... ... @@ -795,18 +795,35 @@
795 795  
796 796  ==== **Fast command to handle MODBUS device** ====
797 797  
798 +(((
798 798  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
800 +)))
799 799  
802 +(((
800 800  This command is valid since v1.3 firmware version
804 +)))
801 801  
806 +(((
802 802  AT+MBFUN can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore.
808 +)))
803 803  
810 +(((
811 +
812 +)))
804 804  
814 +(((
805 805  **Example:**
816 +)))
806 806  
807 -* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
808 -* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
809 -* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
818 +* (((
819 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
820 +)))
821 +* (((
822 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
823 +)))
824 +* (((
825 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
826 +)))
810 810  
811 811  [[image:image-20220602165351-6.png]]
812 812  
... ... @@ -816,31 +816,56 @@
816 816  
817 817  ==== **RS485 command timeout** ====
818 818  
836 +(((
819 819  Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
838 +)))
820 820  
840 +(((
821 821  Default value: 0, range:  0 ~~ 65 seconds
842 +)))
822 822  
823 -* **AT Command:**
844 +* (((
845 +**AT Command:**
846 +)))
824 824  
825 825  (% class="box infomessage" %)
826 826  (((
850 +(((
827 827  **AT+CMDDLaa=hex(bb cc)*1000**
828 828  )))
853 +)))
829 829  
855 +(((
830 830  **Example:**
857 +)))
831 831  
859 +(((
832 832  **AT+CMDDL1=1000** to send the open time to 1000ms
861 +)))
833 833  
863 +(((
864 +
865 +)))
834 834  
835 -* **Downlink Payload:**
867 +* (((
868 +**Downlink Payload:**
869 +)))
836 836  
871 +(((
837 837  **0x AA aa bb cc**
873 +)))
838 838  
875 +(((
839 839  Same as: AT+CMDDLaa=hex(bb cc)*1000
877 +)))
840 840  
879 +(((
841 841   **Example:**
881 +)))
842 842  
883 +(((
843 843   0xAA 01 00 01  ~-~-> Same as **AT+CMDDL1=1000 ms**
885 +)))
844 844  
845 845  
846 846  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved