Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -RS485-LN – RS485 to LoRaWAN Converter User Manual1 +RS485-LN – RS485 to LoRaWAN Converter - Content
-
... ... @@ -3,6 +3,7 @@ 3 3 4 4 5 5 6 +**RS485-LN – RS485 to LoRaWAN Converter User Manual** 6 6 7 7 8 8 ... ... @@ -24,8 +24,6 @@ 24 24 ((( 25 25 ((( 26 26 ((( 27 - 28 - 29 29 The Dragino RS485-LN is a (% style="color:blue" %)**RS485 to LoRaWAN Converter**(%%). It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost. 30 30 ))) 31 31 ))) ... ... @@ -49,8 +49,6 @@ 49 49 50 50 ((( 51 51 (% style="color:blue" %)**Demo Dashboard for RS485-LN**(%%) connect to two energy meters: [[https:~~/~~/app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a>>url:https://app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a]] 52 - 53 - 54 54 ))) 55 55 ))) 56 56 ))) ... ... @@ -69,13 +69,11 @@ 69 69 ** Idle: 32mA@12v 70 70 ** 20dB Transmit: 65mA@12v 71 71 72 - 73 73 **Interface for Model:** 74 74 75 75 * RS485 76 76 * Power Input 7~~ 24V DC. 77 77 78 - 79 79 **LoRa Spec:** 80 80 81 81 * Frequency Range: ... ... @@ -98,7 +98,6 @@ 98 98 * Packet engine up to 256 bytes with CRC 99 99 100 100 101 - 102 102 == 1.3 Features == 103 103 104 104 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -111,7 +111,6 @@ 111 111 * Support Interrupt uplink (Since hardware version v1.2) 112 112 113 113 114 - 115 115 == 1.4 Applications == 116 116 117 117 * Smart Buildings & Home Automation ... ... @@ -122,7 +122,6 @@ 122 122 * Smart Factory 123 123 124 124 125 - 126 126 == 1.5 Firmware Change log == 127 127 128 128 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -191,13 +191,12 @@ 191 191 192 192 [[image:1653268227651-549.png||height="592" width="720"]] 193 193 194 - 195 195 ((( 196 196 The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3: 197 197 ))) 198 198 199 199 ((( 200 - (% style="color:blue" %)**Step 1**(%%): Create a device in TTN V3 with the OTAA keys from RS485-LN.191 +**Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-LN. 201 201 ))) 202 202 203 203 ((( ... ... @@ -207,7 +207,6 @@ 207 207 208 208 [[image:1652953462722-299.png]] 209 209 210 - 211 211 ((( 212 212 ((( 213 213 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot: ... ... @@ -214,7 +214,7 @@ 214 214 ))) 215 215 216 216 ((( 217 - **Add APP EUI in the application.**207 +Add APP EUI in the application. 218 218 ))) 219 219 ))) 220 220 ... ... @@ -230,15 +230,13 @@ 230 230 231 231 [[image:1652953542269-423.png||height="710" width="723"]] 232 232 223 +Add APP KEY and DEV EUI 233 233 234 - 235 -**Add APP KEY and DEV EUI** 236 - 237 237 [[image:1652953553383-907.png||height="514" width="724"]] 238 238 239 239 240 240 ((( 241 - (% style="color:blue" %)**Step 2**(%%): Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.229 +**Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 242 242 ))) 243 243 244 244 [[image:1652953568895-172.png||height="232" width="724"]] ... ... @@ -326,7 +326,6 @@ 326 326 327 327 328 328 329 - 330 330 === 3.3.2 Configure sensors === 331 331 332 332 ((( ... ... @@ -338,22 +338,13 @@ 338 338 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 339 339 |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 340 340 |AT+CFGDEV|(% style="width:110px" %)((( 341 -((( 342 342 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 343 -))) 344 344 345 -((( 346 346 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 347 -))) 348 348 349 -((( 350 350 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 351 -))) 352 352 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 353 353 354 - 355 - 356 - 357 357 === 3.3.3 Configure read commands for each sampling === 358 358 359 359 ((( ... ... @@ -424,7 +424,6 @@ 424 424 425 425 [[image:image-20220602153621-3.png]] 426 426 427 - 428 428 429 429 ))) 430 430 ... ... @@ -533,7 +533,7 @@ 533 533 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 534 534 535 535 536 -== 