<
From version < 61.11 >
edited by Xiaoling
on 2022/06/14 11:43
To version < 61.42 >
edited by Xiaoling
on 2022/06/14 13:39
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -80,13 +80,11 @@
80 80  ** Idle: 32mA@12v
81 81  ** 20dB Transmit: 65mA@12v
82 82  
83 -
84 84  **Interface for Model:**
85 85  
86 86  * RS485
87 87  * Power Input 7~~ 24V DC. 
88 88  
89 -
90 90  **LoRa Spec:**
91 91  
92 92  * Frequency Range:
... ... @@ -110,7 +110,6 @@
110 110  
111 111  
112 112  
113 -
114 114  == 1.3 Features ==
115 115  
116 116  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -124,7 +124,6 @@
124 124  
125 125  
126 126  
127 -
128 128  == 1.4 Applications ==
129 129  
130 130  * Smart Buildings & Home Automation
... ... @@ -136,7 +136,6 @@
136 136  
137 137  
138 138  
139 -
140 140  == 1.5 Firmware Change log ==
141 141  
142 142  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -338,7 +338,6 @@
338 338  )))
339 339  )))
340 340  
341 -
342 342  === 3.3.2 Configure sensors ===
343 343  
344 344  (((
... ... @@ -363,7 +363,6 @@
363 363  )))
364 364  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
365 365  
366 -
367 367  === 3.3.3 Configure read commands for each sampling ===
368 368  
369 369  (((
... ... @@ -585,7 +585,7 @@
585 585  
586 586  
587 587  
588 -==== **(% style="color:#037691" %)RS485 Debug Command**(%%) ====
581 +==== (% style="color:#037691" %)**RS485 Debug Command**(%%) ====
589 589  
590 590  (((
591 591  This command is used to configure the RS485 devices; they won’t be used during sampling.
... ... @@ -592,15 +592,15 @@
592 592  )))
593 593  
594 594  * (((
595 -**(% style="color:#037691" %)AT Command**
588 +(% style="color:#037691" %)**AT Command**
596 596  
597 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
598 -
599 -
590 +(((
591 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**  m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
600 600  )))
593 +)))
601 601  
602 602  (((
603 -m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
596 +
604 604  )))
605 605  
606 606  * (((
... ... @@ -641,7 +641,9 @@
641 641  )))
642 642  
643 643  (((
644 -**Example 1** ~-~-> Configure without ask for uplink (YY=0)
637 +
638 +
639 +**Example 1**  ~-~-> Configure without ask for uplink (YY=0)
645 645  )))
646 646  
647 647  (((
... ... @@ -657,6 +657,8 @@
657 657  )))
658 658  
659 659  (((
655 +
656 +
660 660  So if user want to use downlink command to control to RS485 Alarm, he can use:
661 661  )))
662 662  
... ... @@ -677,7 +677,7 @@
677 677  )))
678 678  
679 679  (((
680 -**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
677 +**Example 2**  ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
681 681  )))
682 682  
683 683  (((
... ... @@ -689,11 +689,11 @@
689 689  )))
690 690  
691 691  (((
692 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:
689 +(((
690 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:  **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
693 693  )))
694 694  
695 -(((
696 - **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
693 +
697 697  )))
698 698  
699 699  (((
... ... @@ -703,7 +703,7 @@
703 703  
704 704  
705 705  
706 -==== **(% style="color:blue" %)Set Payload version** ====
703 +==== (% style="color:blue" %)**Set Payload version**(%%) ====
707 707  
708 708  (((
709 709  This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
... ... @@ -710,32 +710,28 @@
710 710  )))
711 711  
712 712  * (((
713 -**(% style="color:#037691" %)AT Command:**
714 -)))
710 +(% style="color:#037691" %)**AT Command:**
715 715  
716 -(% class="box infomessage" %)
717 -(((
718 -(((
719 -**AT+PAYVER: Set PAYVER field = 1**
720 -)))
721 -)))
712 +**AT+PAYVER:    **Set PAYVER field = 1
722 722  
714 +
715 +)))
723 723  * (((
724 -**(% style="color:#037691" %)Downlink Payload:**
717 +(% style="color:#037691" %)**Downlink Payload:**
725 725  )))
726 726  
727 727  (((
728 -**0xAE 01**  ~-~-> Set PAYVER field =  0x01
721 +**0xAE 01**  ~-~->  Set PAYVER field =  0x01
729 729  )))
730 730  
731 731  (((
732 -**0xAE 0F**   ~-~-> Set PAYVER field =  0x0F
725 +**0xAE 0F**   ~-~->  Set PAYVER field =  0x0F
733 733  )))
734 734  
735 735  
736 736  
737 737  
738 -==== **Set RS485 Sampling Commands** ====
731 +==== (% style="color:blue" %)**Set RS485 Sampling Commands**(%%) ====
739 739  
740 740  (((
741 741  AT+COMMANDx or AT+DATACUTx
... ... @@ -750,29 +750,16 @@
750 750  )))
751 751  
752 752  * (((
753 -**AT Command:**
746 +(% style="color:#037691" %)**AT Command:**
754 754  )))
755 755  
756 -(% class="box infomessage" %)
757 -(((
758 -(((
759 -**AT+COMMANDx: Configure RS485 read command to sensor.**
760 -)))
761 -)))
749 +**AT+COMMANDx:    **Configure RS485 read command to sensor.
