From version < 59.1 >
edited by Xiaoling
on 2022/06/06 14:19
To version < 58.43 >
edited by Xiaoling
on 2022/06/06 13:35
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -92,6 +92,7 @@
92 92  * Automatic RF Sense and CAD with ultra-fast AFC.
93 93  * Packet engine up to 256 bytes with CRC
94 94  
95 +
95 95  == 1.3 Features ==
96 96  
97 97  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -103,6 +103,7 @@
103 103  * Support Modbus protocol
104 104  * Support Interrupt uplink (Since hardware version v1.2)
105 105  
107 +
106 106  == 1.4 Applications ==
107 107  
108 108  * Smart Buildings & Home Automation
... ... @@ -112,6 +112,7 @@
112 112  * Smart Cities
113 113  * Smart Factory
114 114  
117 +
115 115  == 1.5 Firmware Change log ==
116 116  
117 117  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -310,6 +310,7 @@
310 310  )))
311 311  
312 312  
316 +
313 313  === 3.3.2 Configure sensors ===
314 314  
315 315  (((
... ... @@ -321,20 +321,15 @@
321 321  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
322 322  |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
323 323  |AT+CFGDEV|(% style="width:110px" %)(((
324 -(((
325 325  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
326 -)))
327 327  
328 -(((
329 329  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
330 -)))
331 331  
332 -(((
333 333  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
334 -)))
335 335  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
336 336  
337 337  
336 +
338 338  === 3.3.3 Configure read commands for each sampling ===
339 339  
340 340  (((
... ... @@ -1112,29 +1112,29 @@
1112 1112  )))
1113 1113  
1114 1114  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
1115 -|=(% style="width: 100px;" %)(((
1116 -**Command example**
1117 -)))|=(% style="width: 400px;" %)(((
1114 +|=(% style="width: 161px;" %)(((
1115 +**Command example:**
1116 +)))|=(% style="width: 337px;" %)(((
1118 1118  **Function**
1119 1119  )))
1120 -|(% style="width:100px" %)(((
1119 +|(% style="width:161px" %)(((
1121 1121  AT+RXMODE=1,10
1122 -)))|(% style="width:400px" %)(((
1121 +)))|(% style="width:337px" %)(((
1123 1123  Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
1124 1124  )))
1125 -|(% style="width:100px" %)(((
1124 +|(% style="width:161px" %)(((
1126 1126  AT+RXMODE=2,500
1127 -)))|(% style="width:400px" %)(((
1126 +)))|(% style="width:337px" %)(((
1128 1128  Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
1129 1129  )))
1130 -|(% style="width:100px" %)(((
1129 +|(% style="width:161px" %)(((
1131 1131  AT+RXMODE=0,0
1132 -)))|(% style="width:400px" %)(((
1131 +)))|(% style="width:337px" %)(((
1133 1133  Disable listening mode. This is the default settings.
1134 1134  )))
1135 -|(% style="width:100px" %)(((
1134 +|(% style="width:161px" %)(((
1136 1136  
1137 -)))|(% style="width:400px" %)(((
1136 +)))|(% style="width:337px" %)(((
1138 1138  A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 | cc)
1139 1139  )))
1140 1140  
... ... @@ -1183,10 +1183,8 @@
1183 1183  )))
1184 1184  
1185 1185  (((
1186 -(((
1187 1187  (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
1188 1188  )))
1189 -)))
1190 1190  
1191 1191  
1192 1192  == 3.7 Buttons ==
... ... @@ -1198,7 +1198,6 @@
1198 1198  |(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485
1199 1199  |(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1200 1200  
1201 -
1202 1202  == 3.8 LEDs ==
1203 1203  
1204 1204  
... ... @@ -1207,7 +1207,6 @@
1207 1207  |**PWR**|Always on if there is power
1208 1208  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1209 1209  
1210 -
1211 1211  = 4. Case Study =
1212 1212  
1213 1213  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1259,9 +1259,7 @@
1259 1259  )))
1260 1260  
1261 1261  
1262 -(((
1263 1263  If device already joined network:
1264 -)))
1265 1265  
1266 1266  (% class="box infomessage" %)
1267 1267  (((
... ... @@ -1300,12 +1300,10 @@
1300 1300  
1301 1301  (% style="color:red" %)**Note:**
1302 1302  
1303 -(((
1304 1304  (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server.
1305 1305  2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1306 1306  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1307 1307  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1308 -)))
1309 1309  
1310 1310  [[image:1654162478620-421.png]]
1311 1311  
... ... @@ -1334,25 +1334,17 @@
1334 1334  
1335 1335  [[image:1654162535040-878.png]]
1336 1336  
1337 -(((
1338 1338  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1339 -)))
1340 1340  
1341 -(((
1342 1342  **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1343 -)))
1344 1344  
1345 -(((
1346 1346  **Step3: **Open flashloader; choose the correct COM port to update.
1347 -)))
1348 1348  
1349 1349  (((
1350 1350  (((
1351 -(((
1352 1352  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1353 1353  )))
1354 1354  )))
1355 -)))
1356 1356  
1357 1357  
1358 1358  [[image:image-20220602175818-12.png]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0