<
From version < 59.3 >
edited by Xiaoling
on 2022/06/06 14:20
To version < 58.30 >
edited by Xiaoling
on 2022/06/06 11:42
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,5 @@
1 1  (% style="text-align:center" %)
2 -[[image:1653266934636-343.png||height="385" width="385"]]
2 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653266934636-343.png?width=385&height=385&rev=1.1||alt="1653266934636-343.png" height="385" width="385"]]
3 3  
4 4  
5 5  
... ... @@ -10,7 +10,59 @@
10 10  
11 11  **Table of Contents:**
12 12  
13 -{{toc/}}
13 +* [[1.Introduction>>path:#H1.Introduction]]
14 +** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>path:#H1.1A0WhatisRS485-LNRS485toLoRaWANConverter]]
15 +** [[1.2 Specifications>>path:#H1.2A0Specifications]]
16 +** [[1.3 Features>>path:#H1.3Features]]
17 +** [[1.4 Applications>>path:#H1.4A0Applications]]
18 +** [[1.5 Firmware Change log>>path:#H1.5A0FirmwareChangelog]]
19 +** [[1.6 Hardware Change log>>path:#H1.6HardwareChangelog]]
20 +* [[2. Power ON Device>>path:#H2.PowerONDevice]]
21 +* [[3. Operation Mode>>path:#H3.A0OperationMode]]
22 +** [[3.1 How it works?>>path:#H3.1Howitworks3F]]
23 +** [[3.2 Example to join LoRaWAN network>>path:#H3.2ExampletojoinLoRaWANnetwork]]
24 +** [[3.3 Configure Commands to read data>>path:#H3.3ConfigureCommandstoreaddata]]
25 +*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>path:#H3.3.1onfigureUARTsettingsforRS485orTTLcommunication]]
26 +*** [[3.3.2 Configure sensors>>path:#H3.3.2Configuresensors]]
27 +*** [[3.3.3 Configure read commands for each sampling>>path:#H3.3.3Configurereadcommandsforeachsampling]]
28 +*** [[3.3.4 Compose the uplink payload>>path:#H3.3.4Composetheuplinkpayload]]
29 +*** [[3.3.5 Uplink on demand>>path:#H3.3.5Uplinkondemand]]
30 +*** [[3.3.6 Uplink on Interrupt>>path:#H3.3.6UplinkonInterrupt]]
31 +** [[3.4 Uplink Payload>>path:#H3.4UplinkPayload]]
32 +** [[3.5 Configure RS485-BL via AT or Downlink>>path:#H3.5ConfigureRS485-BLviaATorDownlink]]
33 +*** [[3.5.1 Common Commands>>path:#H3.5.1CommonCommands]]
34 +*** [[3.5.2 Sensor related commands>>path:#H3.5.2Sensorrelatedcommands]]
35 +*** [[3.5.3 Sensor related commands>>path:#H3.5.3A0Sensorrelatedcommands]]
36 +**** [[RS485 Debug Command>>path:#HRS485DebugCommand]]
37 +**** [[Set Payload version>>path:#HSetPayloadversion]]
38 +**** [[Set RS485 Sampling Commands>>path:#HSetRS485SamplingCommands]]
39 +**** [[Fast command to handle MODBUS device>>path:#HFastcommandtohandleMODBUSdevice]]
40 +**** [[RS485 command timeout>>path:#HRS485commandtimeout]]
41 +**** [[Uplink payload mode>>path:#HUplinkpayloadmode]]
42 +**** [[Manually trigger an Uplink>>path:#HManuallytriggeranUplink]]
43 +**** [[Clear RS485 Command>>path:#HClearRS485Command]]
44 +**** [[Set Serial Communication Parameters>>path:#HSetSerialCommunicationParameters]]
45 +** [[3.6 Listening mode for RS485 network>>path:#H3.6A0ListeningmodeforRS485network]]
46 +** [[3.7 Buttons>>path:#H3.7Buttons]]
47 +** [[3.8 LEDs>>path:#H3.8LEDs]]
48 +* [[4. Case Study>>path:#H4.CaseStudy]]
49 +* [[5. Use AT Command>>path:#H5.UseATCommand]]
50 +** [[5.1 Access AT Command>>path:#H5.1AccessATCommand]]
51 +** [[5.2 Common AT Command Sequence>>path:#H5.2CommonATCommandSequence]]
52 +*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>path:#H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829]]
53 +*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>path:#H5.5.2Single-channelABPmode28UsewithLG012FLG0229]]
54 +* [[6. FAQ>>path:#H6.FAQ]]
55 +** [[6.1 How to upgrade the image?>>path:#H6.1Howtoupgradetheimage3F]]
56 +** [[6.2 How to change the LoRa Frequency Bands/Region?>>path:#H6.2HowtochangetheLoRaFrequencyBands2FRegion3F]]
57 +** [[6.3 How many RS485-Slave can RS485-BL connects?>>path:#H6.3HowmanyRS485-SlavecanRS485-BLconnects3F]]
58 +** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>path:#H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F]]
