Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -RS485-LN – RS485 to LoRaWAN Converter User Manual1 +RS485-LN – RS485 to LoRaWAN Converter - Content
-
... ... @@ -1,8 +1,9 @@ 1 1 (% style="text-align:center" %) 2 -[[image:1653266934636-343.png||height="385" width="385"]] 2 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653266934636-343.png?width=385&height=385&rev=1.1||alt="1653266934636-343.png" height="385" width="385"]] 3 3 4 4 5 5 6 +**RS485-LN – RS485 to LoRaWAN Converter User Manual** 6 6 7 7 8 8 ... ... @@ -9,7 +9,59 @@ 9 9 10 10 **Table of Contents:** 11 11 12 -{{toc/}} 13 +* [[1.Introduction>>path:#H1.Introduction]] 14 +** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>path:#H1.1A0WhatisRS485-LNRS485toLoRaWANConverter]] 15 +** [[1.2 Specifications>>path:#H1.2A0Specifications]] 16 +** [[1.3 Features>>path:#H1.3Features]] 17 +** [[1.4 Applications>>path:#H1.4A0Applications]] 18 +** [[1.5 Firmware Change log>>path:#H1.5A0FirmwareChangelog]] 19 +** [[1.6 Hardware Change log>>path:#H1.6HardwareChangelog]] 20 +* [[2. Power ON Device>>path:#H2.PowerONDevice]] 21 +* [[3. Operation Mode>>path:#H3.A0OperationMode]] 22 +** [[3.1 How it works?>>path:#H3.1Howitworks3F]] 23 +** [[3.2 Example to join LoRaWAN network>>path:#H3.2ExampletojoinLoRaWANnetwork]] 24 +** [[3.3 Configure Commands to read data>>path:#H3.3ConfigureCommandstoreaddata]] 25 +*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>path:#H3.3.1onfigureUARTsettingsforRS485orTTLcommunication]] 26 +*** [[3.3.2 Configure sensors>>path:#H3.3.2Configuresensors]] 27 +*** [[3.3.3 Configure read commands for each sampling>>path:#H3.3.3Configurereadcommandsforeachsampling]] 28 +*** [[3.3.4 Compose the uplink payload>>path:#H3.3.4Composetheuplinkpayload]] 29 +*** [[3.3.5 Uplink on demand>>path:#H3.3.5Uplinkondemand]] 30 +*** [[3.3.6 Uplink on Interrupt>>path:#H3.3.6UplinkonInterrupt]] 31 +** [[3.4 Uplink Payload>>path:#H3.4UplinkPayload]] 32 +** [[3.5 Configure RS485-BL via AT or Downlink>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] 33 +*** [[3.5.1 Common Commands>>path:#H3.5.1CommonCommands]] 34 +*** [[3.5.2 Sensor related commands>>path:#H3.5.2Sensorrelatedcommands]] 35 +*** [[3.5.3 Sensor related commands>>path:#H3.5.3A0Sensorrelatedcommands]] 36 +**** [[RS485 Debug Command>>path:#HRS485DebugCommand]] 37 +**** [[Set Payload version>>path:#HSetPayloadversion]] 38 +**** [[Set RS485 Sampling Commands>>path:#HSetRS485SamplingCommands]] 39 +**** [[Fast command to handle MODBUS device>>path:#HFastcommandtohandleMODBUSdevice]] 40 +**** [[RS485 command timeout>>path:#HRS485commandtimeout]] 41 +**** [[Uplink payload mode>>path:#HUplinkpayloadmode]] 42 +**** [[Manually trigger an Uplink>>path:#HManuallytriggeranUplink]] 43 +**** [[Clear RS485 Command>>path:#HClearRS485Command]] 44 +**** [[Set Serial Communication Parameters>>path:#HSetSerialCommunicationParameters]] 45 +** [[3.6 Listening mode for RS485 network>>path:#H3.6A0ListeningmodeforRS485network]] 46 +** [[3.7 Buttons>>path:#H3.7Buttons]] 47 +** [[3.8 LEDs>>path:#H3.8LEDs]] 48 +* [[4. Case Study>>path:#H4.CaseStudy]] 49 +* [[5. Use AT Command>>path:#H5.UseATCommand]] 50 +** [[5.1 Access AT Command>>path:#H5.1AccessATCommand]] 51 +** [[5.2 Common AT Command Sequence>>path:#H5.2CommonATCommandSequence]] 52 +*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>path:#H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829]] 53 +*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>path:#H5.5.2Single-channelABPmode28UsewithLG012FLG0229]] 54 +* [[6. FAQ>>path:#H6.FAQ]] 55 +** [[6.1 How to upgrade the image?>>path:#H6.1Howtoupgradetheimage3F]] 56 +** [[6.2 How to change the LoRa Frequency Bands/Region?>>path:#H6.2HowtochangetheLoRaFrequencyBands2FRegion3F]] 57 +** [[6.3 How many RS485-Slave can RS485-BL connects?>>path:#H6.3HowmanyRS485-SlavecanRS485-BLconnects3F]] 58 +** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>path:#H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F]] 59 +* [[7. Trouble Shooting>>path:#H7.TroubleShooting]] 60 +** [[7.1 Downlink doesn’t work, how to solve it?