Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% style="text-align:center" %) 2 -[[image:1653266934636-343.png||height="385" width="385"]] 2 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653266934636-343.png?width=385&height=385&rev=1.1||alt="1653266934636-343.png" height="385" width="385"]] 3 3 4 4 5 5 ... ... @@ -10,7 +10,59 @@ 10 10 11 11 **Table of Contents:** 12 12 13 -{{toc/}} 13 +* [[1.Introduction>>path:#H1.Introduction]] 14 +** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>path:#H1.1A0WhatisRS485-LNRS485toLoRaWANConverter]] 15 +** [[1.2 Specifications>>path:#H1.2A0Specifications]] 16 +** [[1.3 Features>>path:#H1.3Features]] 17 +** [[1.4 Applications>>path:#H1.4A0Applications]] 18 +** [[1.5 Firmware Change log>>path:#H1.5A0FirmwareChangelog]] 19 +** [[1.6 Hardware Change log>>path:#H1.6HardwareChangelog]] 20 +* [[2. Power ON Device>>path:#H2.PowerONDevice]] 21 +* [[3. Operation Mode>>path:#H3.A0OperationMode]] 22 +** [[3.1 How it works?>>path:#H3.1Howitworks3F]] 23 +** [[3.2 Example to join LoRaWAN network>>path:#H3.2ExampletojoinLoRaWANnetwork]] 24 +** [[3.3 Configure Commands to read data>>path:#H3.3ConfigureCommandstoreaddata]] 25 +*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>path:#H3.3.1onfigureUARTsettingsforRS485orTTLcommunication]] 26 +*** [[3.3.2 Configure sensors>>path:#H3.3.2Configuresensors]] 27 +*** [[3.3.3 Configure read commands for each sampling>>path:#H3.3.3Configurereadcommandsforeachsampling]] 28 +*** [[3.3.4 Compose the uplink payload>>path:#H3.3.4Composetheuplinkpayload]] 29 +*** [[3.3.5 Uplink on demand>>path:#H3.3.5Uplinkondemand]] 30 +*** [[3.3.6 Uplink on Interrupt>>path:#H3.3.6UplinkonInterrupt]] 31 +** [[3.4 Uplink Payload>>path:#H3.4UplinkPayload]] 32 +** [[3.5 Configure RS485-BL via AT or Downlink>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] 33 +*** [[3.5.1 Common Commands>>path:#H3.5.1CommonCommands]] 34 +*** [[3.5.2 Sensor related commands>>path:#H3.5.2Sensorrelatedcommands]] 35 +*** [[3.5.3 Sensor related commands>>path:#H3.5.3A0Sensorrelatedcommands]] 36 +**** [[RS485 Debug Command>>path:#HRS485DebugCommand]] 37 +**** [[Set Payload version>>path:#HSetPayloadversion]] 38 +**** [[Set RS485 Sampling Commands>>path:#HSetRS485SamplingCommands]] 39 +**** [[Fast command to handle MODBUS device>>path:#HFastcommandtohandleMODBUSdevice]] 40 +**** [[RS485 command timeout>>path:#HRS485commandtimeout]] 41 +**** [[Uplink payload mode>>path:#HUplinkpayloadmode]] 42 +**** [[Manually trigger an Uplink>>path:#HManuallytriggeranUplink]] 43 +**** [[Clear RS485 Command>>path:#HClearRS485Command]] 44 +**** [[Set Serial Communication Parameters>>path:#HSetSerialCommunicationParameters]] 45 +** [[3.6 Listening mode for RS485 network>>path:#H3.6A0ListeningmodeforRS485network]] 46 +** [[3.7 Buttons>>path:#H3.7Buttons]] 47 +** [[3.8 LEDs>>path:#H3.8LEDs]] 48 +* [[4. Case Study>>path:#H4.CaseStudy]] 49 +* [[5. Use AT Command>>path:#H5.UseATCommand]] 50 +** [[5.1 Access AT Command>>path:#H5.1AccessATCommand]] 51 +** [[5.2 Common AT Command Sequence>>path:#H5.2CommonATCommandSequence]] 52 +*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>path:#H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829]] 53 +*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>path:#H5.5.2Single-channelABPmode28UsewithLG012FLG0229]] 54 +* [[6. FAQ>>path:#H6.FAQ]] 55 +** [[6.1 How to upgrade the image?>>path:#H6.1Howtoupgradetheimage3F]] 56 +** [[6.2 How to change the LoRa Frequency Bands/Region?>>path:#H6.2HowtochangetheLoRaFrequencyBands2FRegion3F]] 57 +** [[6.3 How many RS485-Slave can RS485-BL connects?>>path:#H6.3HowmanyRS485-SlavecanRS485-BLconnects3F]] 58 +** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>path:#H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F]] 59 +* [[7. Trouble Shooting>>path:#H7.TroubleShooting]] 60 +** [[7.1 Downlink doesn’t work, how to solve it?