From version < 59.2 >
edited by Xiaoling
on 2022/06/06 14:20
To version < 58.48 >
edited by Xiaoling
on 2022/06/06 13:44
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -92,8 +92,6 @@
92 92  * Automatic RF Sense and CAD with ultra-fast AFC.
93 93  * Packet engine up to 256 bytes with CRC
94 94  
95 -
96 -
97 97  == 1.3 Features ==
98 98  
99 99  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -311,6 +311,7 @@
311 311  )))
312 312  )))
313 313  
312 +
314 314  === 3.3.2 Configure sensors ===
315 315  
316 316  (((
... ... @@ -322,19 +322,14 @@
322 322  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
323 323  |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
324 324  |AT+CFGDEV|(% style="width:110px" %)(((
325 -(((
326 326  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
327 -)))
328 328  
329 -(((
330 330  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
331 -)))
332 332  
333 -(((
334 334  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
335 -)))
336 336  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
337 337  
331 +
338 338  === 3.3.3 Configure read commands for each sampling ===
339 339  
340 340  (((
... ... @@ -1183,10 +1183,8 @@
1183 1183  )))
1184 1184  
1185 1185  (((
1186 -(((
1187 1187  (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
1188 1188  )))
1189 -)))
1190 1190  
1191 1191  
1192 1192  == 3.7 Buttons ==
... ... @@ -1198,6 +1198,7 @@
1198 1198  |(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485
1199 1199  |(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1200 1200  
1193 +
1201 1201  == 3.8 LEDs ==
1202 1202  
1203 1203  
... ... @@ -1206,6 +1206,7 @@
1206 1206  |**PWR**|Always on if there is power
1207 1207  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1208 1208  
1202 +
1209 1209  = 4. Case Study =
1210 1210  
1211 1211  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1257,9 +1257,7 @@
1257 1257  )))
1258 1258  
1259 1259  
1260 -(((
1261 1261  If device already joined network:
1262 -)))
1263 1263  
1264 1264  (% class="box infomessage" %)
1265 1265  (((
... ... @@ -1298,12 +1298,10 @@
1298 1298  
1299 1299  (% style="color:red" %)**Note:**
1300 1300  
1301 -(((
1302 1302  (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server.
1303 1303  2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1304 1304  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1305 1305  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1306 -)))
1307 1307  
1308 1308  [[image:1654162478620-421.png]]
1309 1309  
... ... @@ -1332,25 +1332,17 @@
1332 1332  
1333 1333  [[image:1654162535040-878.png]]
1334 1334  
1335 -(((
1336 1336  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1337 -)))
1338 1338  
1339 -(((
1340 1340  **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1341 -)))
1342 1342  
1343 -(((
1344 1344  **Step3: **Open flashloader; choose the correct COM port to update.
1345 -)))
1346 1346  
1347 1347  (((
1348 1348  (((
1349 -(((
1350 1350  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1351 1351  )))
1352 1352  )))
1353 -)))
1354 1354  
1355 1355  
1356 1356  [[image:image-20220602175818-12.png]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0