>>path:#H7.1Downlinkdoesn2019twork2Chowtosolveit3F]] 61 +** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>path:#H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F]] 62 +* [[8. Order Info>>path:#H8.OrderInfo]] 63 +* [[9.Packing Info>>path:#H9.PackingInfo]] 64 +* [[10. FCC Caution for RS485LN-US915>>path:#H10.FCCCautionforRS485LN-US915]] 65 +* [[11. Support>>path:#H11.Support]] 13 13 14 14 15 15 ... ... @@ -51,7 +51,7 @@ 51 51 ))) 52 52 ))) 53 53 54 -[[image:1653267211009-519.png||height="419" width="724"]] 107 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653267211009-519.png?width=724&height=419&rev=1.1||alt="1653267211009-519.png" height="419" width="724"]] 55 55 56 56 57 57 == 1.2 Specifications == ... ... @@ -91,7 +91,6 @@ 91 91 * Automatic RF Sense and CAD with ultra-fast AFC. 92 92 * Packet engine up to 256 bytes with CRC 93 93 94 - 95 95 == 1.3 Features == 96 96 97 97 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -103,7 +103,6 @@ 103 103 * Support Modbus protocol 104 104 * Support Interrupt uplink (Since hardware version v1.2) 105 105 106 - 107 107 == 1.4 Applications == 108 108 109 109 * Smart Buildings & Home Automation ... ... @@ -113,7 +113,6 @@ 113 113 * Smart Cities 114 114 * Smart Factory 115 115 116 - 117 117 == 1.5 Firmware Change log == 118 118 119 119 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -147,7 +147,7 @@ 147 147 Once there is power, the RS485-LN will be on. 148 148 ))) 149 149 150 -[[image:1653268091319-405.png]] 200 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268091319-405.png?rev=1.1||alt="1653268091319-405.png"]] 151 151 152 152 153 153 ))) ... ... @@ -168,7 +168,7 @@ 168 168 169 169 Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 170 170 171 -[[image:1653268155545-638.png||height="334" width="724"]] 221 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268155545-638.png?width=724&height=334&rev=1.1||alt="1653268155545-638.png" height="334" width="724"]] 172 172 173 173 174 174 ((( ... ... @@ -180,10 +180,10 @@ 180 180 485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively. 181 181 ))) 182 182 183 -[[image:1653268227651-549.png||height="592" width="720"]] 233 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268227651-549.png?width=720&height=592&rev=1.1||alt="1653268227651-549.png" height="592" width="720"]] 184 184 185 185 ((( 186 -The LG308 is already set to connect to [[TTN V3 network >> path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:236 +The LG308 is already set to connect to (% class="wikiinternallink" %)[[TTN V3 network >>url:https://www.thethingsnetwork.org/]](%%). So what we need to now is only configure the TTN V3: 187 187 ))) 188 188 189 189 ((( ... ... @@ -195,7 +195,7 @@ 195 195 ))) 196 196 ))) 197 197 198 -[[image:1652953462722-299.png]] 248 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953462722-299.png?rev=1.1||alt="1652953462722-299.png"]] 199 199 200 200 ((( 201 201 ((( ... ... @@ -207,21 +207,21 @@ 207 207 ))) 208 208 ))) 209 209 210 -[[image:image-20220519174512-1.png]] 260 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-1.png?rev=1.1||alt="image-20220519174512-1.png"]] 211 211 212 -[[image:image-20220519174512-2.png||height="323" width="720"]] 262 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-2.png?width=720&height=323&rev=1.1||alt="image-20220519174512-2.png" height="323" width="720"]] 213 213 214 -[[image:image-20220519174512-3.png||height="556" width="724"]] 264 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-3.png?width=724&height=556&rev=1.1||alt="image-20220519174512-3.png" height="556" width="724"]] 215 215 216 -[[image:image-20220519174512-4.png]] 266 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-4.png?rev=1.1||alt="image-20220519174512-4.png"]] 217 217 218 218 You can also choose to create the device manually. 