762 762  
763 -(% class="box infomessage" %)
764 -(((
765 -(((
766 -**AT+DATACUTx: Configure how to handle return from RS485 devices.**
767 -)))
768 -)))
751 +**AT+DATACUTx:        **Configure how to handle return from RS485 devices.
769 769  
770 -(((
771 -
772 -)))
773 773  
774 774  * (((
775 -**Downlink Payload:**
755 +(% style="color:#037691" %)**Downlink Payload:**
776 776  )))
777 777  
778 778  (((
... ... @@ -808,6 +808,8 @@
808 808  )))
809 809  
810 810  (((
791 +
792 +
811 811  **Example:**
812 812  )))
813 813  
... ... @@ -826,10 +826,10 @@
826 826  
827 827  
828 828  
829 -==== **Fast command to handle MODBUS device** ====
811 +==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ====
830 830  
831 831  (((
832 -AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
814 +**AT+MBFUN** is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
833 833  )))
834 834  
835 835  (((
... ... @@ -849,23 +849,25 @@
849 849  )))
850 850  
851 851  * (((
852 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
834 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2  are not configure (0,0,0). So RS485-LN.
853 853  )))
854 854  * (((
855 -AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
837 +AT+COMMAND1= 01 03 00 10 00 08,1  ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
856 856  )))
857 857  * (((
858 -AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
840 +AT+COMMAND2= 01 02 00 40 00 10,1  ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
841 +
842 +
859 859  )))
860 860  
861 -(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
845 +(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% title="Click and drag to resize" %)​
862 862  
863 -(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
847 +(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %)​
864 864  
865 865  
866 866  
867 867  
868 -==== **RS485 command timeout** ====
852 +==== (% style="color:blue" %)**RS485 command timeout**(%%) ====
869 869  
870 870  (((
871 871  Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
... ... @@ -876,17 +876,14 @@
876 876  )))
877 877  
878 878  * (((
879 -**AT Command:**
880 -)))
863 +(% style="color:#037691" %)** AT Command:**
881 881  
882 -(% class="box infomessage" %)
883 -(((
884 -(((
885 885  **AT+CMDDLaa=hex(bb cc)*1000**
886 886  )))
887 -)))
888 888  
889 889  (((
869 +
870 +
890 890  **Example:**
891 891  )))
892 892  
... ... @@ -899,7 +899,7 @@
899 899  )))
900 900  
901 901  * (((
902 -**Downlink Payload:**
883 +(% style="color:#037691" %)** Downlink Payload:**
903 903  )))
904 904  
905 905  (((
... ... @@ -911,17 +911,17 @@
911 911  )))
912 912  
913 913  (((
914 - **Example:**
895 +**Example:**
915 915  )))
916 916  
917 917  (((
918 - 0xAA 01 00 01  ~-~-> Same as **AT+CMDDL1=1000 ms**
899 +**0xAA 01 00 01**  ~-~-> Same as  **AT+CMDDL1=1000 ms**
919 919  )))
920 920  
921 921  
922 922  
923 923  
924 -==== **Uplink payload mode** ====
905 +==== (% style="color:blue" %)**Uplink payload mode**(%%) ====
925 925  
926 926  (((
927 927  Define to use one uplink or multiple uplinks for the sampling.
