Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -RS485-LN – RS485 to LoRaWAN Converter User Manual1 +RS485-LN – RS485 to LoRaWAN Converter - Content
-
... ... @@ -1,8 +1,9 @@ 1 1 (% style="text-align:center" %) 2 -[[image:1653266934636-343.png||height="385" width="385"]] 2 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653266934636-343.png?width=385&height=385&rev=1.1||alt="1653266934636-343.png" height="385" width="385"]] 3 3 4 4 5 5 6 +**RS485-LN – RS485 to LoRaWAN Converter User Manual** 6 6 7 7 8 8 ... ... @@ -9,7 +9,59 @@ 9 9 10 10 **Table of Contents:** 11 11 12 -{{toc/}} 13 +* [[1.Introduction>>path:#H1.Introduction]] 14 +** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>path:#H1.1A0WhatisRS485-LNRS485toLoRaWANConverter]] 15 +** [[1.2 Specifications>>path:#H1.2A0Specifications]] 16 +** [[1.3 Features>>path:#H1.3Features]] 17 +** [[1.4 Applications>>path:#H1.4A0Applications]] 18 +** [[1.5 Firmware Change log>>path:#H1.5A0FirmwareChangelog]] 19 +** [[1.6 Hardware Change log>>path:#H1.6HardwareChangelog]] 20 +* [[2. Power ON Device>>path:#H2.PowerONDevice]] 21 +* [[3. Operation Mode>>path:#H3.A0OperationMode]] 22 +** [[3.1 How it works?>>path:#H3.1Howitworks3F]] 23 +** [[3.2 Example to join LoRaWAN network>>path:#H3.2ExampletojoinLoRaWANnetwork]] 24 +** [[3.3 Configure Commands to read data>>path:#H3.3ConfigureCommandstoreaddata]] 25 +*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>path:#H3.3.1onfigureUARTsettingsforRS485orTTLcommunication]] 26 +*** [[3.3.2 Configure sensors>>path:#H3.3.2Configuresensors]] 27 +*** [[3.3.3 Configure read commands for each sampling>>path:#H3.3.3Configurereadcommandsforeachsampling]] 28 +*** [[3.3.4 Compose the uplink payload>>path:#H3.3.4Composetheuplinkpayload]] 29 +*** [[3.3.5 Uplink on demand>>path:#H3.3.5Uplinkondemand]] 30 +*** [[3.3.6 Uplink on Interrupt>>path:#H3.3.6UplinkonInterrupt]] 31 +** [[3.4 Uplink Payload>>path:#H3.4UplinkPayload]] 32 +** [[3.5 Configure RS485-BL via AT or Downlink>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] 33 +*** [[3.5.1 Common Commands>>path:#H3.5.1CommonCommands]] 34 +*** [[3.5.2 Sensor related commands>>path:#H3.5.2Sensorrelatedcommands]] 35 +*** [[3.5.3 Sensor related commands>>path:#H3.5.3A0Sensorrelatedcommands]] 36 +**** [[RS485 Debug Command>>path:#HRS485DebugCommand]] 37 +**** [[Set Payload version>>path:#HSetPayloadversion]] 38 +**** [[Set RS485 Sampling Commands>>path:#HSetRS485SamplingCommands]] 39 +**** [[Fast command to handle MODBUS device>>path:#HFastcommandtohandleMODBUSdevice]] 40 +**** [[RS485 command timeout>>path:#HRS485commandtimeout]] 41 +**** [[Uplink payload mode>>path:#HUplinkpayloadmode]] 42 +**** [[Manually trigger an Uplink>>path:#HManuallytriggeranUplink]] 43 +**** [[Clear RS485 Command>>path:#HClearRS485Command]] 44 +**** [[Set Serial Communication Parameters>>path:#HSetSerialCommunicationParameters]] 45 +** [[3.6 Listening mode for RS485 network>>path:#H3.6A0ListeningmodeforRS485network]] 46 +** [[3.7 Buttons>>path:#H3.7Buttons]] 47 +** [[3.8 LEDs>>path:#H3.8LEDs]] 48 +* [[4. Case Study>>path:#H4.CaseStudy]] 49 +* [[5. Use AT Command>>path:#H5.UseATCommand]] 50 +** [[5.1 Access AT Command>>path:#H5.1AccessATCommand]] 51 +** [[5.2 Common AT Command Sequence>>path:#H5.2CommonATCommandSequence]] 52 +*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>path:#H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829]] 53 +*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>path:#H5.5.2Single-channelABPmode28UsewithLG012FLG0229]] 54 +* [[6. FAQ>>path:#H6.FAQ]] 55 +** [[6.1 How to upgrade the image?>>path:#H6.1Howtoupgradetheimage3F]] 56 +** [[6.2 How to change the LoRa Frequency Bands/Region?>>path:#H6.2HowtochangetheLoRaFrequencyBands2FRegion3F]] 57 +** [[6.3 How many RS485-Slave can RS485-BL connects?>>path:#H6.3HowmanyRS485-SlavecanRS485-BLconnects3F]] 58 +** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>path:#H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F]] 59 +* [[7. Trouble Shooting>>path:#H7.TroubleShooting]] 60 +** [[7.1 Downlink doesn’t work, how to solve it?