Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,6 +12,11 @@ 12 12 13 13 14 14 15 + 16 + 17 + 18 + 19 + 15 15 **Table of Contents:** 16 16 17 17 {{toc/}} ... ... @@ -80,13 +80,11 @@ 80 80 ** Idle: 32mA@12v 81 81 ** 20dB Transmit: 65mA@12v 82 82 83 - 84 84 **Interface for Model:** 85 85 86 86 * RS485 87 87 * Power Input 7~~ 24V DC. 88 88 89 - 90 90 **LoRa Spec:** 91 91 92 92 * Frequency Range: ... ... @@ -109,8 +109,6 @@ 109 109 * Packet engine up to 256 bytes with CRC 110 110 111 111 112 - 113 - 114 114 == 1.3 Features == 115 115 116 116 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -123,8 +123,6 @@ 123 123 * Support Interrupt uplink (Since hardware version v1.2) 124 124 125 125 126 - 127 - 128 128 == 1.4 Applications == 129 129 130 130 * Smart Buildings & Home Automation ... ... @@ -135,8 +135,6 @@ 135 135 * Smart Factory 136 136 137 137 138 - 139 - 140 140 == 1.5 Firmware Change log == 141 141 142 142 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -363,7 +363,6 @@ 363 363 ))) 364 364 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 365 365 366 - 367 367 === 3.3.3 Configure read commands for each sampling === 368 368 369 369 ((( ... ... @@ -580,12 +580,13 @@ 580 580 The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable) 581 581 582 582 579 + 583 583 === 3.5.3 Sensor related commands === 584 584 585 585 586 586 587 587 588 -==== **(% style="color:#037691" %)RS485 Debug Command**(%%) ====585 +==== (% style="color:blue" %)**RS485 Debug Command**(%%) ==== 589 589 590 590 ((( 591 591 This command is used to configure the RS485 devices; they won’t be used during sampling. ... ... @@ -592,15 +592,15 @@ 592 592 ))) 593 593 594 594 * ((( 595 - **(% style="color:#037691" %)AT Command**592 +(% style="color:#037691" %)**AT Command** 596 596 597 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 598 - 599 - 594 +((( 595 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 600 600 ))) 597 +))) 601 601 602 602 ((( 603 - m:0: no CRC, 1: add CRC-16/MODBUS in the end of this command600 + 604 604 ))) 605 605 606 606 * ((( ... ... @@ -641,7 +641,9 @@ 641 641 ))) 642 642 643 643 ((( 644 -**Example 1** ~-~-> Configure without ask for uplink (YY=0) 641 + 642 + 643 +**Example 1** ~-~-> Configure without ask for uplink (YY=0) 645 645 ))) 646 646 647 647 ((( ... ... @@ -657,6 +657,8 @@ 657 657 ))) 658 658 659 659 ((( 659 + 660 + 660 660 So if user want to use downlink command to control to RS485 Alarm, he can use: 661 661 ))) 662 662 ... ... @@ -677,7 +677,7 @@ 677 677 ))) 678 678 679 679 ((( 680 -**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 681 +**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 681 681 ))) 682 682 683 683 ((( ... ... @@ -689,11 +689,11 @@ 689 689 ))) 690 690 691 691 ((( 692 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: 693 +((( 694 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 693 693 ))) 694 694 695 -((( 696 - **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 697 + 697 697 ))) 698 698 699 699 ((( ... ... @@ -703,7 +703,7 @@ 703 703 704 704 705 705 706 -==== **(% style="color:blue" %)Set Payload version** ====707 +==== (% style="color:blue" %)**Set Payload version**(%%) ==== 707 707 708 708 ((( 709 709 This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. ... ... @@ -710,32 +710,28 @@ 710 710 ))) 711 711 712 712 * ((( 713 -**(% style="color:#037691" %)AT Command:** 714 -))) 714 +(% style="color:#037691" %)**AT Command:** 715 715 716 -(% class="box infomessage" %) 717 -((( 718 -((( 719 -**AT+PAYVER: Set PAYVER field = 1** 720 -))) 721 -))) 716 +**AT+PAYVER: **Set PAYVER field = 1 722 722 718 + 719 +))) 723 723 * ((( 724 - **(% style="color:#037691" %)Downlink Payload:**721 +(% style="color:#037691" %)**Downlink Payload:** 725 725 ))) 726 726 727 727 ((( 728 -**0xAE 01** ~-~-> Set PAYVER field = 0x01 725 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 729 729 ))) 730 730 731 731 ((( 732 -**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 729 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 733 733 ))) 734 734 735 735 736 736 737 737 738 -==== **(% style="color:blue" %)Set RS485 Sampling Commands** ====735 +==== (% style="color:blue" %)**Set RS485 Sampling Commands**(%%) ==== 739 739 740 740 ((( 741 741 AT+COMMANDx or AT+DATACUTx ... ... @@ -750,18 +750,16 @@ 750 750 ))) 751 751 752 752 * ((( 753 - **(% style="color:#037691" %)AT Command:**750 +(% style="color:#037691" %)**AT Command:** 754 754 ))) 755 755 753 +**AT+COMMANDx: **Configure RS485 read command to sensor. 