59 +* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
60 +** [[7.1 Downlink doesn’t work, how to solve it?>>path:#H7.1Downlinkdoesn2019twork2Chowtosolveit3F]]
61 +** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>path:#H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F]]
62 +* [[8. Order Info>>path:#H8.OrderInfo]]
63 +* [[9.Packing Info>>path:#H9.PackingInfo]]
64 +* [[10. FCC Caution for RS485LN-US915>>path:#H10.FCCCautionforRS485LN-US915]]
65 +* [[11. Support>>path:#H11.Support]]
14 14  
15 15  
16 16  
... ... @@ -52,7 +52,7 @@
52 52  )))
53 53  )))
54 54  
55 -[[image:1653267211009-519.png||height="419" width="724"]]
107 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653267211009-519.png?width=724&height=419&rev=1.1||alt="1653267211009-519.png" height="419" width="724"]]
56 56  
57 57  
58 58  == 1.2 Specifications ==
... ... @@ -92,8 +92,6 @@
92 92  * Automatic RF Sense and CAD with ultra-fast AFC.
93 93  * Packet engine up to 256 bytes with CRC
94 94  
95 -
96 -
97 97  == 1.3 Features ==
98 98  
99 99  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -105,8 +105,6 @@
105 105  * Support Modbus protocol
106 106  * Support Interrupt uplink (Since hardware version v1.2)
107 107  
108 -
109 -
110 110  == 1.4 Applications ==
111 111  
112 112  * Smart Buildings & Home Automation
... ... @@ -149,7 +149,7 @@
149 149  Once there is power, the RS485-LN will be on.
150 150  )))
151 151  
152 -[[image:1653268091319-405.png]]
200 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268091319-405.png?rev=1.1||alt="1653268091319-405.png"]]
153 153  
154 154  
155 155  )))
... ... @@ -170,7 +170,7 @@
170 170  
171 171  Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
172 172  
173 -[[image:1653268155545-638.png||height="334" width="724"]]
221 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268155545-638.png?width=724&height=334&rev=1.1||alt="1653268155545-638.png" height="334" width="724"]]
174 174  
175 175  
176 176  (((
... ... @@ -182,10 +182,10 @@
182 182  485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively.
183 183  )))
184 184  
185 -[[image:1653268227651-549.png||height="592" width="720"]]
233 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268227651-549.png?width=720&height=592&rev=1.1||alt="1653268227651-549.png" height="592" width="720"]]
186 186  
187 187  (((
188 -The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:
236 +The LG308 is already set to connect to (% class="wikiinternallink" %)[[TTN V3 network >>url:https://www.thethingsnetwork.org/]](%%). So what we need to now is only configure the TTN V3:
189 189  )))
190 190  
191 191  (((
... ... @@ -197,7 +197,7 @@
197 197  )))
198 198  )))
199 199  
200 -[[image:1652953462722-299.png]]
248 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953462722-299.png?rev=1.1||alt="1652953462722-299.png"]]
201 201  
202 202  (((
203 203  (((
... ... @@ -209,21 +209,21 @@
209 209  )))
210 210  )))
211 211  
212 -[[image:image-20220519174512-1.png]]
260 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-1.png?rev=1.1||alt="image-20220519174512-1.png"]]
213 213  
214 -[[image:image-20220519174512-2.png||height="323" width="720"]]
262 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-2.png?width=720&height=323&rev=1.1||alt="image-20220519174512-2.png" height="323" width="720"]]
215 215  
216 -[[image:image-20220519174512-3.png||height="556" width="724"]]
264 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-3.png?width=724&height=556&rev=1.1||alt="image-20220519174512-3.png" height="556" width="724"]]
217 217  
218 -[[image:image-20220519174512-4.png]]
266 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-4.png?rev=1.1||alt="image-20220519174512-4.png"]]
219 219  
220 220  You can also choose to create the device manually.