219 219 220 -[[image:1652953542269-423.png||height="710" width="723"]] 270 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953542269-423.png?width=723&height=710&rev=1.1||alt="1652953542269-423.png" height="710" width="723"]] 221 221 222 222 Add APP KEY and DEV EUI 223 223 224 -[[image:1652953553383-907.png||height="514" width="724"]] 274 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953553383-907.png?width=724&height=514&rev=1.1||alt="1652953553383-907.png" height="514" width="724"]] 225 225 226 226 227 227 ((( ... ... @@ -228,7 +228,7 @@ 228 228 **Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 229 229 ))) 230 230 231 -[[image:1652953568895-172.png||height="232" width="724"]] 281 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953568895-172.png?width=724&height=232&rev=1.1||alt="1652953568895-172.png" height="232" width="724"]] 232 232 233 233 234 234 == 3.3 Configure Commands to read data == ... ... @@ -235,15 +235,11 @@ 235 235 236 236 ((( 237 237 ((( 238 -((( 239 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 288 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 240 240 ))) 241 -))) 242 242 243 243 ((( 244 -((( 245 245 (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 246 -))) 247 247 248 248 249 249 ))) ... ... @@ -311,7 +311,6 @@ 311 311 ))) 312 312 ))) 313 313 314 - 315 315 === 3.3.2 Configure sensors === 316 316 317 317 ((( ... ... @@ -323,20 +323,13 @@ 323 323 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 324 324 |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 325 325 |AT+CFGDEV|(% style="width:110px" %)((( 326 -((( 327 327 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 328 -))) 329 329 330 -((( 331 331 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 332 -))) 333 333 334 -((( 335 335 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 336 -))) 337 337 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 338 338 339 - 340 340 === 3.3.3 Configure read commands for each sampling === 341 341 342 342 ((( ... ... @@ -395,17 +395,17 @@ 395 395 396 396 * Grab bytes: 397 397 398 -[[image:image-20220602153621-1.png]] 436 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-1.png?rev=1.1||alt="image-20220602153621-1.png"]] 399 399 400 400 401 401 * Grab a section. 402 402 403 -[[image:image-20220602153621-2.png]] 441 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-2.png?rev=1.1||alt="image-20220602153621-2.png"]] 404 404 405 405 406 406 * Grab different sections. 407 407 408 -[[image:image-20220602153621-3.png]] 446 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-3.png?rev=1.1||alt="image-20220602153621-3.png"]] 409 409 410 410 411 411 ))) ... ... @@ -440,7 +440,7 @@ 440 440 Where PAYVER is defined by AT+PAYVER, below is an example screen shot. 441 441 ))) 442 442 443 -[[image:1653269759169-150.png||height="513" width="716"]] 481 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653269759169-150.png?width=716&height=513&rev=1.1||alt="1653269759169-150.png" height="513" width="716"]] 444 444 445 445 446 446 (% style="color:#037691" %)**Examples: AT+DATAUP=1** ... ... @@ -458,7 +458,7 @@ 458 458 1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) 459 459 1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes 460 460 461 -[[image:image-20220602155039-4.png]] 499 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602155039-4.png?rev=1.1||alt="image-20220602155039-4.png"]] 462 462 463 463 464 464 So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA ... ... @@ -483,7 +483,7 @@ 483 483 484 484 Below are the uplink payloads: 485 485 486 -[[image:1654157178836-407.png]] 524 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157178836-407.png?rev=1.1||alt="1654157178836-407.png"]] 487 487 488 488 489 489 === 3.3.5 Uplink on demand === ... ... @@ -502,7 +502,7 @@ 502 502 503 503 RS485-LN support external Interrupt uplink since hardware v1.2 release. 504 504 505 -[[image:1654157342174-798.png]] 543 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157342174-798.png?rev=1.1||alt="1654157342174-798.png"]] 506 506 507 507 Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet. 508 508 ... ... @@ -510,7 +510,7 @@ 510 510 == 3.4 Uplink Payload == 511 511 512 512 513 -[[image:image-20220606110929-1.png]] 551 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220606110929-1.png?rev=1.1||alt="image-20220606110929-1.png"]] 514 514 515 515 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 516 516 ... ... @@ -526,7 +526,7 @@ 526 526 ))) 527 527 528 528 * ((( 529 -(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>> doc:Main.End.WebHome]]567 +(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 530 530 ))) 531 531 532 532 * ((( ... ... @@ -540,7 +540,7 @@ 540 540 541 541 === 3.5.1 Common Commands === 542 542 543 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>> doc:Main.End.WebHome]]581 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 544 544 545 545 546 546 === 3.5.2 Sensor related commands === ... ... @@ -547,7 +547,7 @@ 547 547 548 548 Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server. 