<
From version < 59.3 >
edited by Xiaoling
on 2022/06/06 14:20
To version < 58.47 >
edited by Xiaoling
on 2022/06/06 13:44
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -92,8 +92,6 @@
92 92  * Automatic RF Sense and CAD with ultra-fast AFC.
93 93  * Packet engine up to 256 bytes with CRC
94 94  
95 -
96 -
97 97  == 1.3 Features ==
98 98  
99 99  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -105,8 +105,6 @@
105 105  * Support Modbus protocol
106 106  * Support Interrupt uplink (Since hardware version v1.2)
107 107  
108 -
109 -
110 110  == 1.4 Applications ==
111 111  
112 112  * Smart Buildings & Home Automation
... ... @@ -313,6 +313,7 @@
313 313  )))
314 314  )))
315 315  
312 +
316 316  === 3.3.2 Configure sensors ===
317 317  
318 318  (((
... ... @@ -324,19 +324,14 @@
324 324  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
325 325  |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
326 326  |AT+CFGDEV|(% style="width:110px" %)(((
327 -(((
328 328  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
329 -)))
330 330  
331 -(((
332 332  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
333 -)))
334 334  
335 -(((
336 336  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
337 -)))
338 338  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
339 339  
331 +
340 340  === 3.3.3 Configure read commands for each sampling ===
341 341  
342 342  (((
... ... @@ -1185,10 +1185,8 @@
1185 1185  )))
1186 1186  
1187 1187  (((
1188 -(((
1189 1189  (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
1190 1190  )))
1191 -)))
1192 1192  
1193 1193  
1194 1194  == 3.7 Buttons ==
... ... @@ -1200,6 +1200,7 @@
1200 1200  |(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485
1201 1201  |(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1202 1202  
1193 +
1203 1203  == 3.8 LEDs ==
1204 1204  
1205 1205  
... ... @@ -1259,9 +1259,7 @@
1259 1259  )))
1260 1260  
1261 1261  
1262 -(((
1263 1263  If device already joined network:
1264 -)))
1265 1265  
1266 1266  (% class="box infomessage" %)
1267 1267  (((
... ... @@ -1300,12 +1300,10 @@
1300 1300  
1301 1301  (% style="color:red" %)**Note:**
1302 1302  
1303 -(((
1304 1304  (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server.
1305 1305  2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1306 1306  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1307 1307  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1308 -)))
1309 1309  
1310 1310  [[image:1654162478620-421.png]]
1311 1311  
... ... @@ -1334,25 +1334,17 @@
1334 1334  
1335 1335  [[image:1654162535040-878.png]]
1336 1336  
1337 -(((
1338 1338  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1339 -)))
1340 1340  
1341 -(((
1342 1342  **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1343 -)))
1344 1344  
1345 -(((
1346 1346  **Step3: **Open flashloader; choose the correct COM port to update.
1347 -)))
1348 1348  
1349 1349  (((
1350 1350  (((
1351 -(((
1352 1352  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1353 1353  )))
1354 1354  )))
1355 -)))
1356 1356  
1357 1357  
1358 1358  [[image:image-20220602175818-12.png]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0