221 221  
222 -[[image:1652953542269-423.png||height="710" width="723"]]
270 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953542269-423.png?width=723&height=710&rev=1.1||alt="1652953542269-423.png" height="710" width="723"]]
223 223  
224 224  Add APP KEY and DEV EUI
225 225  
226 -[[image:1652953553383-907.png||height="514" width="724"]]
274 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953553383-907.png?width=724&height=514&rev=1.1||alt="1652953553383-907.png" height="514" width="724"]]
227 227  
228 228  
229 229  (((
... ... @@ -230,7 +230,7 @@
230 230  **Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
231 231  )))
232 232  
233 -[[image:1652953568895-172.png||height="232" width="724"]]
281 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953568895-172.png?width=724&height=232&rev=1.1||alt="1652953568895-172.png" height="232" width="724"]]
234 234  
235 235  
236 236  == 3.3 Configure Commands to read data ==
... ... @@ -237,15 +237,11 @@
237 237  
238 238  (((
239 239  (((
240 -(((
241 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
288 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
242 242  )))
243 -)))
244 244  
245 245  (((
246 -(((
247 247  (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1
248 -)))
249 249  
250 250  
251 251  )))
... ... @@ -324,17 +324,11 @@
324 324  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
325 325  |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
326 326  |AT+CFGDEV|(% style="width:110px" %)(((
327 -(((
328 328  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
329 -)))
330 330  
331 -(((
332 332  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
333 -)))
334 334  
335 -(((
336 336  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
337 -)))
338 338  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
339 339  
340 340  === 3.3.3 Configure read commands for each sampling ===
... ... @@ -395,17 +395,17 @@
395 395  
396 396  * Grab bytes:
397 397  
398 -[[image:image-20220602153621-1.png]]
436 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-1.png?rev=1.1||alt="image-20220602153621-1.png"]]
399 399  
400 400  
401 401  * Grab a section.
402 402  
403 -[[image:image-20220602153621-2.png]]
441 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-2.png?rev=1.1||alt="image-20220602153621-2.png"]]
404 404  
405 405  
406 406  * Grab different sections.
407 407  
408 -[[image:image-20220602153621-3.png]]
446 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-3.png?rev=1.1||alt="image-20220602153621-3.png"]]
409 409  
410 410  
411 411  )))
... ... @@ -440,7 +440,7 @@
440 440  Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
441 441  )))
442 442  
443 -[[image:1653269759169-150.png||height="513" width="716"]]
481 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653269759169-150.png?width=716&height=513&rev=1.1||alt="1653269759169-150.png" height="513" width="716"]]
444 444  
445 445  
446 446  (% style="color:#037691" %)**Examples: AT+DATAUP=1**
... ... @@ -458,7 +458,7 @@
458 458  1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
459 459  1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes
460 460  
461 -[[image:image-20220602155039-4.png]]
499 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602155039-4.png?rev=1.1||alt="image-20220602155039-4.png"]]
462 462  
463 463  
464 464  So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA
... ... @@ -483,7 +483,7 @@
483 483  
484 484  Below are the uplink payloads:
485 485  
486 -[[image:1654157178836-407.png]]
524 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157178836-407.png?rev=1.1||alt="1654157178836-407.png"]]
487 487  
488 488  
489 489  === 3.3.5 Uplink on demand ===
... ... @@ -502,7 +502,7 @@
502 502  
503 503  RS485-LN support external Interrupt uplink since hardware v1.2 release.
504 504  
505 -[[image:1654157342174-798.png]]
543 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157342174-798.png?rev=1.1||alt="1654157342174-798.png"]]
506 506  
507 507  Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet.
