27 +
28 +
28 28  The Dragino RS485-LN is a (% style="color:blue" %)**RS485 to LoRaWAN Converter**(%%). It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost.
29 29  )))
30 30  )))
... ... @@ -48,6 +48,8 @@
48 48  
49 49  (((
50 50  (% style="color:blue" %)**Demo Dashboard for RS485-LN**(%%) connect to two energy meters: [[https:~~/~~/app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a>>url:https://app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a]]
52 +
53 +
51 51  )))
52 52  )))
53 53  )))
... ... @@ -94,6 +94,7 @@
94 94  
95 95  
96 96  
100 +
97 97  == 1.3 Features ==
98 98  
99 99  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -105,8 +105,6 @@
105 105  * Support Modbus protocol
106 106  * Support Interrupt uplink (Since hardware version v1.2)
107 107  
108 -
109 -
110 110  == 1.4 Applications ==
111 111  
112 112  * Smart Buildings & Home Automation
... ... @@ -116,8 +116,6 @@
116 116  * Smart Cities
117 117  * Smart Factory
118 118  
119 -
120 -
121 121  == 1.5 Firmware Change log ==
122 122  
123 123  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -186,12 +186,13 @@
186 186  
187 187  [[image:1653268227651-549.png||height="592" width="720"]]
188 188  
189 +
189 189  (((
190 190  The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:
191 191  )))
192 192  
193 193  (((
194 -**Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-LN.
195 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN V3 with the OTAA keys from RS485-LN.
195 195  )))
196 196  
197 197  (((
... ... @@ -201,6 +201,7 @@
201 201  
202 202  [[image:1652953462722-299.png]]
203 203  
205 +
204 204  (((
205 205  (((
206 206  User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot:
... ... @@ -207,7 +207,7 @@
207 207  )))
208 208  
209 209  (((
210 -Add APP EUI in the application.
212 +**Add APP EUI in the application.**
211 211  )))
212 212  )))
213 213  
... ... @@ -223,13 +223,15 @@
223 223  
224 224  [[image:1652953542269-423.png||height="710" width="723"]]
225 225  
226 -Add APP KEY and DEV EUI
227 227  
229 +
230 +**Add APP KEY and DEV EUI**
231 +
228 228  [[image:1652953553383-907.png||height="514" width="724"]]
229 229  
230 230  
231 231  (((
232 -**Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
236 +(% style="color:blue" %)**Step 2**(%%): Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
233 233  )))
234 234  
235 235  [[image:1652953568895-172.png||height="232" width="724"]]
... ... @@ -240,7 +240,7 @@
240 240  (((
241 241  (((
242 242  (((
243 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
247 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-LNviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
244 244  )))
245 245  )))
246 246  
... ... @@ -315,6 +315,7 @@
315 315  )))
316 316  )))
317 317  
322 +
318 318  === 3.3.2 Configure sensors ===
319 319  
320 320  (((
... ... @@ -339,6 +339,7 @@
339 339  )))
340 340  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
341 341  
347 +
342 342  === 3.3.3 Configure read commands for each sampling ===
343 343  
344 344  (((
... ... @@ -351,7 +351,7 @@
351 351  During each sampling, the RS485-LN can support 15 commands to read sensors. And combine the return to one or several uplink payloads.
352 352  
353 353  
354 -**Each RS485 commands include two parts:**
360 +(% style="color:#037691" %)**Each RS485 commands include two parts:**
355 355  
356 356  ~1. What commands RS485-LN will send to the RS485 sensors. There are total 15 commands from **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF**. All commands are of same grammar.
357 357  
... ... @@ -366,11 +366,11 @@
366 366  Below are examples for the how above AT Commands works.
