<
From version < 59.11 >
edited by Xiaoling
on 2022/06/06 14:22
To version < 58.49 >
edited by Xiaoling
on 2022/06/06 13:45
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -92,8 +92,6 @@
92 92  * Automatic RF Sense and CAD with ultra-fast AFC.
93 93  * Packet engine up to 256 bytes with CRC
94 94  
95 -
96 -
97 97  == 1.3 Features ==
98 98  
99 99  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -105,8 +105,6 @@
105 105  * Support Modbus protocol
106 106  * Support Interrupt uplink (Since hardware version v1.2)
107 107  
108 -
109 -
110 110  == 1.4 Applications ==
111 111  
112 112  * Smart Buildings & Home Automation
... ... @@ -116,8 +116,6 @@
116 116  * Smart Cities
117 117  * Smart Factory
118 118  
119 -
120 -
121 121  == 1.5 Firmware Change log ==
122 122  
123 123  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -316,7 +316,6 @@
316 316  )))
317 317  
318 318  
319 -
320 320  === 3.3.2 Configure sensors ===
321 321  
322 322  (((
... ... @@ -328,21 +328,14 @@
328 328  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
329 329  |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
330 330  |AT+CFGDEV|(% style="width:110px" %)(((
331 -(((
332 332  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
333 -)))
334 334  
335 -(((
336 336  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
337 -)))
338 338  
339 -(((
340 340  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
341 -)))
342 342  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
343 343  
344 344  
345 -
346 346  === 3.3.3 Configure read commands for each sampling ===
347 347  
348 348  (((
... ... @@ -1207,7 +1207,6 @@
1207 1207  |(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1208 1208  
1209 1209  
1210 -
1211 1211  == 3.8 LEDs ==
1212 1212  
1213 1213  
... ... @@ -1216,6 +1216,7 @@
1216 1216  |**PWR**|Always on if there is power
1217 1217  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1218 1218  
1204 +
1219 1219  = 4. Case Study =
1220 1220  
1221 1221  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1267,9 +1267,7 @@
1267 1267  )))
1268 1268  
1269 1269  
1270 -(((
1271 1271  If device already joined network:
1272 -)))
1273 1273  
1274 1274  (% class="box infomessage" %)
1275 1275  (((
... ... @@ -1308,12 +1308,10 @@
1308 1308  
1309 1309  (% style="color:red" %)**Note:**
1310 1310  
1311 -(((
1312 1312  (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server.
1313 1313  2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1314 1314  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1315 1315  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1316 -)))
1317 1317  
1318 1318  [[image:1654162478620-421.png]]
1319 1319  
... ... @@ -1342,25 +1342,17 @@
1342 1342  
1343 1343  [[image:1654162535040-878.png]]
1344 1344  
1345 -(((
1346 1346  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1347 -)))
1348 1348  
1349 -(((
1350 1350  **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1351 -)))
1352 1352  
1353 -(((
1354 1354  **Step3: **Open flashloader; choose the correct COM port to update.
1355 -)))
1356 1356  
1357 1357  (((
1358 1358  (((
1359 -(((
1360 1360  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1361 1361  )))
1362 1362  )))
1363 -)))
1364 1364  
1365 1365  
1366 1366  [[image:image-20220602175818-12.png]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0