>>path:#H7.1Downlinkdoesn2019twork2Chowtosolveit3F]] 61 +** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>path:#H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F]] 62 +* [[8. Order Info>>path:#H8.OrderInfo]] 63 +* [[9.Packing Info>>path:#H9.PackingInfo]] 64 +* [[10. FCC Caution for RS485LN-US915>>path:#H10.FCCCautionforRS485LN-US915]] 65 +* [[11. Support>>path:#H11.Support]] 14 14 15 15 16 16 ... ... @@ -52,7 +52,7 @@ 52 52 ))) 53 53 ))) 54 54 55 -[[image:1653267211009-519.png||height="419" width="724"]] 107 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653267211009-519.png?width=724&height=419&rev=1.1||alt="1653267211009-519.png" height="419" width="724"]] 56 56 57 57 58 58 == 1.2 Specifications == ... ... @@ -145,7 +145,7 @@ 145 145 Once there is power, the RS485-LN will be on. 146 146 ))) 147 147 148 -[[image:1653268091319-405.png]] 200 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268091319-405.png?rev=1.1||alt="1653268091319-405.png"]] 149 149 150 150 151 151 ))) ... ... @@ -166,7 +166,7 @@ 166 166 167 167 Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 168 168 169 -[[image:1653268155545-638.png||height="334" width="724"]] 221 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268155545-638.png?width=724&height=334&rev=1.1||alt="1653268155545-638.png" height="334" width="724"]] 170 170 171 171 172 172 ((( ... ... @@ -178,10 +178,10 @@ 178 178 485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively. 179 179 ))) 180 180 181 -[[image:1653268227651-549.png||height="592" width="720"]] 233 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268227651-549.png?width=720&height=592&rev=1.1||alt="1653268227651-549.png" height="592" width="720"]] 182 182 183 183 ((( 184 -The LG308 is already set to connect to [[TTN V3 network >> path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:236 +The LG308 is already set to connect to (% class="wikiinternallink" %)[[TTN V3 network >>url:https://www.thethingsnetwork.org/]](%%). So what we need to now is only configure the TTN V3: 185 185 ))) 186 186 187 187 ((( ... ... @@ -193,7 +193,7 @@ 193 193 ))) 194 194 ))) 195 195 196 -[[image:1652953462722-299.png]] 248 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953462722-299.png?rev=1.1||alt="1652953462722-299.png"]] 197 197 198 198 ((( 199 199 ((( ... ... @@ -205,21 +205,21 @@ 205 205 ))) 206 206 ))) 207 207 208 -[[image:image-20220519174512-1.png]] 260 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-1.png?rev=1.1||alt="image-20220519174512-1.png"]] 209 209 210 -[[image:image-20220519174512-2.png||height="323" width="720"]] 262 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-2.png?width=720&height=323&rev=1.1||alt="image-20220519174512-2.png" height="323" width="720"]] 211 211 212 -[[image:image-20220519174512-3.png||height="556" width="724"]] 264 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-3.png?width=724&height=556&rev=1.1||alt="image-20220519174512-3.png" height="556" width="724"]] 213 213 214 -[[image:image-20220519174512-4.png]] 266 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-4.png?rev=1.1||alt="image-20220519174512-4.png"]] 215 215 216 216 You can also choose to create the device manually. 217 217 218 -[[image:1652953542269-423.png||height="710" width="723"]] 270 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953542269-423.png?width=723&height=710&rev=1.1||alt="1652953542269-423.png" height="710" width="723"]] 219 219 220 220 Add APP KEY and DEV EUI 221 221 222 -[[image:1652953553383-907.png||height="514" width="724"]] 274 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953553383-907.png?width=724&height=514&rev=1.1||alt="1652953553383-907.png" height="514" width="724"]] 223 223 224 224 225 225 ((( ... ... @@ -226,7 +226,7 @@ 226 226 **Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 227 227 ))) 228 228 229 -[[image:1652953568895-172.png||height="232" width="724"]] 281 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953568895-172.png?width=724&height=232&rev=1.1||alt="1652953568895-172.png" height="232" width="724"]] 230 230 231 231 232 232 == 3.3 Configure Commands to read data == ... ... @@ -233,15 +233,11 @@ 233 233 234 234 ((( 235 235 ((( 236 -((( 237 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 288 