Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -95,6 +95,7 @@ 95 95 * Automatic RF Sense and CAD with ultra-fast AFC. 96 96 * Packet engine up to 256 bytes with CRC 97 97 98 + 98 98 == 1.3 Features == 99 99 100 100 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -106,6 +106,7 @@ 106 106 * Support Modbus protocol 107 107 * Support Interrupt uplink (Since hardware version v1.2) 108 108 110 + 109 109 == 1.4 Applications == 110 110 111 111 * Smart Buildings & Home Automation ... ... @@ -115,6 +115,7 @@ 115 115 * Smart Cities 116 116 * Smart Factory 117 117 120 + 118 118 == 1.5 Firmware Change log == 119 119 120 120 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -317,6 +317,7 @@ 317 317 ))) 318 318 319 319 323 + 320 320 === 3.3.2 Configure sensors === 321 321 322 322 ((( ... ... @@ -342,6 +342,7 @@ 342 342 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 343 343 344 344 349 + 345 345 === 3.3.3 Configure read commands for each sampling === 346 346 347 347 ((( ... ... @@ -365,7 +365,6 @@ 365 365 366 366 After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**. 367 367 368 - 369 369 Below are examples for the how above AT Commands works. 370 370 371 371 ... ... @@ -492,6 +492,7 @@ 492 492 [[image:1654157178836-407.png]] 493 493 494 494 499 + 495 495 === 3.3.5 Uplink on demand === 496 496 497 497 Except uplink periodically, RS485-LN is able to uplink on demand. The server send downlink command to RS485-LN and RS485 will uplink data base on the command. ... ... @@ -563,7 +563,7 @@ 563 563 564 564 565 565 566 -==== **RS485 Debug Command** ==== 571 +==== (% style="color:#037691" %)**RS485 Debug Command**(%%) ==== 567 567 568 568 ((( 569 569 This command is used to configure the RS485 devices; they won’t be used during sampling. ... ... @@ -570,15 +570,12 @@ 570 570 ))) 571 571 572 572 * ((( 573 -**AT Command** 574 -))) 578 +(% style="color:#037691" %)**AT Command** 575 575 576 -(% class="box infomessage" %) 577 -((( 578 -((( 579 579 **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 581 + 582 + 580 580 ))) 581 -))) 582 582 583 583 ((( 584 584 m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command ... ... @@ -585,7 +585,7 @@ 585 585 ))) 586 586 587 587 * ((( 588 -**Downlink Payload** 590 +(% style="color:#037691" %)**Downlink Payload** 589 589 ))) 590 590 591 591 (((