Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -92,8 +92,6 @@ 92 92 * Automatic RF Sense and CAD with ultra-fast AFC. 93 93 * Packet engine up to 256 bytes with CRC 94 94 95 - 96 - 97 97 == 1.3 Features == 98 98 99 99 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -105,6 +105,7 @@ 105 105 * Support Modbus protocol 106 106 * Support Interrupt uplink (Since hardware version v1.2) 107 107 106 + 108 108 == 1.4 Applications == 109 109 110 110 * Smart Buildings & Home Automation ... ... @@ -114,6 +114,7 @@ 114 114 * Smart Cities 115 115 * Smart Factory 116 116 116 + 117 117 == 1.5 Firmware Change log == 118 118 119 119 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -235,15 +235,11 @@ 235 235 236 236 ((( 237 237 ((( 238 -((( 239 239 There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 240 240 ))) 241 -))) 242 242 243 243 ((( 244 -((( 245 245 (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 246 -))) 247 247 248 248 249 249 ))) ... ... @@ -311,6 +311,8 @@ 311 311 ))) 312 312 ))) 313 313 310 + 311 + 314 314 === 3.3.2 Configure sensors === 315 315 316 316 ((( ... ... @@ -322,19 +322,15 @@ 322 322 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 323 323 |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 324 324 |AT+CFGDEV|(% style="width:110px" %)((( 325 -((( 326 326 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 327 -))) 328 328 329 -((( 330 330 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 331 -))) 332 332 333 -((( 334 334 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 335 -))) 336 336 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 337 337 330 + 331 + 338 338 === 3.3.3 Configure read commands for each sampling === 339 339 340 340 ((( ... ... @@ -1112,29 +1112,29 @@ 1112 1112 ))) 1113 1113 1114 1114 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1115 -|=(% style="width: 1 00px;" %)(((1116 -**Command example** 1117 -)))|=(% style="width: 400px;" %)(((1109 +|=(% style="width: 161px;" %)((( 1110 +**Command example:** 1111 +)))|=(% style="width: 337px;" %)((( 1118 1118 **Function** 1119 1119 ))) 1120 -|(% style="width:1 00px" %)(((1114 +|(% style="width:161px" %)((( 1121 1121 AT+RXMODE=1,10 1122 -)))|(% style="width: 400px" %)(((1116 +)))|(% style="width:337px" %)((( 1123 1123 Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1124 1124 ))) 1125 -|(% style="width:1 00px" %)(((1119 +|(% style="width:161px" %)((( 1126 1126 AT+RXMODE=2,500 1127 -)))|(% style="width: 400px" %)(((1121 +)))|(% style="width:337px" %)((( 1128 1128 Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1129 1129 ))) 1130 -|(% style="width:1 00px" %)(((1124 +|(% style="width:161px" %)((( 1131 1131 AT+RXMODE=0,0 1132 -)))|(% style="width: 400px" %)(((1126 +)))|(% style="width:337px" %)((( 1133 1133 Disable listening mode. This is the default settings. 1134 1134 ))) 1135 -|(% style="width:1 00px" %)(((1129 +|(% style="width:161px" %)((( 1136 1136 1137 -)))|(% style="width: 400px" %)(((1131 +)))|(% style="width:337px" %)((( 1138 1138 A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1139 1139 ))) 1140 1140 ... ... @@ -1183,29 +1183,30 @@ 1183 1183 ))) 1184 1184 1185 1185 ((( 1186 -((( 1187 1187 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1188 1188 ))) 1189 -))) 1190 1190 1191 1191 1192 1192 == 3.7 Buttons == 1193 1193 1194 1194 1195 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:400px" %)1196 -|= (% style="width: 50px;" %)**Button**|=(% style="width:350px;" %)**Feature**1197 -| (% style="width:50px" %)**ACT**|(% style="width:350px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**1198 -| (% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS4851199 -| (% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]1187 +(% border="1" style="background-color:#f7faff; width:500px" %) 1188 +|=**Button**|=(% style="width: 1420px;" %)**Feature** 1189 +|**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 1190 +|**RST**|(% style="width:1420px" %)Reboot RS485 1191 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1200 1200 1201 -== 3.8 LEDs == 1202 1202 1203 1203 1204 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1205 -|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature** 1195 +== 3.8 LEDs == 1196 + 1197 +(% border="1" style="background-color:#f7faff; width:500px" %) 1198 +|=**LEDs**|=**Feature** 1206 1206 |**PWR**|Always on if there is power 1207 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink 1200 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1208 1208 1202 + 1203 + 1209 1209 = 4. Case Study = 1210 1210 1211 1211 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -1215,26 +1215,19 @@ 1215 1215 1216 1216 == 5.1 Access AT Command == 1217 1217 1218 -((( 1219 1219 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1220 -))) 1221 1221 1222 1222 [[image:1654162355560-817.png]] 1223 1223 1224 1224 1225 -((( 1226 1226 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1227 -))) 1228 1228 1229 1229 [[image:1654162368066-342.png]] 1230 1230 1231 1231 1232 -((( 1233 1233 More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1234 -))) 1235 1235 1236 1236 1237 - 1238 1238 == 5.2 Common AT Command Sequence == 1239 1239 1240 1240 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === ... ... @@ -1257,9 +1257,7 @@ 1257 1257 ))) 1258 1258 1259 1259 1260 -((( 1261 1261 If device already joined network: 1262 -))) 1263 1263 1264 1264 (% class="box infomessage" %) 1265 1265 ((( ... ... @@ -1298,12 +1298,10 @@ 1298 1298 1299 1299 (% style="color:red" %)**Note:** 1300 1300 1301 -((( 1302 1302 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1303 1303 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1304 1304 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1305 1305 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1306 -))) 1307 1307 1308 1308 [[image:1654162478620-421.png]] 1309 1309 ... ... @@ -1312,45 +1312,25 @@ 1312 1312 1313 1313 == 6.1 How to upgrade the image? == 1314 1314 1315 -((( 1316 1316 The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to: 1317 -))) 1318 1318 1319 -* ((( 1320 -Support new features 1321 -))) 1322 -* ((( 1323 -For bug fix 1324 -))) 1325 -* ((( 1326 -Change LoRaWAN bands. 1327 -))) 1301 +* Support new features 1302 +* For bug fix 1303 +* Change LoRaWAN bands. 1328 1328 1329 -((( 1330 1330 Below shows the hardware connection for how to upload an image to RS485-LN: 1331 -))) 1332 1332 1333 1333 [[image:1654162535040-878.png]] 1334 1334 1335 -((( 1336 1336 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1337 -))) 1338 1338 1339 -((( 1340 1340 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1341 -))) 1342 1342 1343 -((( 1344 1344 **Step3: **Open flashloader; choose the correct COM port to update. 1345 -))) 1346 1346 1347 1347 ((( 1348 -((( 1349 -((( 1350 1350 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 1351 1351 ))) 1352 -))) 1353 -))) 1354 1354 1355 1355 1356 1356 [[image:image-20220602175818-12.png]] ... ... @@ -1413,6 +1413,7 @@ 1413 1413 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1414 1414 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1415 1415 1380 + 1416 1416 = 9.Packing Info = 1417 1417 1418 1418 ... ... @@ -1429,6 +1429,7 @@ 1429 1429 * Package Size / pcs : 14.5 x 8 x 5 cm 1430 1430 * Weight / pcs : 170g 1431 1431 1397 + 1432 1432 = 10. FCC Caution for RS485LN-US915 = 1433 1433 1434 1434 (((