<
From version < 61.12 >
edited by Xiaoling
on 2022/06/14 11:44
To version < 61.9 >
edited by Xiaoling
on 2022/06/14 11:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -134,9 +134,6 @@
134 134  * Smart Cities
135 135  * Smart Factory
136 136  
137 -
138 -
139 -
140 140  == 1.5 Firmware Change log ==
141 141  
142 142  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -585,7 +585,7 @@
585 585  
586 586  
587 587  
588 -==== **(% style="color:#037691" %)RS485 Debug Command**(%%) ====
585 +==== (% style="color:#037691" %)**RS485 Debug Command**(%%) ====
589 589  
590 590  (((
591 591  This command is used to configure the RS485 devices; they won’t be used during sampling.
... ... @@ -592,7 +592,7 @@
592 592  )))
593 593  
594 594  * (((
595 -**(% style="color:#037691" %)AT Command**
592 +(% style="color:#037691" %)**AT Command**
596 596  
597 597  **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
598 598  
... ... @@ -703,7 +703,7 @@
703 703  
704 704  
705 705  
706 -==== **(% style="color:blue" %)Set Payload version** ====
703 +==== **Set Payload version** ====
707 707  
708 708  (((
709 709  This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
... ... @@ -710,7 +710,7 @@
710 710  )))
711 711  
712 712  * (((
713 -**(% style="color:#037691" %)AT Command:**
710 +**AT Command:**
714 714  )))
715 715  
716 716  (% class="box infomessage" %)
... ... @@ -721,7 +721,7 @@
721 721  )))
722 722  
723 723  * (((
724 -**(% style="color:#037691" %)Downlink Payload:**
721 +**Downlink Payload:**
725 725  )))
726 726  
727 727  (((
... ... @@ -735,7 +735,7 @@
735 735  
736 736  
737 737  
738 -==== **(% style="color:blue" %)Set RS485 Sampling Commands** ====
735 +==== **Set RS485 Sampling Commands** ====
739 739  
740 740  (((
741 741  AT+COMMANDx or AT+DATACUTx
... ... @@ -750,18 +750,29 @@
750 750  )))
751 751  
752 752  * (((
753 -**(% style="color:#037691" %)AT Command:**
750 +**AT Command:**
754 754  )))
755 755  
756 -
753 +(% class="box infomessage" %)
754 +(((
755 +(((
757 757  **AT+COMMANDx: Configure RS485 read command to sensor.**
757 +)))
758 +)))
758 758  
759 -
760 +(% class="box infomessage" %)
761 +(((
762 +(((
760 760  **AT+DATACUTx: Configure how to handle return from RS485 devices.**
764 +)))
765 +)))
761 761  
767 +(((
768 +
769 +)))
762 762  
763 763  * (((
764 -**(% style="color:#037691" %)Downlink Payload:**
772 +**Downlink Payload:**
765 765  )))
766 766  
767 767  (((
... ... @@ -815,7 +815,7 @@
815 815  
816 816  
817 817  
818 -==== **(% style="color:blue" %)Fast command to handle MODBUS device** ====
826 +==== **Fast command to handle MODBUS device** ====
819 819  
820 820  (((
821 821  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0