Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -69,13 +69,11 @@ 69 69 ** Idle: 32mA@12v 70 70 ** 20dB Transmit: 65mA@12v 71 71 72 - 73 73 **Interface for Model:** 74 74 75 75 * RS485 76 76 * Power Input 7~~ 24V DC. 77 77 78 - 79 79 **LoRa Spec:** 80 80 81 81 * Frequency Range: ... ... @@ -249,7 +249,7 @@ 249 249 ((( 250 250 ((( 251 251 ((( 252 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485- BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.250 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-LNviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 253 253 ))) 254 254 ))) 255 255 ... ... @@ -351,6 +351,9 @@ 351 351 ))) 352 352 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 353 353 352 + 353 + 354 + 354 354 === 3.3.3 Configure read commands for each sampling === 355 355 356 356 ((( ... ... @@ -363,7 +363,7 @@ 363 363 During each sampling, the RS485-LN can support 15 commands to read sensors. And combine the return to one or several uplink payloads. 364 364 365 365 366 -**Each RS485 commands include two parts:** 367 +(% style="color:#037691" %)**Each RS485 commands include two parts:** 367 367 368 368 ~1. What commands RS485-LN will send to the RS485 sensors. There are total 15 commands from **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF**. All commands are of same grammar. 369 369 ... ... @@ -374,15 +374,14 @@ 374 374 375 375 After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**. 376 376 377 - 378 378 Below are examples for the how above AT Commands works. 379 379 380 380 381 -**AT+COMMANDx : **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is: 381 +(% style="color:#037691" %)**AT+COMMANDx **(%%)**: **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is: 382 382 383 383 (% border="1" style="background-color:#4bacc6; color:white; width:499px" %) 384 384 |(% style="width:496px" %)((( 385 -**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 385 +(% style="color:#037691" %)**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 386 386 387 387 **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent** 388 388 ... ... @@ -394,7 +394,7 @@ 394 394 In the RS485-LN, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same. 395 395 396 396 397 -**AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes. 397 +(% style="color:#037691" %)**AT+DATACUTx **(%%)**: **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes. 398 398 399 399 (% border="1" style="background-color:#4bacc6; color:white; width:510px" %) 400 400 |(% style="width:510px" %)((( ... ... @@ -407,20 +407,21 @@ 407 407 408 408 **Examples:** 409 409 410 -* Grab bytes :410 +* (% style="color:#037691" %)**Grab bytes** 411 411 412 412 [[image:image-20220602153621-1.png]] 413 413 414 414 415 -* Grab a section .415 +* (% style="color:#037691" %)**Grab a section** 416 416 417 417 [[image:image-20220602153621-2.png]] 418 418 419 419 420 -* Grab different sections .420 +* (% style="color:#037691" %)**Grab different sections** 421 421 422 422 [[image:image-20220602153621-3.png]] 423 423 424 + 424 424 425 425 ))) 426 426 ... ... @@ -500,6 +500,7 @@ 500 500 [[image:1654157178836-407.png]] 501 501 502 502 504 + 503 503 === 3.3.5 Uplink on demand === 504 504 505 505 Except uplink periodically, RS485-LN is able to uplink on demand. The server send downlink command to RS485-LN and RS485 will uplink data base on the command. ... ... @@ -529,7 +529,7 @@ 529 529 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 530 530 531 531 532 -== 3.5 Configure RS485- BL via AT or Downlink ==534 +== 3.5 Configure RS485-LN via AT or Downlink == 533 533 534 534 ((( 535 535 User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands ... ... @@ -695,7 +695,7 @@ 695 695 ==== **Set Payload version** ==== 696 696 697 697 ((( 698 -This is the first byte of the uplink payload. RS485- BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.700 +This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 699 699 ))) 700 700 701 701 * ((( ... ... @@ -793,7 +793,7 @@ 793 793 XX XX XX XX: AT+COMMAND or AT+DATACUT command 794 794 ))) 795 795 * ((( 796 -YY: If YY=0, RS485- BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.798 +YY: If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 797 797 ))) 798 798 799 799 ((( ... ... @@ -1232,7 +1232,7 @@ 1232 1232 == 5.1 Access AT Command == 1233 1233 1234 1234 ((( 1235 -RS485- BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.1237 +RS485-LN supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-LN to use AT command, as below. 1236 1236 ))) 1237 1237 1238 1238 [[image:1654162355560-817.png]] ... ... @@ -1239,7 +1239,7 @@ 1239 1239 1240 1240 1241 1241 ((( 1242 -In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485- BL. The default password is 123456. Below is the output for reference:1244 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-LN. The default password is 123456. Below is the output for reference: 1243 1243 ))) 1244 1244 1245 1245 [[image:1654162368066-342.png]] ... ... @@ -1388,9 +1388,9 @@ 1388 1388 User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download. 1389 1389 1390 1390 1391 -== 6.3 How many RS485-Slave can RS485- BL connects? ==1393 +== 6.3 How many RS485-Slave can RS485-LN connects? == 1392 1392 1393 -The RS485- BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].1395 +The RS485-LN can support max 32 RS485 devices. Each uplink command of RS485-LN can support max 16 different RS485 command. So RS485-LN can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 1394 1394 1395 1395 1396 1396 == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==