508 508  
... ... @@ -510,7 +510,7 @@
510 510  == 3.4 Uplink Payload ==
511 511  
512 512  
513 -[[image:image-20220606110929-1.png]]
551 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220606110929-1.png?rev=1.1||alt="image-20220606110929-1.png"]]
514 514  
515 515  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
516 516  
... ... @@ -526,7 +526,7 @@
526 526  )))
527 527  
528 528  * (((
529 -(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
567 +(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
530 530  )))
531 531  
532 532  * (((
... ... @@ -540,7 +540,7 @@
540 540  
541 541  === 3.5.1 Common Commands ===
542 542  
543 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
581 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
544 544  
545 545  
546 546  === 3.5.2 Sensor related commands ===
... ... @@ -547,7 +547,7 @@
547 547  
548 548  Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server.
549 549  
550 -[[image:image-20220602163333-5.png||height="263" width="1160"]]
588 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602163333-5.png?width=1160&height=263&rev=1.1||alt="image-20220602163333-5.png" height="263" width="1160"]]
551 551  
552 552  The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable)
553 553  
... ... @@ -672,7 +672,7 @@
672 672  )))
673 673  
674 674  (((
675 - [[image:1654159460680-153.png]]
713 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654159460680-153.png?rev=1.1||alt="1654159460680-153.png"]]
676 676  )))
677 677  
678 678  
... ... @@ -717,7 +717,7 @@
717 717  )))
718 718  
719 719  (((
720 -These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
758 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#H3.3.3Configurereadcommandsforeachsampling]].
721 721  )))
722 722  
723 723  (((
... ... @@ -833,9 +833,9 @@
833 833  AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
834 834  )))
835 835  
836 -[[image:image-20220602165351-6.png]]
874 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-6.png?rev=1.1||alt="image-20220602165351-6.png"]]
837 837  
838 -[[image:image-20220602165351-7.png]]
876 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-7.png?rev=1.1||alt="image-20220602165351-7.png"]]
839 839  
840 840  
841 841  
... ... @@ -903,7 +903,7 @@
903 903  )))
904 904  
905 905  (((
906 -The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
944 +The use of this command please see: [[Compose Uplink payload>>path:#H3.3.4Composetheuplinkpayload]]
907 907  )))
908 908  
909 909  * (((
... ... @@ -954,7 +954,7 @@
954 954  )))
955 955  
956 956  (((
957 -No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same.
995 +No AT Command for this, user can press the [[ACT button>>path:#H3.7Buttons]] for 1 second for the same.
958 958  )))
959 959  
960 960  (((
... ... @@ -1002,7 +1002,7 @@
1002 1002  The uplink screen shot is:
1003 1003  )))
1004 1004  
1005 -[[image:1654160691922-496.png]]
1043 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654160691922-496.png?rev=1.1||alt="1654160691922-496.png"]]
1006 1006  
1007 1007  
1008 1008  * (((
... ... @@ -1103,7 +1103,7 @@
1103 1103  RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN.
1104 1104  )))
1105 1105  
1106 -[[image:image-20220602171200-8.png||height="567" width="1007"]]
1144 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-8.png?width=1007&height=567&rev=1.1||alt="image-20220602171200-8.png" height="567" width="1007"]]
1107 1107  
1108 1108  (((
1109 1109  To enable the listening mode, use can run the command AT+RXMODE.
... ... @@ -1114,29 +1114,29 @@
1114 1114  )))
1115 1115  
1116 1116  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
1117 -|=(% style="width: 100px;" %)(((
1118 -**Command example**
1119 -)))|=(% style="width: 400px;" %)(((
1155 +|=(% style="width: 161px;" %)(((
1156 +**Command example:**
1157 +)))|=(% style="width: 337px;" %)(((
1120 1120  **Function**
1121 1121  )))
1122 -|(% style="width:100px" %)(((
1160 +|(% style="width:161px" %)(((
1123 1123  AT+RXMODE=1,10
1124 -)))|(% style="width:400px" %)(((
1162 +)))|(% style="width:337px" %)(((
1125 1125  Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
1126 1126  )))
1127 -|(% style="width:100px" %)(((
1165 +|(% style="width:161px" %)(((
1128 1128  AT+RXMODE=2,500
1129 -)))|(% style="width:400px" %)(((
1167 +)))|(% style="width:337px" %)(((
1130 1130  Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
1131 1131  )))
1132 -|(% style="width:100px" %)(((
1170 +|(% style="width:161px" %)(((
1133 1133  AT+RXMODE=0,0
1134 -)))|(% style="width:400px" %)(((
1172 +)))|(% style="width:337px" %)(((
1135 1135  Disable listening mode. This is the default settings.
