 960 -==== ** (% style="color:blue" %)Manually trigger an Uplink** ====968 +==== **Manually trigger an Uplink** ==== 961 961 962 962 ((( 963 963 Ask device to send an uplink immediately.