From version < 60.11 >
edited by Xiaoling
on 2022/06/14 11:23
To version < 60.8 >
edited by Xiaoling
on 2022/06/14 11:14
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -69,11 +69,13 @@
69 69  ** Idle: 32mA@12v
70 70  ** 20dB Transmit: 65mA@12v
71 71  
72 +
72 72  **Interface for Model:**
73 73  
74 74  * RS485
75 75  * Power Input 7~~ 24V DC. 
76 76  
78 +
77 77  **LoRa Spec:**
78 78  
79 79  * Frequency Range:
... ... @@ -95,6 +95,8 @@
95 95  * Automatic RF Sense and CAD with ultra-fast AFC.
96 96  * Packet engine up to 256 bytes with CRC
97 97  
100 +
101 +
98 98  == 1.3 Features ==
99 99  
100 100  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -106,6 +106,8 @@
106 106  * Support Modbus protocol
107 107  * Support Interrupt uplink (Since hardware version v1.2)
108 108  
113 +
114 +
109 109  == 1.4 Applications ==
110 110  
111 111  * Smart Buildings & Home Automation
... ... @@ -115,6 +115,8 @@
115 115  * Smart Cities
116 116  * Smart Factory
117 117  
124 +
125 +
118 118  == 1.5 Firmware Change log ==
119 119  
120 120  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -241,7 +241,7 @@
241 241  (((
242 242  (((
243 243  (((
244 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-LNviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
252 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
245 245  )))
246 246  )))
247 247  
... ... @@ -317,6 +317,8 @@
317 317  )))
318 318  
319 319  
328 +
329 +
320 320  === 3.3.2 Configure sensors ===
321 321  
322 322  (((
... ... @@ -342,6 +342,8 @@
342 342  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
343 343  
344 344  
355 +
356 +
345 345  === 3.3.3 Configure read commands for each sampling ===
346 346  
347 347  (((
... ... @@ -354,7 +354,7 @@
354 354  During each sampling, the RS485-LN can support 15 commands to read sensors. And combine the return to one or several uplink payloads.
355 355  
356 356  
357 -(% style="color:#037691" %)**Each RS485 commands include two parts:**
369 +**Each RS485 commands include two parts:**
358 358  
359 359  ~1. What commands RS485-LN will send to the RS485 sensors. There are total 15 commands from **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF**. All commands are of same grammar.
360 360  
... ... @@ -369,11 +369,11 @@
369 369  Below are examples for the how above AT Commands works.
370 370  
371 371  
372 -(% style="color:#037691" %)**AT+COMMANDx **(%%)**: **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is:
384 +**AT+COMMANDx : **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is:
373 373  
374 374  (% border="1" style="background-color:#4bacc6; color:white; width:499px" %)
375 375  |(% style="width:496px" %)(((
376 -(% style="color:#037691" %)**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
388 +**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
377 377  
378 378  **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent**
379 379  
... ... @@ -385,7 +385,7 @@
385 385  In the RS485-LN, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same.
386 386  
387 387  
388 -(% style="color:#037691" %)**AT+DATACUTx **(%%)**: **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
400 +**AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
389 389  
390 390  (% border="1" style="background-color:#4bacc6; color:white; width:510px" %)
391 391  |(% style="width:510px" %)(((
... ... @@ -398,21 +398,20 @@
398 398  
399 399  **Examples:**
400 400  
401 -* (% style="color:#037691" %)**Grab bytes**
413 +* Grab bytes:
402 402  
403 403  [[image:image-20220602153621-1.png]]
404 404  
405 405  
406 -* (% style="color:#037691" %)**Grab a section**
418 +* Grab a section.
407 407  
408 408  [[image:image-20220602153621-2.png]]
409 409  
410 410  
411 -* (% style="color:#037691" %)**Grab different sections**
423 +* Grab different sections.
412 412  
413 413  [[image:image-20220602153621-3.png]]
414 414  
415 -
416 416  
417 417  )))
418 418  
... ... @@ -521,7 +521,7 @@
521 521  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
522 522  
523 523  
524 -== 3.5 Configure RS485-LN via AT or Downlink ==
535 +== 3.5 Configure RS485-BL via AT or Downlink ==
525 525  
526 526  (((
527 527  User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands
... ... @@ -687,7 +687,7 @@
687 687  ==== **Set Payload version** ====
688 688  
689 689  (((
690 -This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
701 +This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
691 691  )))
692 692  
693 693  * (((
... ... @@ -785,7 +785,7 @@
785 785  XX XX XX XX: AT+COMMAND or AT+DATACUT command
786 786  )))
787 787  * (((
788 -YY:  If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.
799 +YY:  If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.
789 789  )))
790 790  
791 791  (((
... ... @@ -1224,7 +1224,7 @@
1224 1224  == 5.1 Access AT Command ==
1225 1225  
1226 1226  (((
1227 -RS485-LN supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-LN to use AT command, as below.
1238 +RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1228 1228  )))
1229 1229  
1230 1230  [[image:1654162355560-817.png]]
... ... @@ -1231,7 +1231,7 @@
1231 1231  
1232 1232  
1233 1233  (((
1234 -In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-LN. The default password is 123456. Below is the output for reference:
1245 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1235 1235  )))
1236 1236  
1237 1237  [[image:1654162368066-342.png]]
... ... @@ -1380,9 +1380,9 @@
1380 1380  User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
1381 1381  
1382 1382  
1383 -== 6.3 How many RS485-Slave can RS485-LN connects? ==
1394 +== 6.3 How many RS485-Slave can RS485-BL connects? ==
1384 1384  
1385 -The RS485-LN can support max 32 RS485 devices. Each uplink command of RS485-LN can support max 16 different RS485 command. So RS485-LN can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1396 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1386 1386  
1387 1387  
1388 1388  == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0