... ... @@ -1253,9 +1253,7 @@
1253 1253  )))
1254 1254  
1255 1255  
1256 -(((
1257 1257  If device already joined network:
1258 -)))
1259 1259  
1260 1260  (% class="box infomessage" %)
1261 1261  (((
... ... @@ -1294,12 +1294,10 @@
1294 1294  
1295 1295  (% style="color:red" %)**Note:**
1296 1296  
1297 -(((
1298 1298  (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server.
1299 1299  2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1300 1300  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1301 1301  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1302 -)))
1303 1303  
1304 1304  [[image:1654162478620-421.png]]
1305 1305  