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 238 238 ))) 239 -))) 240 240 241 241 ((( 242 -((( 243 243 (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 244 -))) 245 245 246 246 247 247 ))) ... ... @@ -309,7 +309,6 @@ 309 309 ))) 310 310 ))) 311 311 312 - 313 313 === 3.3.2 Configure sensors === 314 314 315 315 ((( ... ... @@ -321,20 +321,13 @@ 321 321 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 322 322 |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 323 323 |AT+CFGDEV|(% style="width:110px" %)((( 324 -((( 325 325 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 326 -))) 327 327 328 -((( 329 329 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 330 -))) 331 331 332 -((( 333 333 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 334 -))) 335 335 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 336 336 337 - 338 338 === 3.3.3 Configure read commands for each sampling === 339 339 340 340 ((( ... ... @@ -393,17 +393,17 @@ 393 393 394 394 * Grab bytes: 395 395 396 -[[image:image-20220602153621-1.png]] 436 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-1.png?rev=1.1||alt="image-20220602153621-1.png"]] 397 397 398 398 399 399 * Grab a section. 400 400 401 -[[image:image-20220602153621-2.png]] 441 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-2.png?rev=1.1||alt="image-20220602153621-2.png"]] 402 402 403 403 404 404 * Grab different sections. 405 405 406 -[[image:image-20220602153621-3.png]] 446 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-3.png?rev=1.1||alt="image-20220602153621-3.png"]] 407 407 408 408 409 409 ))) ... ... @@ -438,7 +438,7 @@ 438 438 Where PAYVER is defined by AT+PAYVER, below is an example screen shot. 439 439 ))) 440 440 441 -[[image:1653269759169-150.png||height="513" width="716"]] 481 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653269759169-150.png?width=716&height=513&rev=1.1||alt="1653269759169-150.png" height="513" width="716"]] 442 442 443 443 444 444 (% style="color:#037691" %)**Examples: AT+DATAUP=1** ... ... @@ -456,7 +456,7 @@ 456 456 1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) 457 457 1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes 458 458 459 -[[image:image-20220602155039-4.png]] 499 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602155039-4.png?rev=1.1||alt="image-20220602155039-4.png"]] 460 460 461 461 462 462 So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA ... ... @@ -481,7 +481,7 @@ 481 481 482 482 Below are the uplink payloads: 483 483 484 -[[image:1654157178836-407.png]] 524 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157178836-407.png?rev=1.1||alt="1654157178836-407.png"]] 485 485 486 486 487 487 === 3.3.5 Uplink on demand === ... ... @@ -500,7 +500,7 @@ 500 500 501 501 RS485-LN support external Interrupt uplink since hardware v1.2 release. 502 502 503 -[[image:1654157342174-798.png]] 543 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157342174-798.png?rev=1.1||alt="1654157342174-798.png"]] 504 504 505 505 Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet. 506 506 ... ... @@ -508,7 +508,7 @@ 508 508 == 3.4 Uplink Payload == 509 509 510 510 511 -[[image:image-20220606110929-1.png]] 551 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220606110929-1.png?rev=1.1||alt="image-20220606110929-1.png"]] 512 512 513 513 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 514 514 ... ... @@ -524,7 +524,7 @@ 524 524 ))) 525 525 526 526 * ((( 527 -(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>> doc:Main.End.WebHome]]567 +(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 528 528 ))) 529 529 530 530 * ((( ... ... @@ -538,7 +538,7 @@ 538 538 539 539 === 3.5.1 Common Commands === 540 540 541 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>> doc:Main.End.WebHome]]581 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 542 542 543 543 544 544 === 3.5.2 Sensor related commands === ... ... @@ -545,7 +545,7 @@ 545 545 546 546 Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server. 