3.5 Configure RS485-L Nvia AT or Downlink ==513 +== 3.5 Configure RS485-BL via AT or Downlink == 537 537 538 538 ((( 539 539 User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands ... ... @@ -1132,29 +1132,29 @@ 1132 1132 ))) 1133 1133 1134 1134 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1135 -|=(% style="width: 1 00px;" %)(((1136 -**Command example** 1137 -)))|=(% style="width: 400px;" %)(((1112 +|=(% style="width: 161px;" %)((( 1113 +**Command example:** 1114 +)))|=(% style="width: 337px;" %)((( 1138 1138 **Function** 1139 1139 ))) 1140 -|(% style="width:1 00px" %)(((1117 +|(% style="width:161px" %)((( 1141 1141 AT+RXMODE=1,10 1142 -)))|(% style="width: 400px" %)(((1119 +)))|(% style="width:337px" %)((( 1143 1143 Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1144 1144 ))) 1145 -|(% style="width:1 00px" %)(((1122 +|(% style="width:161px" %)((( 1146 1146 AT+RXMODE=2,500 1147 -)))|(% style="width: 400px" %)(((1124 +)))|(% style="width:337px" %)((( 1148 1148 Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1149 1149 ))) 1150 -|(% style="width:1 00px" %)(((1127 +|(% style="width:161px" %)((( 1151 1151 AT+RXMODE=0,0 1152 -)))|(% style="width: 400px" %)(((1129 +)))|(% style="width:337px" %)((( 1153 1153 Disable listening mode. This is the default settings. 1154 1154 ))) 1155 -|(% style="width:1 00px" %)(((1132 +|(% style="width:161px" %)((( 1156 1156 1157 -)))|(% style="width: 400px" %)(((1134 +)))|(% style="width:337px" %)((( 1158 1158 A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1159 1159 ))) 1160 1160 ... ... @@ -1203,20 +1203,18 @@ 1203 1203 ))) 1204 1204 1205 1205 ((( 1206 -((( 1207 1207 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1208 1208 ))) 1209 -))) 1210 1210 1211 1211 1212 1212 == 3.7 Buttons == 1213 1213 1214 1214 1215 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:4 30px" %)1216 -|=(% style="width: 50px;" %)**Button**|=(% style="width: 3 61px;" %)**Feature**1217 -|(% style="width:50px" %)**ACT**|(% style="width:3 61px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**1218 -|(% style="width:50px" %)**RST**|(% style="width:3 61px" %)Reboot RS4851219 -|(% style="width:50px" %)**PRO**|(% style="width:3 61px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]1190 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:400px" %) 1191 +|=(% style="width: 50px;" %)**Button**|=(% style="width: 350px;" %)**Feature** 1192 +|(% style="width:50px" %)**ACT**|(% style="width:350px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 1193 +|(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485 1194 +|(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1220 1220 1221 1221 == 3.8 LEDs == 1222 1222 ... ... @@ -1277,9 +1277,7 @@ 1277 1277 ))) 1278 1278 1279 1279 1280 -((( 1281 1281 If device already joined network: 1282 -))) 1283 1283 1284 1284 (% class="box infomessage" %) 1285 1285 ((( ... ... @@ -1318,12 +1318,10 @@ 1318 1318 1319 1319 (% style="color:red" %)**Note:** 1320 1320 1321 -((( 1322 1322 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1323 1323 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1324 1324 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1325 1325 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1326 -))) 1327 1327 1328 1328 [[image:1654162478620-421.png]] 1329 1329 ... ... @@ -1352,25 +1352,17 @@ 1352 1352 1353 1353 [[image:1654162535040-878.png]] 1354 1354 1355 -((( 1356 1356 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1357 -))) 1358 1358 1359 -((( 1360 1360 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1361 -))) 1362 1362 1363 -((( 1364 1364 **Step3: **Open flashloader; choose the correct COM port to update. 1365 -))) 1366 1366 1367 1367 ((( 1368 1368 ((( 1369 -((( 1370 1370 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 1371 1371 ))) 1372 1372 ))) 1373 -))) 1374 1374 1375 1375 1376 1376 [[image:image-20220602175818-12.png]]