<
From version < 60.12 >
edited by Xiaoling
on 2022/06/14 11:26
To version < 61.5 >
edited by Xiaoling
on 2022/06/14 11:33
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -96,8 +96,6 @@
96 96  * Packet engine up to 256 bytes with CRC
97 97  
98 98  
99 -
100 -
101 101  == 1.3 Features ==
102 102  
103 103  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -109,6 +109,7 @@
109 109  * Support Modbus protocol
110 110  * Support Interrupt uplink (Since hardware version v1.2)
111 111  
110 +
112 112  == 1.4 Applications ==
113 113  
114 114  * Smart Buildings & Home Automation
... ... @@ -118,6 +118,7 @@
118 118  * Smart Cities
119 119  * Smart Factory
120 120  
120 +
121 121  == 1.5 Firmware Change log ==
122 122  
123 123  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -320,6 +320,7 @@
320 320  )))
321 321  
322 322  
323 +
323 323  === 3.3.2 Configure sensors ===
324 324  
325 325  (((
... ... @@ -345,6 +345,7 @@
345 345  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
346 346  
347 347  
349 +
348 348  === 3.3.3 Configure read commands for each sampling ===
349 349  
350 350  (((
... ... @@ -368,7 +368,6 @@
368 368  
369 369  After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**.
370 370  
371 -
372 372  Below are examples for the how above AT Commands works.
373 373  
374 374  
... ... @@ -495,6 +495,7 @@
495 495  [[image:1654157178836-407.png]]
496 496  
497 497  
499 +
498 498  === 3.3.5 Uplink on demand ===
499 499  
500 500  Except uplink periodically, RS485-LN is able to uplink on demand. The server send downlink command to RS485-LN and RS485 will uplink data base on the command.
... ... @@ -566,7 +566,7 @@
566 566  
567 567  
568 568  
569 -==== **RS485 Debug Command** ====
571 +==== (% style="color:#037691" %)**RS485 Debug Command**(%%) ====
570 570  
571 571  (((
572 572  This command is used to configure the RS485 devices; they won’t be used during sampling.
... ... @@ -573,15 +573,12 @@
573 573  )))
574 574  
575 575  * (((
576 -**AT Command**
577 -)))
578 +(% style="color:#037691" %)**AT Command**
578 578  
579 -(% class="box infomessage" %)
580 -(((
581 -(((
582 582  **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
581 +
582 +
583 583  )))
584 -)))
585 585  
586 586  (((
587 587  m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
... ... @@ -588,7 +588,7 @@
588 588  )))
589 589  
590 590  * (((
591 -**Downlink Payload**
590 +(% style="color:#037691" %)**Downlink Payload**
592 592  )))
593 593  
594 594  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0