... ... @@ -501,35 +501,33 @@
501 501  
502 502  == 3.4 Uplink Payload ==
503 503  
504 +(% border="1" style="background-color:#4bacc6; color:white; width:734px" %)
505 +|**Size(bytes)**|(% style="width:120px" %)**2**|(% style="width:116px" %)**1**|(% style="width:386px" %)**Length depends on the return from the commands**
506 +|Value|(% style="width:120px" %)(((
507 +Battery(mV)
504 504  
505 -[[image:image-20220606110929-1.png]]
509 +&
506 506  
511 +Interrupt _Flag
512 +)))|(% style="width:116px" %)(((
513 +PAYLOAD_VER
514 +
515 +
516 +)))|(% style="width:386px" %)If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server.
517 +
507 507  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
508 508  
509 509  
510 510  == 3.5 Configure RS485-BL via AT or Downlink ==
511 511  
512 -(((
513 513  User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands
514 -)))
515 515  
516 -(((
517 517  There are two kinds of Commands:
518 -)))
519 519  
520 -* (((
521 -(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
522 -)))
527 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
523 523  
524 -* (((
525 -(% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
526 -)))
529 +* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
527 527  
528 -(((
529 -
530 -)))
531 -
532 -
533 533  === 3.5.1 Common Commands ===
534 534  
535 535  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -548,159 +548,82 @@
548 548  
549 549  
550 550  
551 -
552 552  ==== **RS485 Debug Command** ====
553 553  
554 -(((
555 555  This command is used to configure the RS485 devices; they won’t be used during sampling.
556 -)))
557 557  
558 -* (((
559 -**AT Command**
560 -)))
553 +* **AT Command**
561 561  
562 562  (% class="box infomessage" %)
563 563  (((
564 -(((
565 565  **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
566 566  )))
567 -)))
568 568  
569 -(((
570 570  m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
571 -)))
572 572  
573 -* (((
574 -**Downlink Payload**
575 -)))
562 +* **Downlink Payload**
576 576  
577 -(((
578 578  Format: A8 MM NN XX XX XX XX YY
579 -)))
580 580  
581 -(((
582 582  Where:
583 -)))
584 584  
585 -* (((
586 -MM: 1: add CRC-16/MODBUS ; 0: no CRC
587 -)))
588 -* (((
589 -NN: The length of RS485 command
590 -)))
591 -* (((
592 -XX XX XX XX: RS485 command total NN bytes
593 -)))
594 -* (((
595 -(((
596 -YY: How many bytes will be uplink from the return of this RS485 command,
597 -)))
568 +* MM: 1: add CRC-16/MODBUS ; 0: no CRC
569 +* NN: The length of RS485 command
570 +* XX XX XX XX: RS485 command total NN bytes
571 +* YY: How many bytes will be uplink from the return of this RS485 command,
572 +** if YY=0, RS485-LN will execute the downlink command without uplink;
573 +** if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200
574 +** if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200.
598 598  
599 -* (((
600 -if YY=0, RS485-LN will execute the downlink command without uplink;
601 -)))
602 -* (((
603 -if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200
604 -)))
605 -* (((
606 -if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200.
607 -)))
608 -)))
609 -
610 -(((
611 611  **Example 1** ~-~-> Configure without ask for uplink (YY=0)
612 -)))
613 613  
614 -(((
615 615  To connect a Modbus Alarm with below commands.
616 -)))
617 617  
618 -* (((
619 -The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
620 -)))
580 +* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
621 621  
622 -* (((
623 -The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
624 -)))
582 +* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
625 625  
626 -(((
627 627  So if user want to use downlink command to control to RS485 Alarm, he can use:
628 -)))
629 629  
630 -(((
631 631  (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm
632 -)))
633 633  
634 -(((
635 635  (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm
636 -)))
637 637  
638 -(((
639 639  A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
640 -)))
641 641  
642 -(((
643 -
644 -)))
645 645  
646 -(((
647 647  **Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
648 -)))
649 649  
650 -(((
651 651  User in IoT server send a downlink command: (% style="color:#4f81bd" %)**A8 01 06 0A 08 00 04 00 01 YY**
652 -)))
653 653  
654 -(((
655 -
656 -)))
657 657  
658 -(((
659 659  RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:
660 -)))
661 661  
662 -(((
663 663   **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
664 -)))
665 665  
666 -(((
667 667   [[image:1654159460680-153.png]]
668 -)))
669 669  
670 670  
671 671  
672 672  ==== **Set Payload version** ====
673 673  
674 -(((
675 675  This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
676 -)))
677 677  
678 -* (((
679 -**AT Command:**
680 -)))
610 +* **AT Command:**
681 681  
682 682  (% class="box infomessage" %)
683 683  (((
684 -(((
685 685  **AT+PAYVER: Set PAYVER field = 1**
686 686  )))
687 -)))
688 688  
689 -* (((
690 -**Downlink Payload:**
691 -)))
617 +* **Downlink Payload:**
692 692  
693 -(((
694 694  **0xAE 01**  ~-~-> Set PAYVER field =  0x01
695 -)))
696 696  
697 -(((
698 698  **0xAE 0F**   ~-~-> Set PAYVER field =  0x0F
699 -)))
700 700  
701 701  
702 702  
703 -
704 704  ==== **Set RS485 Sampling Commands** ====
705 705  
706 706  AT+COMMANDx or AT+DATACUTx