>>path:#H7.1Downlinkdoesn2019twork2Chowtosolveit3F]] 61 +** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>path:#H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F]] 62 +* [[8. Order Info>>path:#H8.OrderInfo]] 63 +* [[9.Packing Info>>path:#H9.PackingInfo]] 64 +* [[10. FCC Caution for RS485LN-US915>>path:#H10.FCCCautionforRS485LN-US915]] 65 +* [[11. Support>>path:#H11.Support]] 13 13 14 14 15 15 ... ... @@ -24,8 +24,6 @@ 24 24 ((( 25 25 ((( 26 26 ((( 27 - 28 - 29 29 The Dragino RS485-LN is a (% style="color:blue" %)**RS485 to LoRaWAN Converter**(%%). It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost. 30 30 ))) 31 31 ))) ... ... @@ -49,13 +49,11 @@ 49 49 50 50 ((( 51 51 (% style="color:blue" %)**Demo Dashboard for RS485-LN**(%%) connect to two energy meters: [[https:~~/~~/app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a>>url:https://app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a]] 52 - 53 - 54 54 ))) 55 55 ))) 56 56 ))) 57 57 58 -[[image:1653267211009-519.png||height="419" width="724"]] 107 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653267211009-519.png?width=724&height=419&rev=1.1||alt="1653267211009-519.png" height="419" width="724"]] 59 59 60 60 61 61 == 1.2 Specifications == ... ... @@ -95,9 +95,6 @@ 95 95 * Automatic RF Sense and CAD with ultra-fast AFC. 96 96 * Packet engine up to 256 bytes with CRC 97 97 98 - 99 - 100 - 101 101 == 1.3 Features == 102 102 103 103 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -151,7 +151,7 @@ 151 151 Once there is power, the RS485-LN will be on. 152 152 ))) 153 153 154 -[[image:1653268091319-405.png]] 200 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268091319-405.png?rev=1.1||alt="1653268091319-405.png"]] 155 155 156 156 157 157 ))) ... ... @@ -172,7 +172,7 @@ 172 172 173 173 Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 174 174 175 -[[image:1653268155545-638.png||height="334" width="724"]] 221 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268155545-638.png?width=724&height=334&rev=1.1||alt="1653268155545-638.png" height="334" width="724"]] 176 176 177 177 178 178 ((( ... ... @@ -184,15 +184,14 @@ 184 184 485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively. 185 185 ))) 186 186 187 -[[image:1653268227651-549.png||height="592" width="720"]] 233 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268227651-549.png?width=720&height=592&rev=1.1||alt="1653268227651-549.png" height="592" width="720"]] 188 188 189 - 190 190 ((( 191 -The LG308 is already set to connect to [[TTN V3 network >> path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:236 +The LG308 is already set to connect to (% class="wikiinternallink" %)[[TTN V3 network >>url:https://www.thethingsnetwork.org/]](%%). So what we need to now is only configure the TTN V3: 192 192 ))) 193 193 194 194 ((( 195 - (% style="color:blue" %)**Step 1**(%%): Create a device in TTN V3 with the OTAA keys from RS485-LN.240 +**Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-LN. 196 196 ))) 197 197 198 198 ((( ... ... @@ -200,9 +200,8 @@ 200 200 ))) 201 201 ))) 202 202 203 -[[image:1652953462722-299.png]] 248 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953462722-299.png?rev=1.1||alt="1652953462722-299.png"]] 204 204 205 - 206 206 ((( 207 207 ((( 208 208 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot: ... ... @@ -209,34 +209,32 @@ 209 209 ))) 210 210 211 211 ((( 212 - **Add APP EUI in the application.**256 +Add APP EUI in the application. 213 213 ))) 214 214 ))) 215 215 216 -[[image:image-20220519174512-1.png]] 260 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-1.png?rev=1.1||alt="image-20220519174512-1.png"]] 217 217 218 -[[image:image-20220519174512-2.png||height="323" width="720"]] 262 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-2.png?width=720&height=323&rev=1.1||alt="image-20220519174512-2.png" height="323" width="720"]] 219 219 220 -[[image:image-20220519174512-3.png||height="556" width="724"]] 264 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-3.png?width=724&height=556&rev=1.1||alt="image-20220519174512-3.png" height="556" width="724"]] 221 221 222 -[[image:image-20220519174512-4.png]] 266 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-4.png?rev=1.1||alt="image-20220519174512-4.png"]] 223 223 224 224 You can also choose to create the device manually. 