Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -92,8 +92,6 @@ 92 92 * Automatic RF Sense and CAD with ultra-fast AFC. 93 93 * Packet engine up to 256 bytes with CRC 94 94 95 - 96 - 97 97 == 1.3 Features == 98 98 99 99 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -105,8 +105,6 @@ 105 105 * Support Modbus protocol 106 106 * Support Interrupt uplink (Since hardware version v1.2) 107 107 108 - 109 - 110 110 == 1.4 Applications == 111 111 112 112 * Smart Buildings & Home Automation ... ... @@ -116,8 +116,6 @@ 116 116 * Smart Cities 117 117 * Smart Factory 118 118 119 - 120 - 121 121 == 1.5 Firmware Change log == 122 122 123 123 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -327,19 +327,14 @@ 327 327 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 328 328 |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 329 329 |AT+CFGDEV|(% style="width:110px" %)((( 330 -((( 331 331 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 332 -))) 333 333 334 -((( 335 335 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 336 -))) 337 337 338 -((( 339 339 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 340 -))) 341 341 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 342 342 331 + 343 343 === 3.3.3 Configure read commands for each sampling === 344 344 345 345 ((( ... ... @@ -1203,6 +1203,7 @@ 1203 1203 |(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485 1204 1204 |(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1205 1205 1195 + 1206 1206 == 3.8 LEDs == 1207 1207 1208 1208 ... ... @@ -1211,6 +1211,7 @@ 1211 1211 |**PWR**|Always on if there is power 1212 1212 |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1213 1213 1204 + 1214 1214 = 4. Case Study = 1215 1215 1216 1216 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -1262,9 +1262,7 @@ 1262 1262 ))) 1263 1263 1264 1264 1265 -((( 1266 1266 If device already joined network: 1267 -))) 1268 1268 1269 1269 (% class="box infomessage" %) 1270 1270 ((( ... ... @@ -1303,12 +1303,10 @@ 1303 1303 1304 1304 (% style="color:red" %)**Note:** 1305 1305 1306 -((( 1307 1307 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1308 1308 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1309 1309 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1310 1310 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1311 -))) 1312 1312 1313 1313 [[image:1654162478620-421.png]] 1314 1314