... ... @@ -929,32 +929,21 @@
929 929  
930 930  (((
931 931  The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
913 +
914 +
932 932  )))
933 933  
934 934  * (((
935 -**AT Command:**
918 +(% style="color:#037691" %)** AT Command:**
936 936  )))
937 937  
938 -(% class="box infomessage" %)
939 -(((
940 -(((
941 941  **AT+DATAUP=0**
942 -)))
943 -)))
944 944  
945 -(% class="box infomessage" %)
946 -(((
947 -(((
948 948  **AT+DATAUP=1**
949 -)))
950 -)))
951 951  
952 -(((
953 -
954 -)))
955 955  
956 956  * (((
957 -**Downlink Payload:**
927 +(% style="color:#037691" %)** Downlink Payload:**
958 958  )))
959 959  
960 960  (((
... ... @@ -968,7 +968,7 @@
968 968  
969 969  
970 970  
971 -==== **Manually trigger an Uplink** ====
941 +==== (% style="color:blue" %)**Manually trigger an Uplink**(%%) ====
972 972  
973 973  (((
974 974  Ask device to send an uplink immediately.
... ... @@ -975,7 +975,7 @@
975 975  )))
976 976  
977 977  * (((
978 -**AT Command:**
948 +(% style="color:#037691" %)** AT Command:**
979 979  )))
980 980  
981 981  (((
... ... @@ -987,7 +987,7 @@
987 987  )))
988 988  
989 989  * (((
990 -**Downlink Payload:**
960 +(% style="color:#037691" %)** Downlink Payload:**
991 991  )))
992 992  
993 993  (((
... ... @@ -997,14 +997,16 @@
997 997  
998 998  
999 999  
1000 -==== **Clear RS485 Command** ====
970 +==== (% style="color:blue" %)**Clear RS485 Command**(%%) ====
1001 1001  
1002 1002  (((
1003 1003  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
974 +
975 +
1004 1004  )))
1005 1005  
1006 1006  * (((
1007 -**AT Command:**
979 +(% style="color:#037691" %)** AT Command:**
1008 1008  )))
1009 1009  
1010 1010  (((
... ... @@ -1031,7 +1031,7 @@
1031 1031  
1032 1032  
1033 1033  * (((
1034 -**Downlink Payload:**
1006 +(% style="color:#037691" %)** Downlink Payload:**
1035 1035  )))
1036 1036  
1037 1037  (((
... ... @@ -1041,7 +1041,7 @@
1041 1041  
1042 1042  
1043 1043  
1044 -==== **Set Serial Communication Parameters** ====
1016 +==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%) ====
1045 1045  
1046 1046  (((
1047 1047  Set the Rs485 serial communication parameters:
... ... @@ -1048,52 +1048,39 @@
1048 1048  )))
1049 1049  
1050 1050  * (((
1051 -**AT Command:**
1023 +(% style="color:#037691" %)** AT Command:**
1052 1052  )))
1053 1053  
1054 1054  (((
1055 -Set Baud Rate:
1027 +
1028 +
1029 +* Set Baud Rate
1056 1056  )))
1057 1057  
1058 -(% class="box infomessage" %)
1059 -(((
1060 -(((
1061 1061  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1062 -)))
1063 -)))
1064 1064  
1034 +
1065 1065  (((
1066 -Set UART Parity
1036 +* Set UART Parity
1067 1067  )))
1068 1068  
1069 -(% class="box infomessage" %)
1070 -(((
1071 -(((
1072 1072  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1073 -)))
1074 -)))
1075 1075  
1041 +
1076 1076  (((
1077 -Set STOPBIT
1043 +* Set STOPBIT
1078 1078  )))
1079 1079  
1080 -(% class="box infomessage" %)
1081 -(((
1082 -(((
1083 1083  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1084 -)))
1085 -)))
1086 1086  
1087 -(((
1088 -
1089 -)))
1090 1090  
1049 +
1091 1091  * (((
1092 -**Downlink Payload:**
1051 +(% style="color:#037691" %)** Downlink Payload:**
1093 1093  )))
1094 1094  
1095 1095  (((
1096 -**A7 01 aa bb**: Same  AT+BAUDR=hex(aa bb)*100
1055 +**A7 01 aa bb**:  Same  AT+BAUDR=hex(aa bb)*100
1097 1097  )))
1098 1098  
1099 1099  (((
... ... @@ -1108,11 +1108,11 @@
1108 1108  )))
1109 1109  
1110 1110  (((
1111 -A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1070 +A7 02 aa:  Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1112 1112  )))
1113 1113  
1114 1114  (((
1115 -A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1074 +A7 03 aa:  Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1116 1116  )))
1117 1117  
1118 1118  
... ... @@ -1166,7 +1166,7 @@
1166 1166  )))
1167 1167  
1168 1168  (((
1169 -**Downlink Command:**