225 225 226 -[[image:1652953542269-423.png||height="710" width="723"]] 270 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953542269-423.png?width=723&height=710&rev=1.1||alt="1652953542269-423.png" height="710" width="723"]] 227 227 272 +Add APP KEY and DEV EUI 228 228 274 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953553383-907.png?width=724&height=514&rev=1.1||alt="1652953553383-907.png" height="514" width="724"]] 229 229 230 -**Add APP KEY and DEV EUI** 231 231 232 -[[image:1652953553383-907.png||height="514" width="724"]] 233 - 234 - 235 235 ((( 236 - (% style="color:blue" %)**Step 2**(%%): Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.278 +**Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 237 237 ))) 238 238 239 -[[image:1652953568895-172.png||height="232" width="724"]] 281 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953568895-172.png?width=724&height=232&rev=1.1||alt="1652953568895-172.png" height="232" width="724"]] 240 240 241 241 242 242 == 3.3 Configure Commands to read data == ... ... @@ -243,15 +243,11 @@ 243 243 244 244 ((( 245 245 ((( 246 -((( 247 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-LNviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 288 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 248 248 ))) 249 -))) 250 250 251 251 ((( 252 -((( 253 253 (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 254 -))) 255 255 256 256 257 257 ))) ... ... @@ -319,7 +319,6 @@ 319 319 ))) 320 320 ))) 321 321 322 - 323 323 === 3.3.2 Configure sensors === 324 324 325 325 ((( ... ... @@ -331,20 +331,13 @@ 331 331 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 332 332 |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 333 333 |AT+CFGDEV|(% style="width:110px" %)((( 334 -((( 335 335 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 336 -))) 337 337 338 -((( 339 339 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 340 -))) 341 341 342 -((( 343 343 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 344 -))) 345 345 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 346 346 347 - 348 348 === 3.3.3 Configure read commands for each sampling === 349 349 350 350 ((( ... ... @@ -357,7 +357,7 @@ 357 357 During each sampling, the RS485-LN can support 15 commands to read sensors. And combine the return to one or several uplink payloads. 358 358 359 359 360 - (% style="color:#037691" %)**Each RS485 commands include two parts:**390 +**Each RS485 commands include two parts:** 361 361 362 362 ~1. What commands RS485-LN will send to the RS485 sensors. There are total 15 commands from **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF**. All commands are of same grammar. 363 363 ... ... @@ -372,11 +372,11 @@ 372 372 Below are examples for the how above AT Commands works. 373 373 374 374 375 - (% style="color:#037691" %)**AT+COMMANDx**(%%)**: **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is:405 +**AT+COMMANDx : **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is: 376 376 377 377 (% border="1" style="background-color:#4bacc6; color:white; width:499px" %) 378 378 |(% style="width:496px" %)((( 379 - (% style="color:#037691" %)**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**409 +**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 380 380 381 381 **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent** 382 382 ... ... @@ -388,7 +388,7 @@ 388 388 In the RS485-LN, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same. 389 389 390 390 391 - (% style="color:#037691" %)**AT+DATACUTx**(%%)**: **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.421 +**AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes. 392 392 393 393 (% border="1" style="background-color:#4bacc6; color:white; width:510px" %) 394 394 |(% style="width:510px" %)((( ... ... @@ -401,21 +401,20 @@ 401 401 402 402 **Examples:** 403 403 404 -* (% style="color:#037691" %)**Grab bytes**434 +* Grab bytes: 405 405 406 -[[image:image-20220602153621-1.png]] 436 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-1.png?rev=1.1||alt="image-20220602153621-1.png"]] 407 407 408 408 409 -* (% style="color:#037691" %)**Grab a section**439 +* Grab a section. 