Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -RS485-LN – RS485 to LoRaWAN Converter User Manual1 +RS485-LN – RS485 to LoRaWAN Converter - Content
-
... ... @@ -3,6 +3,7 @@ 3 3 4 4 5 5 6 +**RS485-LN – RS485 to LoRaWAN Converter User Manual** 6 6 7 7 8 8 ... ... @@ -24,8 +24,6 @@ 24 24 ((( 25 25 ((( 26 26 ((( 27 - 28 - 29 29 The Dragino RS485-LN is a (% style="color:blue" %)**RS485 to LoRaWAN Converter**(%%). It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost. 30 30 ))) 31 31 ))) ... ... @@ -49,8 +49,6 @@ 49 49 50 50 ((( 51 51 (% style="color:blue" %)**Demo Dashboard for RS485-LN**(%%) connect to two energy meters: [[https:~~/~~/app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a>>url:https://app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a]] 52 - 53 - 54 54 ))) 55 55 ))) 56 56 ))) ... ... @@ -69,13 +69,11 @@ 69 69 ** Idle: 32mA@12v 70 70 ** 20dB Transmit: 65mA@12v 71 71 72 - 73 73 **Interface for Model:** 74 74 75 75 * RS485 76 76 * Power Input 7~~ 24V DC. 77 77 78 - 79 79 **LoRa Spec:** 80 80 81 81 * Frequency Range: ... ... @@ -98,7 +98,6 @@ 98 98 * Packet engine up to 256 bytes with CRC 99 99 100 100 101 - 102 102 == 1.3 Features == 103 103 104 104 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -111,7 +111,6 @@ 111 111 * Support Interrupt uplink (Since hardware version v1.2) 112 112 113 113 114 - 115 115 == 1.4 Applications == 116 116 117 117 * Smart Buildings & Home Automation ... ... @@ -122,7 +122,6 @@ 122 122 * Smart Factory 123 123 124 124 125 - 126 126 == 1.5 Firmware Change log == 127 127 128 128 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -191,13 +191,12 @@ 191 191 192 192 [[image:1653268227651-549.png||height="592" width="720"]] 193 193 194 - 195 195 ((( 196 196 The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3: 197 197 ))) 198 198 199 199 ((( 200 - (% style="color:blue" %)**Step 1**(%%): Create a device in TTN V3 with the OTAA keys from RS485-LN.191 +**Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-LN. 201 201 ))) 202 202 203 203 ((( ... ... @@ -207,7 +207,6 @@ 207 207 208 208 [[image:1652953462722-299.png]] 209 209 210 - 211 211 ((( 212 212 ((( 213 213 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot: ... ... @@ -214,7 +214,7 @@ 214 214 ))) 215 215 216 216 ((( 217 - **Add APP EUI in the application.**207 +Add APP EUI in the application. 218 218 ))) 219 219 ))) 220 220 ... ... @@ -230,15 +230,13 @@ 230 230 231 231 [[image:1652953542269-423.png||height="710" width="723"]] 232 232 223 +Add APP KEY and DEV EUI 233 233 234 - 235 -**Add APP KEY and DEV EUI** 236 - 237 237 [[image:1652953553383-907.png||height="514" width="724"]] 238 238 239 239 240 240 ((( 241 - (% style="color:blue" %)**Step 2**(%%): Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.229 +**Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 242 242 ))) 243 243 244 244 [[image:1652953568895-172.png||height="232" width="724"]] ... ... @@ -326,7 +326,6 @@ 326 326 327 327 328 328 329 - 330 330 === 3.3.2 Configure sensors === 331 331 332 332 ((( ... ... @@ -338,22 +338,15 @@ 338 338 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 339 339 |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 340 340 |AT+CFGDEV|(% style="width:110px" %)((( 341 -((( 342 342 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 343 -))) 344 344 345 -((( 346 346 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 347 -))) 348 348 349 -((( 350 350 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 351 -))) 352 352 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 353 353 354 354 355 355 356 - 357 357 === 3.3.3 Configure read commands for each sampling === 358 358 359 359 ((( ... ... @@ -1131,29 +1131,29 @@ 1131 1131 ))) 1132 1132 1133 1133 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1134 -|=(% style="width: 1 00px;" %)(((1135 -**Command example** 1136 -)))|=(% style="width: 400px;" %)(((1114 +|=(% style="width: 161px;" %)((( 1115 +**Command example:** 1116 +)))|=(% style="width: 337px;" %)((( 1137 1137 **Function** 1138 1138 ))) 1139 -|(% style="width:1 00px" %)(((1119 +|(% style="width:161px" %)((( 1140 1140 AT+RXMODE=1,10 1141 -)))|(% style="width: 400px" %)(((1121 +)))|(% style="width:337px" %)((( 1142 1142 Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1143 1143 ))) 1144 -|(% style="width:1 00px" %)(((1124 +|(% style="width:161px" %)((( 1145 1145 AT+RXMODE=2,500 1146 -)))|(% style="width: 400px" %)(((1126 +)))|(% style="width:337px" %)((( 1147 1147 Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1148 1148 ))) 1149 -|(% style="width:1 00px" %)(((1129 +|(% style="width:161px" %)((( 1150 1150 AT+RXMODE=0,0 1151 -)))|(% style="width: 400px" %)(((1131 +)))|(% style="width:337px" %)((( 1152 1152 Disable listening mode. This is the default settings. 1153 1153 ))) 1154 -|(% style="width:1 00px" %)(((1134 +|(% style="width:161px" %)((( 1155 1155 1156 -)))|(% style="width: 400px" %)(((1136 +)))|(% style="width:337px" %)((( 1157 1157 A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1158 1158 ))) 1159 1159 ... ... @@ -1202,20 +1202,18 @@ 1202 1202 ))) 1203 1203 1204 1204 ((( 1205 -((( 1206 1206 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1207 1207 ))) 1208 -))) 1209 1209 1210 1210 1211 1211 == 3.7 Buttons == 1212 1212 1213 1213 1214 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:4 30px" %)1215 -|=(% style="width: 50px;" %)**Button**|=(% style="width: 3 61px;" %)**Feature**1216 -|(% style="width:50px" %)**ACT**|(% style="width:3 61px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**1217 -|(% style="width:50px" %)**RST**|(% style="width:3 61px" %)Reboot RS4851218 -|(% style="width:50px" %)**PRO**|(% style="width:3 61px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]1192 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:400px" %) 1193 +|=(% style="width: 50px;" %)**Button**|=(% style="width: 350px;" %)**Feature** 1194 +|(% style="width:50px" %)**ACT**|(% style="width:350px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 1195 +|(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485 1196 +|(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1219 1219 1220 1220 == 3.8 LEDs == 1221 1221 ... ... @@ -1276,9 +1276,7 @@ 1276 1276 ))) 1277 1277 1278 1278 1279 -((( 1280 1280 If device already joined network: 1281 -))) 1282 1282 1283 1283 (% class="box infomessage" %) 1284 1284 ((( ... ... @@ -1317,12 +1317,10 @@ 1317 1317 1318 1318 (% style="color:red" %)**Note:** 1319 1319 1320 -((( 1321 1321 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1322 1322 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1323 1323 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1324 1324 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1325 -))) 1326 1326 1327 1327 [[image:1654162478620-421.png]] 1328 1328 ... ... @@ -1351,25 +1351,17 @@ 1351 1351 1352 1352 [[image:1654162535040-878.png]] 1353 1353 1354 -((( 1355 1355 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1356 -))) 1357 1357 1358 -((( 1359 1359 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1360 -))) 1361 1361 1362 -((( 1363 1363 **Step3: **Open flashloader; choose the correct COM port to update. 1364 -))) 1365 1365 1366 1366 ((( 1367 1367 ((( 1368 -((( 1369 1369 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 1370 1370 ))) 1371 1371 ))) 1372 -))) 1373 1373 1374 1374 1375 1375 [[image:image-20220602175818-12.png]]