<
From version < 61.10 >
edited by Xiaoling
on 2022/06/14 11:41
To version < 61.14 >
edited by Xiaoling
on 2022/06/14 11:45
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -585,7 +585,7 @@
585 585  
586 586  
587 587  
588 -==== (% style="color:#037691" %)**RS485 Debug Command**(%%) ====
588 +==== **(% style="color:#037691" %)RS485 Debug Command**(%%) ====
589 589  
590 590  (((
591 591  This command is used to configure the RS485 devices; they won’t be used during sampling.
... ... @@ -592,7 +592,7 @@
592 592  )))
593 593  
594 594  * (((
595 -(% style="color:#037691" %)**AT Command**
595 +**(% style="color:#037691" %)AT Command**
596 596  
597 597  **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
598 598  
... ... @@ -703,7 +703,7 @@
703 703  
704 704  
705 705  
706 -==== **Set Payload version** ====
706 +==== **(% style="color:blue" %)Set Payload version** ====
707 707  
708 708  (((
709 709  This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
... ... @@ -710,7 +710,7 @@
710 710  )))
711 711  
712 712  * (((
713 -**AT Command:**
713 +**(% style="color:#037691" %)AT Command:**
714 714  )))
715 715  
716 716  (% class="box infomessage" %)
... ... @@ -721,7 +721,7 @@
721 721  )))
722 722  
723 723  * (((
724 -**Downlink Payload:**
724 +**(% style="color:#037691" %)Downlink Payload:**
725 725  )))
726 726  
727 727  (((
... ... @@ -735,7 +735,7 @@
735 735  
736 736  
737 737  
738 -==== **Set RS485 Sampling Commands** ====
738 +==== **(% style="color:blue" %)Set RS485 Sampling Commands** ====
739 739  
740 740  (((
741 741  AT+COMMANDx or AT+DATACUTx
... ... @@ -750,29 +750,18 @@
750 750  )))
751 751  
752 752  * (((
753 -**AT Command:**
753 +**(% style="color:#037691" %)AT Command:**
754 754  )))
755 755  
756 -(% class="box infomessage" %)
757 -(((
758 -(((
756 +
759 759  **AT+COMMANDx: Configure RS485 read command to sensor.**
760 -)))
761 -)))
762 762  
763 -(% class="box infomessage" %)
764 -(((
765 -(((
759 +
766 766  **AT+DATACUTx: Configure how to handle return from RS485 devices.**
767 -)))
768 -)))
769 769  
770 -(((
771 -
772 -)))
773 773  
774 774  * (((
775 -**Downlink Payload:**
764 +**(% style="color:#037691" %)Downlink Payload:**
776 776  )))
777 777  
778 778  (((
... ... @@ -826,7 +826,7 @@
826 826  
827 827  
828 828  
829 -==== **Fast command to handle MODBUS device** ====
818 +==== **(% style="color:blue" %)Fast command to handle MODBUS device** ====
830 830  
831 831  (((
832 832  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
... ... @@ -865,7 +865,7 @@
865 865  
866 866  
867 867  
868 -==== **RS485 command timeout** ====
857 +==== **(% style="color:blue" %)RS485 command timeout** ====
869 869  
870 870  (((
871 871  Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
... ... @@ -921,7 +921,7 @@
921 921  
922 922  
923 923  
924 -==== **Uplink payload mode** ====
913 +==== **(% style="color:blue" %)Uplink payload mode** ====
925 925  
926 926  (((
927 927  Define to use one uplink or multiple uplinks for the sampling.
... ... @@ -968,7 +968,7 @@
968 968  
969 969  
970 970  
971 -==== **Manually trigger an Uplink** ====
960 +==== **(% style="color:blue" %)Manually trigger an Uplink** ====
972 972  
973 973  (((
974 974  Ask device to send an uplink immediately.
... ... @@ -997,7 +997,7 @@
997 997  
998 998  
999 999  
1000 -==== **Clear RS485 Command** ====
989 +==== **(% style="color:blue" %)Clear RS485 Command** ====
1001 1001  
1002 1002  (((
1003 1003  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
... ... @@ -1041,7 +1041,7 @@
1041 1041  
1042 1042  
1043 1043  
1044 -==== **Set Serial Communication Parameters** ====
1033 +==== **(% style="color:blue" %)Set Serial Communication Parameters** ====
1045 1045  
1046 1046  (((
1047 1047  Set the Rs485 serial communication parameters:
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0