410 410 411 -[[image:image-20220602153621-2.png]] 441 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-2.png?rev=1.1||alt="image-20220602153621-2.png"]] 412 412 413 413 414 -* (% style="color:#037691" %)**Grab different sections**444 +* Grab different sections. 415 415 416 -[[image:image-20220602153621-3.png]] 446 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-3.png?rev=1.1||alt="image-20220602153621-3.png"]] 417 417 418 - 419 419 420 420 ))) 421 421 ... ... @@ -449,7 +449,7 @@ 449 449 Where PAYVER is defined by AT+PAYVER, below is an example screen shot. 450 450 ))) 451 451 452 -[[image:1653269759169-150.png||height="513" width="716"]] 481 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653269759169-150.png?width=716&height=513&rev=1.1||alt="1653269759169-150.png" height="513" width="716"]] 453 453 454 454 455 455 (% style="color:#037691" %)**Examples: AT+DATAUP=1** ... ... @@ -467,7 +467,7 @@ 467 467 1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) 468 468 1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes 469 469 470 -[[image:image-20220602155039-4.png]] 499 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602155039-4.png?rev=1.1||alt="image-20220602155039-4.png"]] 471 471 472 472 473 473 So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA ... ... @@ -492,7 +492,7 @@ 492 492 493 493 Below are the uplink payloads: 494 494 495 -[[image:1654157178836-407.png]] 524 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157178836-407.png?rev=1.1||alt="1654157178836-407.png"]] 496 496 497 497 498 498 === 3.3.5 Uplink on demand === ... ... @@ -511,7 +511,7 @@ 511 511 512 512 RS485-LN support external Interrupt uplink since hardware v1.2 release. 513 513 514 -[[image:1654157342174-798.png]] 543 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157342174-798.png?rev=1.1||alt="1654157342174-798.png"]] 515 515 516 516 Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet. 517 517 ... ... @@ -519,12 +519,12 @@ 519 519 == 3.4 Uplink Payload == 520 520 521 521 522 -[[image:image-20220606110929-1.png]] 551 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220606110929-1.png?rev=1.1||alt="image-20220606110929-1.png"]] 523 523 524 524 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 525 525 526 526 527 -== 3.5 Configure RS485-L Nvia AT or Downlink ==556 +== 3.5 Configure RS485-BL via AT or Downlink == 528 528 529 529 ((( 530 530 User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands ... ... @@ -535,7 +535,7 @@ 535 535 ))) 536 536 537 537 * ((( 538 -(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>> doc:Main.End.WebHome]]567 +(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 539 539 ))) 540 540 541 541 * ((( ... ... @@ -549,7 +549,7 @@ 549 549 550 550 === 3.5.1 Common Commands === 551 551 552 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>> doc:Main.End.WebHome]]581 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 553 553 554 554 555 555 === 3.5.2 Sensor related commands === ... ... @@ -556,7 +556,7 @@ 556 556 557 557 Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server. 558 558 559 -[[image:image-20220602163333-5.png||height="263" width="1160"]] 588 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602163333-5.png?width=1160&height=263&rev=1.1||alt="image-20220602163333-5.png" height="263" width="1160"]] 560 560 561 561 The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable) 562 562 ... ... @@ -681,7 +681,7 @@ 681 681 ))) 682 682 683 683 ((( 684 - [[image:1654159460680-153.png]] 713 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654159460680-153.png?rev=1.1||alt="1654159460680-153.png"]] 685 685 ))) 686 686 687 687 ... ... @@ -690,7 +690,7 @@ 690 690 ==== **Set Payload version** ==== 691 691 692 692 ((( 693 -This is the first byte of the uplink payload. RS485-L Ncan connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.722 +This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 694 694 ))) 695 695 696 696 * ((( ... ... @@ -726,7 +726,7 @@ 726 726 ))) 727 727 728 728 ((( 729 -These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>> ||anchor="H3.3.3Configurereadcommandsforeachsampling"]].758 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#H3.3.3Configurereadcommandsforeachsampling]]. 