367 367  
368 368  
369 -**AT+COMMANDx : **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is:
375 +(% style="color:#037691" %)**AT+COMMANDx **(%%)**: **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is:
370 370  
371 371  (% border="1" style="background-color:#4bacc6; color:white; width:499px" %)
372 372  |(% style="width:496px" %)(((
373 -**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
379 +(% style="color:#037691" %)**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
374 374  
375 375  **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent**
376 376  
... ... @@ -382,7 +382,7 @@
382 382  In the RS485-LN, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same.
383 383  
384 384  
385 -**AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
391 +(% style="color:#037691" %)**AT+DATACUTx **(%%)**: **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
386 386  
387 387  (% border="1" style="background-color:#4bacc6; color:white; width:510px" %)
388 388  |(% style="width:510px" %)(((
... ... @@ -395,20 +395,21 @@
395 395  
396 396  **Examples:**
397 397  
398 -* Grab bytes:
404 +* (% style="color:#037691" %)**Grab bytes**
399 399  
400 400  [[image:image-20220602153621-1.png]]
401 401  
402 402  
403 -* Grab a section.
409 +* (% style="color:#037691" %)**Grab a section**
404 404  
405 405  [[image:image-20220602153621-2.png]]
406 406  
407 407  
408 -* Grab different sections.
414 +* (% style="color:#037691" %)**Grab different sections**
409 409  
410 410  [[image:image-20220602153621-3.png]]
411 411  
418 +
412 412  
413 413  )))
414 414  
... ... @@ -517,7 +517,7 @@
517 517  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
518 518  
519 519  
520 -== 3.5 Configure RS485-BL via AT or Downlink ==
527 +== 3.5 Configure RS485-LN via AT or Downlink ==
521 521  
522 522  (((
523 523  User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands
... ... @@ -683,7 +683,7 @@
683 683  ==== **Set Payload version** ====
684 684  
685 685  (((
686 -This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
693 +This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
687 687  )))
688 688  
689 689  * (((
... ... @@ -781,7 +781,7 @@
781 781  XX XX XX XX: AT+COMMAND or AT+DATACUT command
782 782  )))
783 783  * (((
784 -YY:  If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.
791 +YY:  If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.
785 785  )))
786 786  
787 787  (((
... ... @@ -1196,11 +1196,11 @@
1196 1196  == 3.7 Buttons ==
1197 1197  
1198 1198  
1199 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:400px" %)
1200 -|=(% style="width: 50px;" %)**Button**|=(% style="width: 350px;" %)**Feature**
1201 -|(% style="width:50px" %)**ACT**|(% style="width:350px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1202 -|(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485
1203 -|(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1206 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1207 +|=(% style="width: 50px;" %)**Button**|=(% style="width: 361px;" %)**Feature**
1208 +|(% style="width:50px" %)**ACT**|(% style="width:361px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1209 +|(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485
1210 +|(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1204 1204  
1205 1205  == 3.8 LEDs ==
1206 1206  
... ... @@ -1220,7 +1220,7 @@
1220 1220  == 5.1 Access AT Command ==
1221 1221  
1222 1222  (((
1223 -RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1230 +RS485-LN supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-LN to use AT command, as below.
1224 1224  )))
1225 1225  
1226 1226  [[image:1654162355560-817.png]]
... ... @@ -1227,7 +1227,7 @@
1227 1227  
1228 1228  
1229 1229  (((
1230 -In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1237 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-LN. The default password is 123456. Below is the output for reference:
1231 1231  )))
1232 1232  
1233 1233  [[image:1654162368066-342.png]]
... ... @@ -1376,9 +1376,9 @@
1376 1376  User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
1377 1377  
1378 1378  
1379 -== 6.3 How many RS485-Slave can RS485-BL connects? ==
1386 +== 6.3 How many RS485-Slave can RS485-LN connects? ==
1380 1380  
1381 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1388 +The RS485-LN can support max 32 RS485 devices. Each uplink command of RS485-LN can support max 16 different RS485 command. So RS485-LN can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1382 1382  
1383 1383  
1384 1384  == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved