... ... @@ -669,6 +669,7 @@
669 669  
670 670  
671 671  
672 +
672 672  ==== **Set Payload version** ====
673 673  
674 674  (((
... ... @@ -703,64 +703,126 @@
703 703  
704 704  ==== **Set RS485 Sampling Commands** ====
705 705  
707 +(((
706 706  AT+COMMANDx or AT+DATACUTx
709 +)))
707 707  
711 +(((
708 708  These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
713 +)))
709 709  
715 +(((
716 +
717 +)))
710 710  
711 -* **AT Command:**
719 +* (((
720 +**AT Command:**
721 +)))
712 712  
713 713  (% class="box infomessage" %)
714 714  (((
725 +(((
715 715  **AT+COMMANDx: Configure RS485 read command to sensor.**
716 716  )))
728 +)))
717 717  
718 718  (% class="box infomessage" %)
719 719  (((
732 +(((
720 720  **AT+DATACUTx: Configure how to handle return from RS485 devices.**
721 721  )))
735 +)))
722 722  
737 +(((
738 +
739 +)))
723 723  
724 -* **Downlink Payload:**
741 +* (((
742 +**Downlink Payload:**
743 +)))
725 725  
745 +(((
726 726  **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
747 +)))
727 727  
749 +(((
728 728  (% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
751 +)))
729 729  
753 +(((
730 730  Format: AF MM NN LL XX XX XX XX YY
755 +)))
731 731  
757 +(((
732 732  Where:
759 +)))
733 733  
734 -* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
735 -* NN:  0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
736 -* LL:  The length of AT+COMMAND or AT+DATACUT command
737 -* XX XX XX XX: AT+COMMAND or AT+DATACUT command
738 -* YY:  If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.
761 +* (((
762 +MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
763 +)))
764 +* (((
765 +NN:  0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
766 +)))
767 +* (((
768 +LL:  The length of AT+COMMAND or AT+DATACUT command
769 +)))
770 +* (((
771 +XX XX XX XX: AT+COMMAND or AT+DATACUT command
772 +)))
773 +* (((
774 +YY:  If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.
775 +)))
739 739  
777 +(((
740 740  **Example:**
779 +)))
741 741  
781 +(((
742 742  (% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1
783 +)))
743 743  
785 +(((
744 744  (% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10**
787 +)))
745 745  
789 +(((
746 746  (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10**
791 +)))
747 747  
748 748  
749 749  
795 +
750 750  ==== **Fast command to handle MODBUS device** ====
751 751  
798 +(((
752 752  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
800 +)))
753 753  
802 +(((
754 754  This command is valid since v1.3 firmware version
804 +)))
755 755  
806 +(((
756 756  AT+MBFUN can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore.
808 +)))
757 757  
810 +(((
811 +
812 +)))
758 758  
814 +(((
759 759  **Example:**
816 +)))
760 760  
761 -* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
762 -* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
763 -* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
818 +* (((
819 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
820 +)))
821 +* (((
822 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
823 +)))
824 +* (((
825 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
826 +)))
764 764  
765 765  [[image:image-20220602165351-6.png]]
766 766  
... ... @@ -770,31 +770,56 @@
770 770  
771 771  ==== **RS485 command timeout** ====
772 772  
836 +(((
773 773  Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
838 +)))
774 774  
840 +(((
775 775  Default value: 0, range:  0 ~~ 65 seconds
842 +)))
776 776  
777 -* **AT Command:**
844 +* (((
845 +**AT Command:**
846 +)))
778 778  
779 779  (% class="box infomessage" %)
780 780  (((
850 +(((
781 781  **AT+CMDDLaa=hex(bb cc)*1000**
782 782  )))
853 +)))
783 783  
855 +(((
784 784  **Example:**
857 +)))
785 785  
859 +(((
786 786  **AT+CMDDL1=1000** to send the open time to 1000ms
861 +)))
787 787  
863 +(((
864 +
865 +)))
788 788  
789 -* **Downlink Payload:**
867 +* (((
868 +**Downlink Payload:**
869 +)))
790 790  
871 +(((
791 791  **0x AA aa bb cc**
873 +)))
792 792  
875 +(((
793 793  Same as: AT+CMDDLaa=hex(bb cc)*1000
877 +)))
794 794  
879 +(((
795 795   **Example:**
881 +)))
796 796  
883 +(((
797 797   0xAA 01 00 01  ~-~-> Same as **AT+CMDDL1=1000 ms**
885 +)))
798 798  
799 799  
800 800  