549 549 550 -[[image:image-20220602163333-5.png||height="263" width="1160"]] 588 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602163333-5.png?width=1160&height=263&rev=1.1||alt="image-20220602163333-5.png" height="263" width="1160"]] 551 551 552 552 The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable) 553 553 ... ... @@ -672,7 +672,7 @@ 672 672 ))) 673 673 674 674 ((( 675 - [[image:1654159460680-153.png]] 713 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654159460680-153.png?rev=1.1||alt="1654159460680-153.png"]] 676 676 ))) 677 677 678 678 ... ... @@ -717,7 +717,7 @@ 717 717 ))) 718 718 719 719 ((( 720 -These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>> ||anchor="H3.3.3Configurereadcommandsforeachsampling"]].758 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#H3.3.3Configurereadcommandsforeachsampling]]. 721 721 ))) 722 722 723 723 ((( ... ... @@ -833,9 +833,9 @@ 833 833 AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 834 834 ))) 835 835 836 -[[image:image-20220602165351-6.png]] 874 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-6.png?rev=1.1||alt="image-20220602165351-6.png"]] 837 837 838 -[[image:image-20220602165351-7.png]] 876 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-7.png?rev=1.1||alt="image-20220602165351-7.png"]] 839 839 840 840 841 841 ... ... @@ -903,7 +903,7 @@ 903 903 ))) 904 904 905 905 ((( 906 -The use of this command please see: [[Compose Uplink payload>> ||anchor="H3.3.4Composetheuplinkpayload"]]944 +The use of this command please see: [[Compose Uplink payload>>path:#H3.3.4Composetheuplinkpayload]] 907 907 ))) 908 908 909 909 * ((( ... ... @@ -954,7 +954,7 @@ 954 954 ))) 955 955 956 956 ((( 957 -No AT Command for this, user can press the [[ACT button>> ||anchor="H3.7Buttons"]] for 1 second for the same.995 +No AT Command for this, user can press the [[ACT button>>path:#H3.7Buttons]] for 1 second for the same. 958 958 ))) 959 959 960 960 ((( ... ... @@ -1002,7 +1002,7 @@ 1002 1002 The uplink screen shot is: 1003 1003 ))) 1004 1004 1005 -[[image:1654160691922-496.png]] 1043 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654160691922-496.png?rev=1.1||alt="1654160691922-496.png"]] 1006 1006 1007 1007 1008 1008 * ((( ... ... @@ -1103,7 +1103,7 @@ 1103 1103 RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN. 1104 1104 ))) 1105 1105 1106 -[[image:image-20220602171200-8.png||height="567" width="1007"]] 1144 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-8.png?width=1007&height=567&rev=1.1||alt="image-20220602171200-8.png" height="567" width="1007"]] 1107 1107 1108 1108 ((( 1109 1109 To enable the listening mode, use can run the command AT+RXMODE. ... ... @@ -1114,29 +1114,29 @@ 1114 1114 ))) 1115 1115 1116 1116 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1117 -|=(% style="width: 1 00px;" %)(((1118 -**Command example** 1119 -)))|=(% style="width: 400px;" %)(((1155 +|=(% style="width: 161px;" %)((( 1156 +**Command example:** 1157 +)))|=(% style="width: 337px;" %)((( 1120 1120 **Function** 1121 1121 ))) 1122 -|(% style="width:1 00px" %)(((1160 +|(% style="width:161px" %)((( 1123 1123 AT+RXMODE=1,10 1124 -)))|(% style="width: 400px" %)(((1162 +)))|(% style="width:337px" %)((( 1125 1125 Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1126 1126 ))) 1127 -|(% style="width:1 00px" %)(((1165 +|(% style="width:161px" %)((( 1128 1128 AT+RXMODE=2,500 1129 -)))|(% style="width: 400px" %)(((1167 +)))|(% style="width:337px" %)((( 1130 1130 Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1131 1131 ))) 1132 -|(% style="width:1 00px" %)(((1170 +|(% style="width:161px" %)((( 1133 1133 AT+RXMODE=0,0 1134 -)))|(% style="width: 400px" %)(((1172 +)))|(% style="width:337px" %)((( 1135 1135 Disable listening mode. This is the default settings. 