547 547 548 -[[image:image-20220602163333-5.png||height="263" width="1160"]] 588 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602163333-5.png?width=1160&height=263&rev=1.1||alt="image-20220602163333-5.png" height="263" width="1160"]] 549 549 550 550 The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable) 551 551 ... ... @@ -670,7 +670,7 @@ 670 670 ))) 671 671 672 672 ((( 673 - [[image:1654159460680-153.png]] 713 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654159460680-153.png?rev=1.1||alt="1654159460680-153.png"]] 674 674 ))) 675 675 676 676 ... ... @@ -715,7 +715,7 @@ 715 715 ))) 716 716 717 717 ((( 718 -These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>> ||anchor="H3.3.3Configurereadcommandsforeachsampling"]].758 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#H3.3.3Configurereadcommandsforeachsampling]]. 719 719 ))) 720 720 721 721 ((( ... ... @@ -831,9 +831,9 @@ 831 831 AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 832 832 ))) 833 833 834 -[[image:image-20220602165351-6.png]] 874 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-6.png?rev=1.1||alt="image-20220602165351-6.png"]] 835 835 836 -[[image:image-20220602165351-7.png]] 876 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-7.png?rev=1.1||alt="image-20220602165351-7.png"]] 837 837 838 838 839 839 ... ... @@ -901,7 +901,7 @@ 901 901 ))) 902 902 903 903 ((( 904 -The use of this command please see: [[Compose Uplink payload>> ||anchor="H3.3.4Composetheuplinkpayload"]]944 +The use of this command please see: [[Compose Uplink payload>>path:#H3.3.4Composetheuplinkpayload]] 905 905 ))) 906 906 907 907 * ((( ... ... @@ -952,7 +952,7 @@ 952 952 ))) 953 953 954 954 ((( 955 -No AT Command for this, user can press the [[ACT button>> ||anchor="H3.7Buttons"]] for 1 second for the same.995 +No AT Command for this, user can press the [[ACT button>>path:#H3.7Buttons]] for 1 second for the same. 956 956 ))) 957 957 958 958 ((( ... ... @@ -1000,7 +1000,7 @@ 1000 1000 The uplink screen shot is: 1001 1001 ))) 1002 1002 1003 -[[image:1654160691922-496.png]] 1043 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654160691922-496.png?rev=1.1||alt="1654160691922-496.png"]] 1004 1004 1005 1005 1006 1006 * ((( ... ... @@ -1101,7 +1101,7 @@ 1101 1101 RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN. 1102 1102 ))) 1103 1103 1104 -[[image:image-20220602171200-8.png||height="567" width="1007"]] 1144 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-8.png?width=1007&height=567&rev=1.1||alt="image-20220602171200-8.png" height="567" width="1007"]] 1105 1105 1106 1106 ((( 1107 1107 To enable the listening mode, use can run the command AT+RXMODE. ... ... @@ -1112,29 +1112,29 @@ 1112 1112 ))) 1113 1113 1114 1114 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1115 -|=(% style="width: 1 00px;" %)(((1116 -**Command example** 1117 -)))|=(% style="width: 400px;" %)(((1155 +|=(% style="width: 161px;" %)((( 1156 +**Command example:** 1157 +)))|=(% style="width: 337px;" %)((( 1118 1118 **Function** 1119 1119 ))) 1120 -|(% style="width:1 00px" %)(((1160 +|(% style="width:161px" %)((( 1121 1121 AT+RXMODE=1,10 1122 -)))|(% style="width: 400px" %)(((1162 +)))|(% style="width:337px" %)((( 1123 1123 Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1124 1124 ))) 1125 -|(% style="width:1 00px" %)(((1165 +|(% style="width:161px" %)((( 1126 1126 AT+RXMODE=2,500 1127 -)))|(% style="width: 400px" %)(((1167 +)))|(% style="width:337px" %)((( 1128 1128 Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1129 1129 ))) 1130 -|(% style="width:1 00px" %)(((1170 +|(% style="width:161px" %)((( 1131 1131 AT+RXMODE=0,0 1132 -)))|(% style="width: 400px" %)(((1172 +)))|(% style="width:337px" %)((( 1133 1133 Disable listening mode. This is the default settings. 