730 730 ))) 731 731 732 732 ((( ... ... @@ -788,7 +788,7 @@ 788 788 XX XX XX XX: AT+COMMAND or AT+DATACUT command 789 789 ))) 790 790 * ((( 791 -YY: If YY=0, RS485-L Nwill execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.820 +YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 792 792 ))) 793 793 794 794 ((( ... ... @@ -842,9 +842,9 @@ 842 842 AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 843 843 ))) 844 844 845 -[[image:image-20220602165351-6.png]] 874 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-6.png?rev=1.1||alt="image-20220602165351-6.png"]] 846 846 847 -[[image:image-20220602165351-7.png]] 876 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-7.png?rev=1.1||alt="image-20220602165351-7.png"]] 848 848 849 849 850 850 ... ... @@ -912,7 +912,7 @@ 912 912 ))) 913 913 914 914 ((( 915 -The use of this command please see: [[Compose Uplink payload>> ||anchor="H3.3.4Composetheuplinkpayload"]]944 +The use of this command please see: [[Compose Uplink payload>>path:#H3.3.4Composetheuplinkpayload]] 916 916 ))) 917 917 918 918 * ((( ... ... @@ -963,7 +963,7 @@ 963 963 ))) 964 964 965 965 ((( 966 -No AT Command for this, user can press the [[ACT button>> ||anchor="H3.7Buttons"]] for 1 second for the same.995 +No AT Command for this, user can press the [[ACT button>>path:#H3.7Buttons]] for 1 second for the same. 967 967 ))) 968 968 969 969 ((( ... ... @@ -1011,7 +1011,7 @@ 1011 1011 The uplink screen shot is: 1012 1012 ))) 1013 1013 1014 -[[image:1654160691922-496.png]] 1043 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654160691922-496.png?rev=1.1||alt="1654160691922-496.png"]] 1015 1015 1016 1016 1017 1017 * ((( ... ... @@ -1112,7 +1112,7 @@ 1112 1112 RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN. 1113 1113 ))) 1114 1114 1115 -[[image:image-20220602171200-8.png||height="567" width="1007"]] 1144 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-8.png?width=1007&height=567&rev=1.1||alt="image-20220602171200-8.png" height="567" width="1007"]] 1116 1116 1117 1117 ((( 1118 1118 To enable the listening mode, use can run the command AT+RXMODE. ... ... @@ -1123,29 +1123,29 @@ 1123 1123 ))) 1124 1124 1125 1125 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1126 -|=(% style="width: 1 00px;" %)(((1127 -**Command example** 1128 -)))|=(% style="width: 400px;" %)(((1155 +|=(% style="width: 161px;" %)((( 1156 +**Command example:** 1157 +)))|=(% style="width: 337px;" %)((( 1129 1129 **Function** 1130 1130 ))) 1131 -|(% style="width:1 00px" %)(((1160 +|(% style="width:161px" %)((( 1132 1132 AT+RXMODE=1,10 1133 -)))|(% style="width: 400px" %)(((1162 +)))|(% style="width:337px" %)((( 1134 1134 Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1135 1135 ))) 1136 -|(% style="width:1 00px" %)(((1165 +|(% style="width:161px" %)((( 1137 1137 AT+RXMODE=2,500 1138 -)))|(% style="width: 400px" %)(((1167 +)))|(% style="width:337px" %)((( 1139 1139 Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1140 1140 ))) 1141 -|(% style="width:1 00px" %)(((1170 +|(% style="width:161px" %)((( 1142 1142 AT+RXMODE=0,0 1143 -)))|(% style="width: 400px" %)(((1172 +)))|(% style="width:337px" %)((( 1144 1144 Disable listening mode. This is the default settings. 