1136 1136 ))) 1137 -|(% style="width:1 00px" %)(((1175 +|(% style="width:161px" %)((( 1138 1138 1139 -)))|(% style="width: 400px" %)(((1177 +)))|(% style="width:337px" %)((( 1140 1140 A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1141 1141 ))) 1142 1142 ... ... @@ -1177,7 +1177,7 @@ 1177 1177 ))) 1178 1178 1179 1179 ((( 1180 -[[image:image-20220602171200-9.png]] 1218 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-9.png?rev=1.1||alt="image-20220602171200-9.png"]] 1181 1181 ))) 1182 1182 1183 1183 ((( ... ... @@ -1185,10 +1185,8 @@ 1185 1185 ))) 1186 1186 1187 1187 ((( 1188 -((( 1189 1189 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1190 1190 ))) 1191 -))) 1192 1192 1193 1193 1194 1194 == 3.7 Buttons == ... ... @@ -1195,24 +1195,23 @@ 1195 1195 1196 1196 1197 1197 (% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1198 -|=(% style="width: 50px;" %)**Button**|=(% style="width: 361px;" %)**Feature**1199 -|(% style="width: 50px" %)**ACT**|(% style="width:361px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**1200 -|(% style="width: 50px" %)**RST**|(% style="width:361px" %)Reboot RS4851201 -|(% style="width: 50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]1234 +|=(% style="width: 30px;" %)**Button**|=(% style="width: 355px;" %)**Feature** 1235 +|=(% style="width: 30px;" %)**ACT**|(% style="width:355px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 1236 +|=(% style="width: 30px;" %)**RST**|(% style="width:355px" %)Reboot RS485 1237 +|=(% style="width: 30px;" %)**PRO**|(% style="width:355px" %)Use for upload image, see [[How to Update Image>>path:#H6.1Howtoupgradetheimage3F]] 1202 1202 1203 1203 1204 1204 == 3.8 LEDs == 1205 1205 1242 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %) 1243 +|=(% style="width: 30px;" %)**LEDs**|=(% style="width: 400px;" %)**Feature** 1244 +|(% style="width:30px" %)**PWR**|=(% style="width: 400px;" %)Always on if there is power 1245 +|(% style="width:30px" %)**SYS**|=(% style="width: 400px;" %)After device is powered on, the SYS will (% style="color:green" %)fast blink in GREEN (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)on GREEN for 5 seconds(%%). SYS will (% style="color:green" %)blink Blue(%%) on every upload and (% style="color:green" %)blink Green(%%) once receive a downlink message. 1206 1206 1207 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1208 -|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature** 1209 -|**PWR**|Always on if there is power 1210 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1211 1211 1212 - 1213 1213 = 4. Case Study = 1214 1214 1215 -User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>> doc:Main.Application\:Communicate.WebHome]]1250 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>path:/xwiki/bin/view/Main/Application%20Note%20%3A%20Communicate%20with%20Different%20Sensors%20-----%20RS485-LN%20%20RS485-BL/]] 1216 1216 1217 1217 1218 1218 = 5. Use AT Command = ... ... @@ -1223,7 +1223,7 @@ 1223 1223 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1224 1224 ))) 1225 1225 1226 -[[image:1654162355560-817.png]] 1261 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162355560-817.png?rev=1.1||alt="1654162355560-817.png"]] 1227 1227 1228 1228 1229 1229 ((( ... ... @@ -1230,11 +1230,11 @@ 1230 1230 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1231 1231 ))) 1232 1232 1233 -[[image:1654162368066-342.png]] 1268 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162368066-342.png?rev=1.1||alt="1654162368066-342.png"]] 1234 1234 1235 1235 1236 1236 ((( 1237 -More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1272 +More detail AT Command manual can be found at [[AT Command Manual>>url:https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1238 1238 ))) 1239 1239 1240 1240 ... ... @@ -1261,9 +1261,7 @@ 1261 1261 ))) 1262 1262 1263 1263 1264 -((( 1265 1265 If device already joined network: 1266 -))) 1267 1267 1268 1268 (% class="box infomessage" %) 1269 1269 ((( ... ... @@ -1302,14 +1302,12 @@ 1302 1302 1303 1303 (% style="color:red" %)**Note:** 1304 1304 1305 -((( 1306 1306 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1307 1307 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1308 1308 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1309 1309 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1310 -))) 1311 1311 1312 -[[image:1654162478620-421.png]] 1343 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162478620-421.png?rev=1.1||alt="1654162478620-421.png"]] 1313 1313 1314 1314 1315 1315 = 6. FAQ = ... ... @@ -1316,69 +1316,49 @@ 1316 1316 1317 1317 == 6.1 How to upgrade the image? == 1318 1318 1319 -((( 1320 1320 The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to: 1321 -))) 1322 1322 1323 -* ((( 1324 -Support new features 1325 -))) 1326 -* ((( 1327 -For bug fix 1328 -))) 1329 -* ((( 1330 -Change LoRaWAN bands. 1331 -))) 1352 +* Support new features 1353 +* For bug fix 1354 +* Change LoRaWAN bands. 1332 1332 1333 -((( 1334 1334 Below shows the hardware connection for how to upload an image to RS485-LN: 1335 -))) 1336 1336 1337 -[[image:1654162535040-878.png]] 1358 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162535040-878.png?rev=1.1||alt="1654162535040-878.png"]] 1338 1338 1339 -((( 1340 1340 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1341 -))) 1342 1342 1343 -((( 1344 1344 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1345 -))) 1346 1346 1347 -((( 1348 1348 **Step3: **Open flashloader; choose the correct COM port to update. 1349 -))) 1350 1350 1351 1351 ((( 1352 -((( 1353 -((( 1354 1354 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 1355 1355 ))) 1356 -))) 1357 -))) 1358 1358 1359 1359 1360 -[[image:image-20220602175818-12.png]] 1371 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175818-12.png?rev=1.1||alt="image-20220602175818-12.png"]] 1361 1361 1362 1362 1363 -[[image:image-20220602175848-13.png]] 1374 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175848-13.png?rev=1.1||alt="image-20220602175848-13.png"]] 1364 1364 1365 1365 1366 -[[image:image-20220602175912-14.png]] 1377 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175912-14.png?rev=1.1||alt="image-20220602175912-14.png"]] 1367 1367 1368 1368 1369 1369 **Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1370 1370 1371 -[[image:image-20220602175638-10.png]] 1382 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175638-10.png?rev=1.1||alt="image-20220602175638-10.png"]] 1372 1372 1373 1373 1374 1374 == 6.2 How to change the LoRa Frequency Bands/Region? == 1375 1375 1376 -User can follow the introduction for [[how to upgrade image>> ||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.1387 +User can follow the introduction for [[how to upgrade image>>path:#H6.1Howtoupgradetheimage3F]]. When download the images, choose the required image file for download. 1377 1377 1378 1378 1379 1379 == 6.3 How many RS485-Slave can RS485-BL connects? == 1380 1380 1381 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>> ||anchor="H3.3.3Configurereadcommandsforeachsampling"]].1392 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#H3.3.3Configurereadcommandsforeachsampling]]. 1382 1382 1383 1383 1384 1384 == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? == ... ... @@ -1385,7 +1385,7 @@ 1385 1385 1386 1386 When user need to use with ChirpStack or TTI. Please set AT+RPL=4. 1387 1387 1388 -Detail info check this link: [[Set Packet Receiving Response Level>> doc:Main.End.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]1399 +Detail info check this link: [[Set Packet Receiving Response Level>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.23SetPacketReceivingResponseLevel]] 1389 1389 1390 1390 1391 1391 = 7. Trouble Shooting = ... ... @@ -1392,12 +1392,12 @@ 1392 1392 1393 1393 == 7.1 Downlink doesn’t work, how to solve it? == 1394 1394 1395 -Please see this link for debug: [[LoRaWAN Communication Debug>> doc:Main.LoRaWAN.WebHome]]1406 +Please see this link for debug: [[LoRaWAN Communication Debug>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/]] 1396 1396 1397 1397 1398 1398 == 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? == 1399 1399 1400 -It might about the channels mapping. Please see for detail: [[Notice of Frequency band>> doc:Main.LoRaWAN.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]1411 +It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]] 1401 1401 1402 1402 1403 1403 = 8. Order Info =