1134 1134 ))) 1135 -|(% style="width:1 00px" %)(((1175 +|(% style="width:161px" %)((( 1136 1136 1137 -)))|(% style="width: 400px" %)(((1177 +)))|(% style="width:337px" %)((( 1138 1138 A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1139 1139 ))) 1140 1140 ... ... @@ -1175,7 +1175,7 @@ 1175 1175 ))) 1176 1176 1177 1177 ((( 1178 -[[image:image-20220602171200-9.png]] 1218 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-9.png?rev=1.1||alt="image-20220602171200-9.png"]] 1179 1179 ))) 1180 1180 1181 1181 ((( ... ... @@ -1183,34 +1183,31 @@ 1183 1183 ))) 1184 1184 1185 1185 ((( 1186 -((( 1187 1187 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1188 1188 ))) 1189 -))) 1190 1190 1191 1191 1192 1192 == 3.7 Buttons == 1193 1193 1194 1194 1195 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:40 0px" %)1196 -|=(% style="width: 50px;" %)**Button**|=(% style="width: 350px;" %)**Feature**1197 -|(% style="width: 50px" %)**ACT**|(% style="width:350px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**1198 -|(% style="width: 50px" %)**RST**|(% style="width:350px" %)Reboot RS4851199 -|(% style="width: 50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]1233 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1234 +|=(% style="width: 30px;" %)**Button**|=(% style="width: 355px;" %)**Feature** 1235 +|=(% style="width: 30px;" %)**ACT**|(% style="width:355px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 1236 +|=(% style="width: 30px;" %)**RST**|(% style="width:355px" %)Reboot RS485 1237 +|=(% style="width: 30px;" %)**PRO**|(% style="width:355px" %)Use for upload image, see [[How to Update Image>>path:#H6.1Howtoupgradetheimage3F]] 1200 1200 1201 1201 1202 1202 == 3.8 LEDs == 1203 1203 1242 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %) 1243 +|=(% style="width: 30px;" %)**LEDs**|=(% style="width: 400px;" %)**Feature** 1244 +|(% style="width:30px" %)**PWR**|=(% style="width: 400px;" %)Always on if there is power 1245 +|(% style="width:30px" %)**SYS**|=(% style="width: 400px;" %)After device is powered on, the SYS will (% style="color:green" %)fast blink in GREEN (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)on GREEN for 5 seconds(%%). SYS will (% style="color:green" %)blink Blue(%%) on every upload and (% style="color:green" %)blink Green(%%) once receive a downlink message. 1204 1204 1205 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1206 -|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature** 1207 -|**PWR**|Always on if there is power 1208 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1209 1209 1210 - 1211 1211 = 4. Case Study = 1212 1212 1213 -User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>> doc:Main.Application\:Communicate.WebHome]]1250 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>path:/xwiki/bin/view/Main/Application%20Note%20%3A%20Communicate%20with%20Different%20Sensors%20-----%20RS485-LN%20%20RS485-BL/]] 1214 1214 1215 1215 1216 1216 = 5. Use AT Command = ... ... @@ -1221,7 +1221,7 @@ 1221 1221 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1222 1222 ))) 1223 1223 1224 -[[image:1654162355560-817.png]] 1261 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162355560-817.png?rev=1.1||alt="1654162355560-817.png"]] 1225 1225 1226 1226 1227 1227 ((( ... ... @@ -1228,11 +1228,11 @@ 1228 1228 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1229 1229 ))) 1230 1230 1231 -[[image:1654162368066-342.png]] 1268 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162368066-342.png?rev=1.1||alt="1654162368066-342.png"]] 1232 1232 1233 1233 1234 1234 ((( 1235 -More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1272 +More detail AT Command manual can be found at [[AT Command Manual>>url:https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1236 1236 ))) 1237 1237 1238 1238 ... ... @@ -1259,9 +1259,7 @@ 1259 1259 ))) 1260 1260 1261 1261 1262 -((( 1263 1263 If device already joined network: 1264 -))) 1265 1265 1266 1266 (% class="box infomessage" %) 1267 1267 ((( ... ... @@ -1300,14 +1300,12 @@ 1300 1300 1301 1301 (% style="color:red" %)**Note:** 1302 1302 1303 -((( 1304 1304 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1305 1305 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1306 1306 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1307 1307 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1308 -))) 1309 1309 1310 -[[image:1654162478620-421.png]] 1343 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162478620-421.png?rev=1.1||alt="1654162478620-421.png"]] 1311 1311 1312 1312 1313 1313 = 6. FAQ = ... ... @@ -1314,69 +1314,49 @@ 1314 1314 1315 1315 == 6.1 How to upgrade the image? == 1316 1316 1317 -((( 1318 1318 The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to: 1319 -))) 1320 1320 1321 -* ((( 1322 -Support new features 1323 -))) 1324 -* ((( 1325 -For bug fix 1326 -))) 1327 -* ((( 1328 -Change LoRaWAN bands. 