756 756 757 -**AT+ COMMANDx: ConfigureRS485read command tosensor.**755 +**AT+DATACUTx: **Configure how to handle return from RS485 devices. 758 758 759 759 760 -**AT+DATACUTx: Configure how to handle return from RS485 devices.** 761 - 762 - 763 763 * ((( 764 - **(% style="color:#037691" %)Downlink Payload:**759 +(% style="color:#037691" %)**Downlink Payload:** 765 765 ))) 766 766 767 767 ((( ... ... @@ -797,6 +797,8 @@ 797 797 ))) 798 798 799 799 ((( 795 + 796 + 800 800 **Example:** 801 801 ))) 802 802 ... ... @@ -815,10 +815,10 @@ 815 815 816 816 817 817 818 -==== **(% style="color:blue" %)Fast command to handle MODBUS device** ====815 +==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ==== 819 819 820 820 ((( 821 -AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 818 +**AT+MBFUN** is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 822 822 ))) 823 823 824 824 ((( ... ... @@ -838,23 +838,25 @@ 838 838 ))) 839 839 840 840 * ((( 841 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 838 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 842 842 ))) 843 843 * ((( 844 -AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 841 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 845 845 ))) 846 846 * ((( 847 -AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 844 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 845 + 846 + 848 848 ))) 849 849 850 -(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag tomove" width="15"]](% title="Click and drag to resize" %)849 +(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% title="Click and drag to resize" %) 851 851 852 -(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag tomove" width="15"]](% title="Click and drag to resize" %)851 +(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %) 853 853 854 854 855 855 856 856 857 -==== **RS485 command timeout** ==== 856 +==== (% style="color:blue" %)**RS485 command timeout**(%%) ==== 858 858 859 859 ((( 860 860 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. ... ... @@ -865,17 +865,14 @@ 865 865 ))) 866 866 867 867 * ((( 868 -**AT Command:** 869 -))) 867 +(% style="color:#037691" %)** AT Command:** 870 870 871 -(% class="box infomessage" %) 872 -((( 873 -((( 874 874 **AT+CMDDLaa=hex(bb cc)*1000** 875 875 ))) 876 -))) 877 877 878 878 ((( 873 + 874 + 879 879 **Example:** 880 880 ))) 881 881 ... ... @@ -888,7 +888,7 @@ 888 888 ))) 889 889 890 890 * ((( 891 -**Downlink Payload:** 887 +(% style="color:#037691" %)** Downlink Payload:** 892 892 ))) 893 893 894 894 ((( ... ... @@ -900,17 +900,17 @@ 900 900 ))) 901 901 902 902 ((( 903 - 899 +**Example:** 904 904 ))) 905 905 906 906 ((( 907 - 903 +**0xAA 01 00 01** ~-~-> Same as **AT+CMDDL1=1000 ms** 908 908 ))) 909 909 910 910 911 911 912 912 913 -==== **Uplink payload mode** ==== 909 +==== (% style="color:blue" %)**Uplink payload mode**(%%) ==== 914 914 915 915 ((( 916 916 Define to use one uplink or multiple uplinks for the sampling. ... ... @@ -918,32 +918,21 @@ 918 918 919 919 ((( 920 920 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 917 + 918 + 921 921 ))) 922 922 923 923 * ((( 924 -**AT Command:** 922 +(% style="color:#037691" %)** AT Command:** 925 925 ))) 926 926 927 -(% class="box infomessage" %) 928 -((( 929 -((( 930 930 **AT+DATAUP=0** 931 -))) 932 -))) 933 933 934 -(% class="box infomessage" %) 935 -((( 936 -((( 937 937 **AT+DATAUP=1** 938 -))) 939 -))) 940 940 941 -((( 942 - 943 -))) 944 944 945 945 * ((( 946 -**Downlink Payload:** 931 +(% style="color:#037691" %)** Downlink Payload:** 947 947 ))) 948 948 949 949 ((( ... ... @@ -957,7 +957,7 @@ 957 957 958 958 959 959 960 -==== **Manually trigger an Uplink** ==== 945 +==== (% style="color:blue" %)**Manually trigger an Uplink**(%%) ==== 961 961 962 962 ((( 963 963 Ask device to send an uplink immediately. ... ... @@ -964,7 +964,7 @@ 964 964 ))) 965 965 966 966 * ((( 967 -**AT Command:** 952 +(% style="color:#037691" %)** AT Command:** 968 968 ))) 969 969 970 970 ((( ... ... @@ -976,7 +976,7 @@ 976 976 ))) 977 977 978 978 * ((( 979 -**Downlink Payload:** 964 +(% style="color:#037691" %)** Downlink Payload:** 980 980 ))) 981 981 982 982 ((( ... ... @@ -986,14 +986,16 @@ 986 986 987 987 988 988 989 -==== **Clear RS485 Command** ==== 974 +==== (% style="color:blue" %)**Clear RS485 Command**(%%) ==== 990 990 991 991 ((( 992 992 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 978 + 979 + 993 993 ))) 994 994 995 995 * ((( 996 -**AT Command:** 983 +(% style="color:#037691" %)** AT Command:** 997 997 ))) 998 998 999 999 ((( ... ... @@ -1020,7 +1020,7 @@ 1020 1020 1021 1021 1022 1022 * ((( 1023 -**Downlink Payload:** 1010 +(% style="color:#037691" %)** Downlink Payload:** 1024 1024 ))) 1025 1025 1026 1026 ((( ... ... @@ -1030,7 +1030,7 @@ 1030 1030 1031 1031 1032 1032 1033 -==== **Set Serial Communication Parameters** ==== 1020 +==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%) ==== 1034 1034 1035 1035 ((( 1036 1036 Set the Rs485 serial communication parameters: ... ... @@ -1037,52 +1037,39 @@ 1037 1037 ))) 1038 1038 1039 1039 * ((( 1040 -**AT Command:** 1027 +(% style="color:#037691" %)** AT Command:** 1041 1041 ))) 1042 1042 1043 1043 ((( 1044 -Set Baud Rate: 1031 + 1032 + 1033 +* Set Baud Rate 1045 1045 ))) 1046 1046 1047 -(% class="box infomessage" %) 1048 -((( 1049 -((( 1050 1050 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1051 -))) 1052 -))) 1053 1053 1038 + 1054 1054 ((( 1055 -Set UART Parity 1040 +* Set UART Parity 1056 1056 ))) 1057 1057 1058 -(% class="box infomessage" %) 1059 -((( 1060 -((( 1061 1061 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1062 -))) 1063 -))) 1064 1064 1045 + 1065 1065 ((( 1066 -Set STOPBIT 1047 +* Set STOPBIT 1067 1067 ))) 1068 1068 1069 -(% class="box infomessage" %) 1070 -((( 1071 -((( 1072 1072 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1073 -))) 1074 -))) 1075 1075 1076 -((( 1077 - 1078 -))) 1079 1079 1053 + 1080 1080 * ((( 1081 -**Downlink Payload:** 1055 +(% style="color:#037691" %)** Downlink Payload:** 1082 1082 ))) 1083 1083 1084 1084 ((( 1085 -**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1059 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1086 1086 ))) 1087 1087 1088 1088 ((( ... ... @@ -1097,11 +1097,11 @@ 1097 1097 ))) 1098 1098 1099 1099 ((( 1100 -A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1074 +A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1101 1101 ))) 1102 1102 1103 1103 ((( 1104 -A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1078 +A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1105 1105 ))) 1106 1106 1107 1107 ... ... @@ -1155,7 +1155,7 @@ 1155 1155 ))) 1156 1156 1157 1157 ((( 1158 -**Downlink Command:** 1132 +(% style="color:#037691" %)** Downlink Command:** 1159 1159 ))) 1160 1160 1161 1161 ((( ... ... @@ -1253,38 +1253,24 @@ 1253 1253 1254 1254 == 5.2 Common AT Command Sequence == 1255 1255 1230 + 1256 1256 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1257 1257 1258 1258 If device has not joined network yet: 1259 1259 1260 -(% class="box infomessage" %) 1261 -((( 1262 -**AT+FDR** 1263 -))) 1235 +* (% style="color:#037691" %)**AT+FDR** 1236 +* (% style="color:#037691" %)**AT+NJM=0** 1237 +* (% style="color:#037691" %)**ATZ** 1264 1264 1265 -(% class="box infomessage" %) 1266 1266 ((( 1267 -**AT+NJM=0** 1268 -))) 1240 + 1269 1269 1270 -(% class="box infomessage" %) 1271 -((( 1272 -**ATZ** 1273 -))) 1274 - 1275 - 1276 -((( 1277 1277 If device already joined network: 1278 -))) 1279 1279 1280 -(% class="box infomessage" %) 1281 -((( 1282 -**AT+NJM=0** 1283 -))) 1244 +* (% style="color:#037691" %)**AT+NJM=0** 1245 +* (% style="color:#037691" %)**ATZ** 1284 1284 1285 -(% class="box infomessage" %) 1286 -((( 1287 -**ATZ** 1247 + 1288 1288 ))) 1289 1289 1290 1290 ... ... @@ -1291,25 +1291,25 @@ 1291 1291 === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 1292 1292 1293 1293 1294 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1254 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1295 1295 1296 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 1256 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%) Set to ABP mode 1297 1297 1298 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 1258 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) Set the Adaptive Data Rate Off 1299 1299 1300 -(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 1260 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) Set Data Rate 1301 1301 1302 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1262 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1303 1303 1304 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1264 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1305 1305 1306 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1266 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1307 1307 1308 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1268 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1309 1309 1310 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1270 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1311 1311 1312 -(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1272 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1313 1313 1314 1314 1315 1315 (% style="color:red" %)**Note:** ... ... @@ -1349,15 +1349,15 @@ 1349 1349 (% aria-label="1654162535040-878.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162535040-878.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1350 1350 1351 1351 ((( 1352 -**Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1312 +(% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1353 1353 ))) 1354 1354 1355 1355 ((( 1356 -**Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1316 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1357 1357 ))) 1358 1358 1359 1359 ((( 1360 -**Step3: **Open flashloader; choose the correct COM port to update. 1320 +(% style="color:blue" %)**Step3**(%%)**: **Open flashloader; choose the correct COM port to update. 1361 1361 ))) 1362 1362 1363 1363 ((( ... ... @@ -1378,7 +1378,7 @@ 1378 1378 (% aria-label="image-20220602175912-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175912-14.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1379 1379 1380 1380 1381 -**Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1341 +(% style="color:red" %)**Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1382 1382 1383 1383 (% aria-label="image-20220602175638-10.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175638-10.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1384 1384 ... ... @@ -1418,16 +1418,16 @@ 1418 1418 1419 1419 (% style="color:blue" %)**XXX:** 1420 1420 1421 -* (% style="color: blue" %)**EU433**(%%): frequency bands EU4331422 -* (% style="color: blue" %)**EU868**(%%): frequency bands EU8681423 -* (% style="color: blue" %)**KR920**(%%): frequency bands KR9201424 -* (% style="color: blue" %)**CN470**(%%): frequency bands CN4701425 -* (% style="color: blue" %)**AS923**(%%): frequency bands AS9231426 -* (% style="color: blue" %)**AU915**(%%): frequency bands AU9151427 -* (% style="color: blue" %)**US915**(%%): frequency bands US9151428 -* (% style="color: blue" %)**IN865**(%%): frequency bands IN8651429 -* (% style="color: blue" %)**RU864**(%%): frequency bands RU8641430 -* (% style="color: blue" %)**KZ865**(%%): frequency bands KZ8651381 +* (% style="color:red" %)**EU433**(%%): frequency bands EU433 1382 +* (% style="color:red" %)**EU868**(%%): frequency bands EU868 1383 +* (% style="color:red" %)**KR920**(%%): frequency bands KR920 1384 +* (% style="color:red" %)**CN470**(%%): frequency bands CN470 1385 +* (% style="color:red" %)**AS923**(%%): frequency bands AS923 1386 +* (% style="color:red" %)**AU915**(%%): frequency bands AU915 1387 +* (% style="color:red" %)**US915**(%%): frequency bands US915 1388 +* (% style="color:red" %)**IN865**(%%): frequency bands IN865 1389 +* (% style="color:red" %)**RU864**(%%): frequency bands RU864 1390 +* (% style="color:red" %)**KZ865**(%%): frequency bands KZ865 1431 1431 1432 1432 = 9.Packing Info = 1433 1433 ... ... @@ -1460,7 +1460,7 @@ 1460 1460 ))) 1461 1461 1462 1462 ((( 1463 -**IMPORTANT NOTE:** 1423 +(% style="color:red" %)**IMPORTANT NOTE:** 1464 1464 ))) 1465 1465 1466 1466 ((( ... ... @@ -1488,7 +1488,7 @@ 1488 1488 ))) 1489 1489 1490 1490 ((( 1491 -**FCC Radiation Exposure Statement:** 1451 +(% style="color:red" %)**FCC Radiation Exposure Statement:** 1492 1492 ))) 1493 1493 1494 1494 (((