1136 1136  )))
1137 -|(% style="width:100px" %)(((
1175 +|(% style="width:161px" %)(((
1138 1138  
1139 -)))|(% style="width:400px" %)(((
1177 +)))|(% style="width:337px" %)(((
1140 1140  A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 | cc)
1141 1141  )))
1142 1142  
... ... @@ -1177,7 +1177,7 @@
1177 1177  )))
1178 1178  
1179 1179  (((
1180 -[[image:image-20220602171200-9.png]]
1218 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-9.png?rev=1.1||alt="image-20220602171200-9.png"]]
1181 1181  )))
1182 1182  
1183 1183  (((
... ... @@ -1185,32 +1185,31 @@
1185 1185  )))
1186 1186  
1187 1187  (((
1188 -(((
1189 1189  (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
1190 1190  )))
1191 -)))
1192 1192  
1193 1193  
1194 1194  == 3.7 Buttons ==
1195 1195  
1196 1196  
1197 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:400px" %)
1198 -|=(% style="width: 50px;" %)**Button**|=(% style="width: 350px;" %)**Feature**
1199 -|(% style="width:50px" %)**ACT**|(% style="width:350px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1200 -|(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485
1201 -|(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1233 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1234 +|=(% style="width: 30px;" %)**Button**|=(% style="width: 355px;" %)**Feature**
1235 +|=(% style="width: 30px;" %)**ACT**|(% style="width:355px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1236 +|=(% style="width: 30px;" %)**RST**|(% style="width:355px" %)Reboot RS485
1237 +|=(% style="width: 30px;" %)**PRO**|(% style="width:355px" %)Use for upload image, see [[How to Update Image>>path:#H6.1Howtoupgradetheimage3F]]
1202 1202  
1239 +
1203 1203  == 3.8 LEDs ==
1204 1204  
1242 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)
1243 +|=(% style="width: 30px;" %)**LEDs**|=(% style="width: 400px;" %)**Feature**
1244 +|(% style="width:30px" %)**PWR**|=(% style="width: 400px;" %)Always on if there is power
1245 +|(% style="width:30px" %)**SYS**|=(% style="width: 400px;" %)After device is powered on, the SYS will (% style="color:green" %)fast blink in GREEN (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)on GREEN for 5 seconds(%%). SYS will (% style="color:green" %)blink Blue(%%) on every upload and (% style="color:green" %)blink Green(%%) once receive a downlink message.
1205 1205  
1206 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1207 -|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature**
1208 -|**PWR**|Always on if there is power
1209 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1210 1210  
1211 1211  = 4. Case Study =
1212 1212  
1213 -User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1250 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>path:/xwiki/bin/view/Main/Application%20Note%20%3A%20Communicate%20with%20Different%20Sensors%20-----%20RS485-LN%20%20RS485-BL/]]
1214 1214  
1215 1215  
1216 1216  = 5. Use AT Command =
... ... @@ -1221,7 +1221,7 @@
1221 1221  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1222 1222  )))
1223 1223  
1224 -[[image:1654162355560-817.png]]
1261 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162355560-817.png?rev=1.1||alt="1654162355560-817.png"]]
1225 1225  
1226 1226  
1227 1227  (((
... ... @@ -1228,11 +1228,11 @@
1228 1228  In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1229 1229  )))
1230 1230  
1231 -[[image:1654162368066-342.png]]
1268 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162368066-342.png?rev=1.1||alt="1654162368066-342.png"]]
1232 1232  
1233 1233  
1234 1234  (((
1235 -More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1272 +More detail AT Command manual can be found at [[AT Command Manual>>url:https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1236 1236  )))
1237 1237  
1238 1238  
... ... @@ -1259,9 +1259,7 @@
1259 1259  )))
1260 1260  
1261 1261  
1262 -(((
1263 1263  If device already joined network:
1264 -)))
1265 1265  
1266 1266  (% class="box infomessage" %)
1267 1267  (((
... ... @@ -1300,14 +1300,12 @@
1300 1300  
1301 1301  (% style="color:red" %)**Note:**
1302 1302  
1303 -(((
1304 1304  (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server.