1145 1145 ))) 1146 -|(% style="width:1 00px" %)(((1175 +|(% style="width:161px" %)((( 1147 1147 1148 -)))|(% style="width: 400px" %)(((1177 +)))|(% style="width:337px" %)((( 1149 1149 A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1150 1150 ))) 1151 1151 ... ... @@ -1186,7 +1186,7 @@ 1186 1186 ))) 1187 1187 1188 1188 ((( 1189 -[[image:image-20220602171200-9.png]] 1218 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-9.png?rev=1.1||alt="image-20220602171200-9.png"]] 1190 1190 ))) 1191 1191 1192 1192 ((( ... ... @@ -1194,10 +1194,8 @@ 1194 1194 ))) 1195 1195 1196 1196 ((( 1197 -((( 1198 1198 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1199 1199 ))) 1200 -))) 1201 1201 1202 1202 1203 1203 == 3.7 Buttons == ... ... @@ -1204,22 +1204,23 @@ 1204 1204 1205 1205 1206 1206 (% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1207 -|=(% style="width: 50px;" %)**Button**|=(% style="width: 361px;" %)**Feature**1208 -|(% style="width: 50px" %)**ACT**|(% style="width:361px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**1209 -|(% style="width: 50px" %)**RST**|(% style="width:361px" %)Reboot RS4851210 -|(% style="width: 50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]1234 +|=(% style="width: 30px;" %)**Button**|=(% style="width: 355px;" %)**Feature** 1235 +|=(% style="width: 30px;" %)**ACT**|(% style="width:355px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 1236 +|=(% style="width: 30px;" %)**RST**|(% style="width:355px" %)Reboot RS485 1237 +|=(% style="width: 30px;" %)**PRO**|(% style="width:355px" %)Use for upload image, see [[How to Update Image>>path:#H6.1Howtoupgradetheimage3F]] 1211 1211 1239 + 1212 1212 == 3.8 LEDs == 1213 1213 1242 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %) 1243 +|=(% style="width: 30px;" %)**LEDs**|=(% style="width: 400px;" %)**Feature** 1244 +|(% style="width:30px" %)**PWR**|=(% style="width: 400px;" %)Always on if there is power 1245 +|(% style="width:30px" %)**SYS**|=(% style="width: 400px;" %)After device is powered on, the SYS will (% style="color:green" %)fast blink in GREEN (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)on GREEN for 5 seconds(%%). SYS will (% style="color:green" %)blink Blue(%%) on every upload and (% style="color:green" %)blink Green(%%) once receive a downlink message. 1214 1214 1215 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1216 -|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature** 1217 -|**PWR**|Always on if there is power 1218 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1219 1219 1220 1220 = 4. Case Study = 1221 1221 1222 -User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>> doc:Main.Application\:Communicate.WebHome]]1250 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>path:/xwiki/bin/view/Main/Application%20Note%20%3A%20Communicate%20with%20Different%20Sensors%20-----%20RS485-LN%20%20RS485-BL/]] 1223 1223 1224 1224 1225 1225 = 5. Use AT Command = ... ... @@ -1227,21 +1227,21 @@ 1227 1227 == 5.1 Access AT Command == 1228 1228 1229 1229 ((( 1230 -RS485-L Nsupports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-LNto use AT command, as below.1258 +RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1231 1231 ))) 1232 1232 1233 -[[image:1654162355560-817.png]] 1261 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162355560-817.png?rev=1.1||alt="1654162355560-817.png"]] 1234 1234 1235 1235 1236 1236 ((( 1237 -In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-L N. The default password is 123456. Below is the output for reference:1265 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1238 1238 ))) 1239 1239 1240 -[[image:1654162368066-342.png]] 1268 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162368066-342.png?rev=1.1||alt="1654162368066-342.png"]] 1241 1241 1242 1242 1243 1243 ((( 1244 -More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1272 +More detail AT Command manual can be found at [[AT Command Manual>>url:https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1245 1245 ))) 1246 1246 1247 1247 ... ... @@ -1268,9 +1268,7 @@ 1268 1268 ))) 1269 1269 1270 1270 1271 -((( 1272 1272 If device already joined network: 1273 -))) 1274 1274 1275 1275 (% class="box infomessage" %) 1276 1276 ((( ... ... @@ -1309,14 +1309,12 @@ 1309 1309 1310 1310 (% style="color:red" %)**Note:** 1311 1311 1312 -((( 1313 1313 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1314 1314 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1315 1315 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1316 1316 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1317 -))) 1318 1318 1319 -[[image:1654162478620-421.png]] 1343 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162478620-421.png?rev=1.1||alt="1654162478620-421.png"]] 1320 1320 1321 1321 1322 1322 = 6. FAQ = ... ... @@ -1323,69 +1323,49 @@ 1323 1323 1324 1324 == 6.1 How to upgrade the image? == 1325 1325 1326 -((( 1327 1327 The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to: 1328 -))) 1329 1329 1330 -* ((( 1331 -Support new features 1332 -))) 1333 -* ((( 1334 -For bug fix 1335 -))) 1336 -* ((( 1337 -Change LoRaWAN bands. 