Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -93,7 +93,6 @@ 93 93 * Packet engine up to 256 bytes with CRC 94 94 95 95 96 - 97 97 == 1.3 Features == 98 98 99 99 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -106,7 +106,6 @@ 106 106 * Support Interrupt uplink (Since hardware version v1.2) 107 107 108 108 109 - 110 110 == 1.4 Applications == 111 111 112 112 * Smart Buildings & Home Automation ... ... @@ -117,7 +117,6 @@ 117 117 * Smart Factory 118 118 119 119 120 - 121 121 == 1.5 Firmware Change log == 122 122 123 123 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -326,17 +326,11 @@ 326 326 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 327 327 |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 328 328 |AT+CFGDEV|(% style="width:110px" %)((( 329 -((( 330 330 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 331 -))) 332 332 333 -((( 334 334 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 335 -))) 336 336 337 -((( 338 338 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 339 -))) 340 340 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 341 341 342 342 === 3.3.3 Configure read commands for each sampling === ... ... @@ -1116,29 +1116,29 @@ 1116 1116 ))) 1117 1117 1118 1118 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1119 -|=(% style="width: 1 00px;" %)(((1120 -**Command example** 1121 -)))|=(% style="width: 400px;" %)(((1110 +|=(% style="width: 161px;" %)((( 1111 +**Command example:** 1112 +)))|=(% style="width: 337px;" %)((( 1122 1122 **Function** 1123 1123 ))) 1124 -|(% style="width:1 00px" %)(((1115 +|(% style="width:161px" %)((( 1125 1125 AT+RXMODE=1,10 1126 -)))|(% style="width: 400px" %)(((1117 +)))|(% style="width:337px" %)((( 1127 1127 Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1128 1128 ))) 1129 -|(% style="width:1 00px" %)(((1120 +|(% style="width:161px" %)((( 1130 1130 AT+RXMODE=2,500 1131 -)))|(% style="width: 400px" %)(((1122 +)))|(% style="width:337px" %)((( 1132 1132 Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1133 1133 ))) 1134 -|(% style="width:1 00px" %)(((1125 +|(% style="width:161px" %)((( 1135 1135 AT+RXMODE=0,0 1136 -)))|(% style="width: 400px" %)(((1127 +)))|(% style="width:337px" %)((( 1137 1137 Disable listening mode. This is the default settings. 1138 1138 ))) 1139 -|(% style="width:1 00px" %)(((1130 +|(% style="width:161px" %)((( 1140 1140 1141 -)))|(% style="width: 400px" %)(((1132 +)))|(% style="width:337px" %)((( 1142 1142 A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1143 1143 ))) 1144 1144 ... ... @@ -1187,10 +1187,8 @@ 1187 1187 ))) 1188 1188 1189 1189 ((( 1190 -((( 1191 1191 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1192 1192 ))) 1193 -))) 1194 1194 1195 1195 1196 1196 == 3.7 Buttons == ... ... @@ -1261,9 +1261,7 @@ 1261 1261 ))) 1262 1262 1263 1263 1264 -((( 1265 1265 If device already joined network: 1266 -))) 1267 1267 1268 1268 (% class="box infomessage" %) 1269 1269 ((( ... ... @@ -1302,12 +1302,10 @@ 1302 1302 1303 1303 (% style="color:red" %)**Note:** 1304 1304 1305 -((( 1306 1306 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1307 1307 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1308 1308 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1309 1309 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1310 -))) 1311 1311 1312 1312 [[image:1654162478620-421.png]] 1313 1313 ... ... @@ -1336,25 +1336,17 @@ 1336 1336 1337 1337 [[image:1654162535040-878.png]] 1338 1338 1339 -((( 1340 1340 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1341 -))) 1342 1342 1343 -((( 1344 1344 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1345 -))) 1346 1346 1347 -((( 1348 1348 **Step3: **Open flashloader; choose the correct COM port to update. 1349 -))) 1350 1350 1351 1351 ((( 1352 1352 ((( 1353 -((( 1354 1354 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 1355 1355 ))) 1356 1356 ))) 1357 -))) 1358 1358 1359 1359 1360 1360 [[image:image-20220602175818-12.png]]