Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,6 +12,11 @@ 12 12 13 13 14 14 15 + 16 + 17 + 18 + 19 + 15 15 **Table of Contents:** 16 16 17 17 {{toc/}} ... ... @@ -80,13 +80,11 @@ 80 80 ** Idle: 32mA@12v 81 81 ** 20dB Transmit: 65mA@12v 82 82 83 - 84 84 **Interface for Model:** 85 85 86 86 * RS485 87 87 * Power Input 7~~ 24V DC. 88 88 89 - 90 90 **LoRa Spec:** 91 91 92 92 * Frequency Range: ... ... @@ -109,8 +109,6 @@ 109 109 * Packet engine up to 256 bytes with CRC 110 110 111 111 112 - 113 - 114 114 == 1.3 Features == 115 115 116 116 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -123,8 +123,6 @@ 123 123 * Support Interrupt uplink (Since hardware version v1.2) 124 124 125 125 126 - 127 - 128 128 == 1.4 Applications == 129 129 130 130 * Smart Buildings & Home Automation ... ... @@ -135,8 +135,6 @@ 135 135 * Smart Factory 136 136 137 137 138 - 139 - 140 140 == 1.5 Firmware Change log == 141 141 142 142 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -339,6 +339,8 @@ 339 339 ))) 340 340 341 341 339 + 340 + 342 342 === 3.3.2 Configure sensors === 343 343 344 344 ((( ... ... @@ -364,6 +364,9 @@ 364 364 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 365 365 366 366 366 + 367 + 368 + 367 367 === 3.3.3 Configure read commands for each sampling === 368 368 369 369 ((( ... ... @@ -585,7 +585,7 @@ 585 585 586 586 587 587 588 -==== **(% style="color:#037691" %)RS485 Debug Command**(%%) ====590 +==== (% style="color:#037691" %)**RS485 Debug Command**(%%) ==== 589 589 590 590 ((( 591 591 This command is used to configure the RS485 devices; they won’t be used during sampling. ... ... @@ -592,15 +592,15 @@ 592 592 ))) 593 593 594 594 * ((( 595 - **(% style="color:#037691" %)AT Command**597 +(% style="color:#037691" %)**AT Command** 596 596 597 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 598 - 599 - 599 +((( 600 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 600 600 ))) 602 +))) 601 601 602 602 ((( 603 - m:0: no CRC, 1: add CRC-16/MODBUS in the end of this command605 + 604 604 ))) 605 605 606 606 * ((( ... ... @@ -641,7 +641,9 @@ 641 641 ))) 642 642 643 643 ((( 644 -**Example 1** ~-~-> Configure without ask for uplink (YY=0) 646 + 647 + 648 +**Example 1** ~-~-> Configure without ask for uplink (YY=0) 645 645 ))) 646 646 647 647 ((( ... ... @@ -657,6 +657,8 @@ 657 657 ))) 658 658 659 659 ((( 664 + 665 + 660 660 So if user want to use downlink command to control to RS485 Alarm, he can use: 661 661 ))) 662 662 ... ... @@ -677,7 +677,7 @@ 677 677 ))) 678 678 679 679 ((( 680 -**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 686 +**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 681 681 ))) 682 682 683 683 ((( ... ... @@ -689,11 +689,11 @@ 689 689 ))) 690 690 691 691 ((( 692 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: 698 +((( 699 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 693 693 ))) 694 694 695 -((( 696 - **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 702 + 697 697 ))) 698 698 699 699 ((( ... ... @@ -703,7 +703,7 @@ 703 703 704 704 705 705 706 -==== **(% style="color:blue" %)Set Payload version** ====712 +==== (% style="color:blue" %)**Set Payload version**(%%) ==== 707 707 708 708 ((( 709 709 This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. ... ... @@ -710,32 +710,28 @@ 710 710 ))) 711 711 712 712 * ((( 713 -**(% style="color:#037691" %)AT Command:** 714 -))) 719 +(% style="color:#037691" %)**AT Command:** 715 715 716 -(% class="box infomessage" %) 717 -((( 718 -((( 719 -**AT+PAYVER: Set PAYVER field = 1** 720 -))) 721 -))) 721 +**AT+PAYVER: **Set PAYVER field = 1 722 722 723 + 724 +))) 723 723 * ((( 724 - **(% style="color:#037691" %)Downlink Payload:**726 +(% style="color:#037691" %)**Downlink Payload:** 725 725 ))) 726 726 727 727 ((( 728 -**0xAE 01** ~-~-> Set PAYVER field = 0x01 730 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 729 729 ))) 730 730 731 731 ((( 732 -**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 734 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 733 733 ))) 734 734 735 735 736 736 737 737 738 -==== **(% style="color:blue" %)Set RS485 Sampling Commands** ====740 +==== (% style="color:blue" %)**Set RS485 Sampling Commands**(%%) ==== 739 739 740 740 ((( 741 741 AT+COMMANDx or AT+DATACUTx ... ... @@ -750,18 +750,16 @@ 750 750 ))) 751 751 752 752 * ((( 753 - **(% style="color:#037691" %)AT Command:**755 +(% style="color:#037691" %)**AT Command:** 754 754 ))) 755 755 758 +**AT+COMMANDx: **Configure RS485 read command to sensor. 756 756 757 -**AT+ COMMANDx: ConfigureRS485read command tosensor.**760 +**AT+DATACUTx: **Configure how to handle return from RS485 devices. 758 758 759 759 760 -**AT+DATACUTx: Configure how to handle return from RS485 devices.** 761 - 762 - 763 763 * ((( 764 - **(% style="color:#037691" %)Downlink Payload:**764 +(% style="color:#037691" %)**Downlink Payload:** 765 765 ))) 766 766 767 767 ((( ... ... @@ -797,6 +797,8 @@ 797 797 ))) 798 798 799 799 ((( 800 + 801 + 800 800 **Example:** 801 801 ))) 802 802 ... ... @@ -815,10 +815,10 @@ 815 815 816 816 817 817 818 -==== **(% style="color:blue" %)Fast command to handle MODBUS device** ====820 +==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ==== 819 819 820 820 ((( 821 -AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 823 +**AT+MBFUN** is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 822 822 ))) 823 823 824 824 ((( ... ... @@ -838,23 +838,25 @@ 838 838 ))) 839 839 840 840 * ((( 841 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 843 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 842 842 ))) 843 843 * ((( 844 -AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 846 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 845 845 ))) 846 846 * ((( 847 -AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 849 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 850 + 851 + 848 848 ))) 849 849 850 -(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag tomove" width="15"]](% title="Click and drag to resize" %)854 +(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% title="Click and drag to resize" %) 851 851 852 -(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag tomove" width="15"]](% title="Click and drag to resize" %)856 +(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %) 853 853 854 854 855 855 856 856 857 -==== **(% style="color:blue" %)RS485 command timeout** ====861 +==== (% style="color:blue" %)**RS485 command timeout**(%%) ==== 858 858 859 859 ((( 860 860 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. ... ... @@ -865,17 +865,14 @@ 865 865 ))) 866 866 867 867 * ((( 868 -**AT Command:** 869 -))) 872 +(% style="color:#037691" %)** AT Command:** 870 870 871 -(% class="box infomessage" %) 872 -((( 873 -((( 874 874 **AT+CMDDLaa=hex(bb cc)*1000** 875 875 ))) 876 -))) 877 877 878 878 ((( 878 + 879 + 879 879 **Example:** 880 880 ))) 881 881 ... ... @@ -888,7 +888,7 @@ 888 888 ))) 889 889 890 890 * ((( 891 -**Downlink Payload:** 892 +(% style="color:#037691" %)** Downlink Payload:** 892 892 ))) 893 893 894 894 ((( ... ... @@ -900,17 +900,17 @@ 900 900 ))) 901 901 902 902 ((( 903 - 904 +**Example:** 904 904 ))) 905 905 906 906 ((( 907 - 908 +**0xAA 01 00 01** ~-~-> Same as **AT+CMDDL1=1000 ms** 908 908 ))) 909 909 910 910 911 911 912 912 913 -==== **(% style="color:blue" %)Uplink payload mode** ====914 +==== (% style="color:blue" %)**Uplink payload mode**(%%) ==== 914 914 915 915 ((( 916 916 Define to use one uplink or multiple uplinks for the sampling. ... ... @@ -918,32 +918,21 @@ 918 918 919 919 ((( 920 920 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 922 + 923 + 921 921 ))) 922 922 923 923 * ((( 924 -**AT Command:** 927 +(% style="color:#037691" %)** AT Command:** 925 925 ))) 926 926 927 -(% class="box infomessage" %) 928 -((( 929 -((( 930 930 **AT+DATAUP=0** 931 -))) 932 -))) 933 933 934 -(% class="box infomessage" %) 935 -((( 936 -((( 937 937 **AT+DATAUP=1** 938 -))) 939 -))) 940 940 941 -((( 942 - 943 -))) 944 944 945 945 * ((( 946 -**Downlink Payload:** 936 +(% style="color:#037691" %)** Downlink Payload:** 947 947 ))) 948 948 949 949 ((( ... ... @@ -957,7 +957,7 @@ 957 957 958 958 959 959 960 -==== **(% style="color:blue" %)Manually trigger an Uplink** ====950 +==== (% style="color:blue" %)**Manually trigger an Uplink**(%%) ==== 961 961 962 962 ((( 963 963 Ask device to send an uplink immediately. ... ... @@ -964,7 +964,7 @@ 964 964 ))) 965 965 966 966 * ((( 967 -**AT Command:** 957 +(% style="color:#037691" %)** AT Command:** 968 968 ))) 969 969 970 970 ((( ... ... @@ -976,7 +976,7 @@ 976 976 ))) 977 977 978 978 * ((( 979 -**Downlink Payload:** 969 +(% style="color:#037691" %)** Downlink Payload:** 980 980 ))) 981 981 982 982 ((( ... ... @@ -986,14 +986,16 @@ 986 986 987 987 988 988 989 -==== **Clear RS485 Command** ==== 979 +==== (% style="color:blue" %)**Clear RS485 Command**(%%) ==== 990 990 991 991 ((( 992 992 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 983 + 984 + 993 993 ))) 994 994 995 995 * ((( 996 -**AT Command:** 988 +(% style="color:#037691" %)** AT Command:** 997 997 ))) 998 998 999 999 ((( ... ... @@ -1020,7 +1020,7 @@ 1020 1020 1021 1021 1022 1022 * ((( 1023 -**Downlink Payload:** 1015 +(% style="color:#037691" %)** Downlink Payload:** 1024 1024 ))) 1025 1025 1026 1026 ((( ... ... @@ -1030,7 +1030,7 @@ 1030 1030 1031 1031 1032 1032 1033 -==== **Set Serial Communication Parameters** ==== 1025 +==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%) ==== 1034 1034 1035 1035 ((( 1036 1036 Set the Rs485 serial communication parameters: ... ... @@ -1037,52 +1037,39 @@ 1037 1037 ))) 1038 1038 1039 1039 * ((( 1040 -**AT Command:** 1032 +(% style="color:#037691" %)** AT Command:** 1041 1041 ))) 1042 1042 1043 1043 ((( 1044 -Set Baud Rate: 1036 + 1037 + 1038 +* Set Baud Rate 1045 1045 ))) 1046 1046 1047 -(% class="box infomessage" %) 1048 -((( 1049 -((( 1050 1050 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1051 -))) 1052 -))) 1053 1053 1043 + 1054 1054 ((( 1055 -Set UART Parity 1045 +* Set UART Parity 1056 1056 ))) 1057 1057 1058 -(% class="box infomessage" %) 1059 -((( 1060 -((( 1061 1061 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1062 -))) 1063 -))) 1064 1064 1050 + 1065 1065 ((( 1066 -Set STOPBIT 1052 +* Set STOPBIT 1067 1067 ))) 1068 1068 1069 -(% class="box infomessage" %) 1070 -((( 1071 -((( 1072 1072 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1073 -))) 1074 -))) 1075 1075 1076 -((( 1077 - 1078 -))) 1079 1079 1058 + 1080 1080 * ((( 1081 -**Downlink Payload:** 1060 +(% style="color:#037691" %)** Downlink Payload:** 1082 1082 ))) 1083 1083 1084 1084 ((( 1085 -**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1064 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1086 1086 ))) 1087 1087 1088 1088 ((( ... ... @@ -1097,11 +1097,11 @@ 1097 1097 ))) 1098 1098 1099 1099 ((( 1100 -A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1079 +A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1101 1101 ))) 1102 1102 1103 1103 ((( 1104 -A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1083 +A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1105 1105 ))) 1106 1106 1107 1107 ... ... @@ -1155,7 +1155,7 @@ 1155 1155 ))) 1156 1156 1157 1157 ((( 1158 -**Downlink Command:** 1137 +(% style="color:#037691" %)** Downlink Command:** 1159 1159 ))) 1160 1160 1161 1161 ((( ... ... @@ -1214,6 +1214,9 @@ 1214 1214 |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485 1215 1215 |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1216 1216 1196 + 1197 + 1198 + 1217 1217 == 3.8 LEDs == 1218 1218 1219 1219 ... ... @@ -1222,6 +1222,9 @@ 1222 1222 |**PWR**|Always on if there is power 1223 1223 |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1224 1224 1207 + 1208 + 1209 + 1225 1225 = 4. Case Study = 1226 1226 1227 1227 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -1253,38 +1253,24 @@ 1253 1253 1254 1254 == 5.2 Common AT Command Sequence == 1255 1255 1241 + 1256 1256 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1257 1257 1258 1258 If device has not joined network yet: 1259 1259 1260 -(% class="box infomessage" %) 1261 -((( 1262 -**AT+FDR** 1263 -))) 1246 +* (% style="color:#037691" %)**AT+FDR** 1247 +* (% style="color:#037691" %)**AT+NJM=0** 1248 +* (% style="color:#037691" %)**ATZ** 1264 1264 1265 -(% class="box infomessage" %) 1266 1266 ((( 1267 -**AT+NJM=0** 1268 -))) 1251 + 1269 1269 1270 -(% class="box infomessage" %) 1271 -((( 1272 -**ATZ** 1273 -))) 1274 - 1275 - 1276 -((( 1277 1277 If device already joined network: 1278 -))) 1279 1279 1280 -(% class="box infomessage" %) 1281 -((( 1282 -**AT+NJM=0** 1283 -))) 1255 +* (% style="color:#037691" %)**AT+NJM=0** 1256 +* (% style="color:#037691" %)**ATZ** 1284 1284 1285 -(% class="box infomessage" %) 1286 -((( 1287 -**ATZ** 1258 + 1288 1288 ))) 1289 1289 1290 1290 ... ... @@ -1291,25 +1291,25 @@ 1291 1291 === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 1292 1292 1293 1293 1294 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1265 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1295 1295 1296 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 1267 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%) Set to ABP mode 1297 1297 1298 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 1269 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) Set the Adaptive Data Rate Off 1299 1299 1300 -(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 1271 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) Set Data Rate 1301 1301 1302 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1273 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1303 1303 1304 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1275 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1305 1305 1306 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1277 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1307 1307 1308 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1279 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1309 1309 1310 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1281 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1311 1311 1312 -(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1283 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1313 1313 1314 1314 1315 1315 (% style="color:red" %)**Note:** ... ... @@ -1349,15 +1349,15 @@ 1349 1349 (% aria-label="1654162535040-878.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162535040-878.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1350 1350 1351 1351 ((( 1352 -**Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1323 +**(% style="color:blue" %)Step1(%%):** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1353 1353 ))) 1354 1354 1355 1355 ((( 1356 -**Step2** :Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].1327 +**(% style="color:blue" %)Step2(%%):** Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1357 1357 ))) 1358 1358 1359 1359 ((( 1360 -**Step3: **Open flashloader; choose the correct COM port to update. 1331 +**(% style="color:blue" %)Step3(%%): **Open flashloader; choose the correct COM port to update. 1361 1361 ))) 1362 1362 1363 1363 ((( ... ... @@ -1378,7 +1378,7 @@ 1378 1378 (% aria-label="image-20220602175912-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175912-14.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1379 1379 1380 1380 1381 -**Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1352 +**(% style="color:red" %)Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1382 1382 1383 1383 (% aria-label="image-20220602175638-10.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175638-10.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1384 1384 ... ... @@ -1418,17 +1418,20 @@ 1418 1418 1419 1419 (% style="color:blue" %)**XXX:** 1420 1420 1421 -* (% style="color: blue" %)**EU433**(%%): frequency bands EU4331422 -* (% style="color: blue" %)**EU868**(%%): frequency bands EU8681423 -* (% style="color: blue" %)**KR920**(%%): frequency bands KR9201424 -* (% style="color: blue" %)**CN470**(%%): frequency bands CN4701425 -* (% style="color: blue" %)**AS923**(%%): frequency bands AS9231426 -* (% style="color: blue" %)**AU915**(%%): frequency bands AU9151427 -* (% style="color: blue" %)**US915**(%%): frequency bands US9151428 -* (% style="color: blue" %)**IN865**(%%): frequency bands IN8651429 -* (% style="color: blue" %)**RU864**(%%): frequency bands RU8641430 -* (% style="color: blue" %)**KZ865**(%%): frequency bands KZ8651392 +* (% style="color:red" %)**EU433**(%%): frequency bands EU433 1393 +* (% style="color:red" %)**EU868**(%%): frequency bands EU868 1394 +* (% style="color:red" %)**KR920**(%%): frequency bands KR920 1395 +* (% style="color:red" %)**CN470**(%%): frequency bands CN470 1396 +* (% style="color:red" %)**AS923**(%%): frequency bands AS923 1397 +* (% style="color:red" %)**AU915**(%%): frequency bands AU915 1398 +* (% style="color:red" %)**US915**(%%): frequency bands US915 1399 +* (% style="color:red" %)**IN865**(%%): frequency bands IN865 1400 +* (% style="color:red" %)**RU864**(%%): frequency bands RU864 1401 +* (% style="color:red" %)**KZ865**(%%): frequency bands KZ865 1431 1431 1403 + 1404 + 1405 + 1432 1432 = 9.Packing Info = 1433 1433 1434 1434 ... ... @@ -1445,6 +1445,9 @@ 1445 1445 * Package Size / pcs : 14.5 x 8 x 5 cm 1446 1446 * Weight / pcs : 170g 1447 1447 1422 + 1423 + 1424 + 1448 1448 = 10. FCC Caution for RS485LN-US915 = 1449 1449 1450 1450 (((