1338 -))) 1352 +* Support new features 1353 +* For bug fix 1354 +* Change LoRaWAN bands. 1339 1339 1340 -((( 1341 1341 Below shows the hardware connection for how to upload an image to RS485-LN: 1342 -))) 1343 1343 1344 -[[image:1654162535040-878.png]] 1358 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162535040-878.png?rev=1.1||alt="1654162535040-878.png"]] 1345 1345 1346 -((( 1347 1347 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1348 -))) 1349 1349 1350 -((( 1351 1351 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1352 -))) 1353 1353 1354 -((( 1355 1355 **Step3: **Open flashloader; choose the correct COM port to update. 1356 -))) 1357 1357 1358 1358 ((( 1359 -((( 1360 -((( 1361 1361 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 1362 1362 ))) 1363 -))) 1364 -))) 1365 1365 1366 1366 1367 -[[image:image-20220602175818-12.png]] 1371 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175818-12.png?rev=1.1||alt="image-20220602175818-12.png"]] 1368 1368 1369 1369 1370 -[[image:image-20220602175848-13.png]] 1374 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175848-13.png?rev=1.1||alt="image-20220602175848-13.png"]] 1371 1371 1372 1372 1373 -[[image:image-20220602175912-14.png]] 1377 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175912-14.png?rev=1.1||alt="image-20220602175912-14.png"]] 1374 1374 1375 1375 1376 1376 **Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1377 1377 1378 -[[image:image-20220602175638-10.png]] 1382 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175638-10.png?rev=1.1||alt="image-20220602175638-10.png"]] 1379 1379 1380 1380 1381 1381 == 6.2 How to change the LoRa Frequency Bands/Region? == 1382 1382 1383 -User can follow the introduction for [[how to upgrade image>> ||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.1387 +User can follow the introduction for [[how to upgrade image>>path:#H6.1Howtoupgradetheimage3F]]. When download the images, choose the required image file for download. 1384 1384 1385 1385 1386 -== 6.3 How many RS485-Slave can RS485-L Nconnects? ==1390 +== 6.3 How many RS485-Slave can RS485-BL connects? == 1387 1387 1388 -The RS485-L Ncan support max 32 RS485 devices. Each uplink command of RS485-LNcan support max 16 different RS485 command. So RS485-LNcan support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].1392 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#H3.3.3Configurereadcommandsforeachsampling]]. 1389 1389 1390 1390 1391 1391 == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? == ... ... @@ -1392,7 +1392,7 @@ 1392 1392 1393 1393 When user need to use with ChirpStack or TTI. Please set AT+RPL=4. 1394 1394 1395 -Detail info check this link: [[Set Packet Receiving Response Level>> doc:Main.End.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]1399 +Detail info check this link: [[Set Packet Receiving Response Level>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.23SetPacketReceivingResponseLevel]] 1396 1396 1397 1397 1398 1398 = 7. Trouble Shooting = ... ... @@ -1399,12 +1399,12 @@ 1399 1399 1400 1400 == 7.1 Downlink doesn’t work, how to solve it? == 1401 1401 1402 -Please see this link for debug: [[LoRaWAN Communication Debug>> doc:Main.LoRaWAN.WebHome]]1406 +Please see this link for debug: [[LoRaWAN Communication Debug>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/]] 1403 1403 1404 1404 1405 1405 == 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? == 1406 1406 1407 -It might about the channels mapping. Please see for detail: [[Notice of Frequency band>> doc:Main.LoRaWAN.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]1411 +It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]] 1408 1408 1409 1409 1410 1410 = 8. Order Info =