1305 1305  2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1306 1306  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1307 1307  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1308 -)))
1309 1309  
1310 -[[image:1654162478620-421.png]]
1343 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162478620-421.png?rev=1.1||alt="1654162478620-421.png"]]
1311 1311  
1312 1312  
1313 1313  = 6. FAQ =
... ... @@ -1314,69 +1314,49 @@
1314 1314  
1315 1315  == 6.1 How to upgrade the image? ==
1316 1316  
1317 -(((
1318 1318  The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to:
1319 -)))
1320 1320  
1321 -* (((
1322 -Support new features
1323 -)))
1324 -* (((
1325 -For bug fix
1326 -)))
1327 -* (((
1328 -Change LoRaWAN bands.
1329 -)))
1352 +* Support new features
1353 +* For bug fix
1354 +* Change LoRaWAN bands.
1330 1330  
1331 -(((
1332 1332  Below shows the hardware connection for how to upload an image to RS485-LN:
1333 -)))
1334 1334  
1335 -[[image:1654162535040-878.png]]
1358 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162535040-878.png?rev=1.1||alt="1654162535040-878.png"]]
1336 1336  
1337 -(((
1338 1338  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1339 -)))
1340 1340  
1341 -(((
1342 1342  **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1343 -)))
1344 1344  
1345 -(((
1346 1346  **Step3: **Open flashloader; choose the correct COM port to update.
1347 -)))
1348 1348  
1349 1349  (((
1350 -(((
1351 -(((
1352 1352  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1353 1353  )))
1354 -)))
1355 -)))
1356 1356  
1357 1357  
1358 -[[image:image-20220602175818-12.png]]
1371 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175818-12.png?rev=1.1||alt="image-20220602175818-12.png"]]
1359 1359  
1360 1360  
1361 -[[image:image-20220602175848-13.png]]
1374 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175848-13.png?rev=1.1||alt="image-20220602175848-13.png"]]
1362 1362  
1363 1363  
1364 -[[image:image-20220602175912-14.png]]
1377 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175912-14.png?rev=1.1||alt="image-20220602175912-14.png"]]
1365 1365  
1366 1366  
1367 1367  **Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1368 1368  
1369 -[[image:image-20220602175638-10.png]]
1382 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175638-10.png?rev=1.1||alt="image-20220602175638-10.png"]]
1370 1370  
1371 1371  
1372 1372  == 6.2 How to change the LoRa Frequency Bands/Region? ==
1373 1373  
1374 -User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
1387 +User can follow the introduction for [[how to upgrade image>>path:#H6.1Howtoupgradetheimage3F]]. When download the images, choose the required image file for download.
1375 1375  
1376 1376  
1377 1377  == 6.3 How many RS485-Slave can RS485-BL connects? ==
1378 1378  
1379 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1392 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#H3.3.3Configurereadcommandsforeachsampling]].
1380 1380  
1381 1381  
1382 1382  == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==
... ... @@ -1383,7 +1383,7 @@
1383 1383  
1384 1384  When user need to use with ChirpStack or TTI. Please set AT+RPL=4.
1385 1385  
1386 -Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]
1399 +Detail info check this link: [[Set Packet Receiving Response Level>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.23SetPacketReceivingResponseLevel]]
1387 1387  
1388 1388  
1389 1389  = 7. Trouble Shooting =
... ... @@ -1390,12 +1390,12 @@
1390 1390  
1391 1391  == 7.1 Downlink doesn’t work, how to solve it? ==
1392 1392  
1393 -Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]]
1406 +Please see this link for debug: [[LoRaWAN Communication Debug>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/]]
1394 1394  
1395 1395  
1396 1396  == 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? ==
1397 1397  
1398 -It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1411 +It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]]
1399 1399  
1400 1400  
1401 1401  = 8. Order Info =
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0