1329 -))) 1352 +* Support new features 1353 +* For bug fix 1354 +* Change LoRaWAN bands. 1330 1330 1331 -((( 1332 1332 Below shows the hardware connection for how to upload an image to RS485-LN: 1333 -))) 1334 1334 1335 -[[image:1654162535040-878.png]] 1358 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162535040-878.png?rev=1.1||alt="1654162535040-878.png"]] 1336 1336 1337 -((( 1338 1338 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1339 -))) 1340 1340 1341 -((( 1342 1342 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1343 -))) 1344 1344 1345 -((( 1346 1346 **Step3: **Open flashloader; choose the correct COM port to update. 1347 -))) 1348 1348 1349 1349 ((( 1350 -((( 1351 -((( 1352 1352 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 1353 1353 ))) 1354 -))) 1355 -))) 1356 1356 1357 1357 1358 -[[image:image-20220602175818-12.png]] 1371 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175818-12.png?rev=1.1||alt="image-20220602175818-12.png"]] 1359 1359 1360 1360 1361 -[[image:image-20220602175848-13.png]] 1374 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175848-13.png?rev=1.1||alt="image-20220602175848-13.png"]] 1362 1362 1363 1363 1364 -[[image:image-20220602175912-14.png]] 1377 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175912-14.png?rev=1.1||alt="image-20220602175912-14.png"]] 1365 1365 1366 1366 1367 1367 **Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1368 1368 1369 -[[image:image-20220602175638-10.png]] 1382 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175638-10.png?rev=1.1||alt="image-20220602175638-10.png"]] 1370 1370 1371 1371 1372 1372 == 6.2 How to change the LoRa Frequency Bands/Region? == 1373 1373 1374 -User can follow the introduction for [[how to upgrade image>> ||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.1387 +User can follow the introduction for [[how to upgrade image>>path:#H6.1Howtoupgradetheimage3F]]. When download the images, choose the required image file for download. 1375 1375 1376 1376 1377 1377 == 6.3 How many RS485-Slave can RS485-BL connects? == 1378 1378 1379 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>> ||anchor="H3.3.3Configurereadcommandsforeachsampling"]].1392 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#H3.3.3Configurereadcommandsforeachsampling]]. 1380 1380 1381 1381 1382 1382 == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? == ... ... @@ -1383,7 +1383,7 @@ 1383 1383 1384 1384 When user need to use with ChirpStack or TTI. Please set AT+RPL=4. 1385 1385 1386 -Detail info check this link: [[Set Packet Receiving Response Level>> doc:Main.End.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]1399 +Detail info check this link: [[Set Packet Receiving Response Level>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.23SetPacketReceivingResponseLevel]] 1387 1387 1388 1388 1389 1389 = 7. Trouble Shooting = ... ... @@ -1390,12 +1390,12 @@ 1390 1390 1391 1391 == 7.1 Downlink doesn’t work, how to solve it? == 1392 1392 1393 -Please see this link for debug: [[LoRaWAN Communication Debug>> doc:Main.LoRaWAN.WebHome]]1406 +Please see this link for debug: [[LoRaWAN Communication Debug>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/]] 1394 1394 1395 1395 1396 1396 == 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? == 1397 1397 1398 -It might about the channels mapping. Please see for detail: [[Notice of Frequency band>> doc:Main.LoRaWAN.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]1411 +It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]] 1399 1399 1400 1400 1401 1401 = 8. Order Info =