1128 +(% style="color:#037691" %)** Downlink Command:**
1170 1170  )))
1171 1171  
1172 1172  (((
... ... @@ -1225,6 +1225,8 @@
1225 1225  |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485
1226 1226  |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1227 1227  
1187 +
1188 +
1228 1228  == 3.8 LEDs ==
1229 1229  
1230 1230  
... ... @@ -1233,6 +1233,8 @@
1233 1233  |**PWR**|Always on if there is power
1234 1234  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1235 1235  
1197 +
1198 +
1236 1236  = 4. Case Study =
1237 1237  
1238 1238  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1264,38 +1264,24 @@
1264 1264  
1265 1265  == 5.2 Common AT Command Sequence ==
1266 1266  
1230 +
1267 1267  === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1268 1268  
1269 1269  If device has not joined network yet:
1270 1270  
1271 -(% class="box infomessage" %)
1272 -(((
1273 -**AT+FDR**
1274 -)))
1235 +* (% style="color:#037691" %)**AT+FDR**
1236 +* (% style="color:#037691" %)**AT+NJM=0**
1237 +* (% style="color:#037691" %)**ATZ**
1275 1275  
1276 -(% class="box infomessage" %)
1277 1277  (((
1278 -**AT+NJM=0**
1279 -)))
1240 +
1280 1280  
1281 -(% class="box infomessage" %)
1282 -(((
1283 -**ATZ**
1284 -)))
1285 -
1286 -
1287 -(((
1288 1288  If device already joined network:
1289 -)))
1290 1290  
1291 -(% class="box infomessage" %)
1292 -(((
1293 -**AT+NJM=0**
1294 -)))
1244 +* (% style="color:#037691" %)**AT+NJM=0**
1245 +* (% style="color:#037691" %)**ATZ**
1295 1295  
1296 -(% class="box infomessage" %)
1297 -(((
1298 -**ATZ**
1247 +
1299 1299  )))
1300 1300  
1301 1301  
... ... @@ -1302,25 +1302,25 @@
1302 1302  === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1303 1303  
1304 1304  
1305 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve
1254 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve
1306 1306  
1307 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode
1256 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%) Set to ABP mode
1308 1308  
1309 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off
1258 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) Set the Adaptive Data Rate Off
1310 1310  
1311 -(% style="background-color:#dcdcdc" %)**AT+DR=5**   (%%)Set Data Rate
1260 +(% style="background-color:#dcdcdc" %)**AT+DR=5**   (%%) Set Data Rate
1312 1312  
1313 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
1262 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
1314 1314  
1315 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz
1264 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%)  Set transmit frequency to 868.4Mhz
1316 1316  
1317 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1266 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1318 1318  
1319 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5**  (%%) Set RX2DR to match the downlink DR from server. see below
1268 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5**  (%%) Set RX2DR to match the downlink DR from server. see below
1320 1320  
1321 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1270 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1322 1322  
1323 -(% style="background-color:#dcdcdc" %)**ATZ**       (%%) Reset MCU
1272 +(% style="background-color:#dcdcdc" %)**ATZ**       (%%) Reset MCU
1324 1324  
1325 1325  
1326 1326  (% style="color:red" %)**Note:**
... ... @@ -1440,6 +1440,8 @@
1440 1440  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1441 1441  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1442 1442  
1392 +
1393 +
1443 1443  = 9.Packing Info =
1444 1444  
1445 1445  
... ... @@ -1456,6 +1456,8 @@
1456 1456  * Package Size / pcs : 14.5 x 8 x 5 cm
1457 1457  * Weight / pcs : 170g
1458 1458  
1410 +
1411 +
1459 1459  = 10. FCC Caution for RS485LN-US915 =
1460 1460  
1461 1461  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0