Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -92,6 +92,8 @@ 92 92 * Automatic RF Sense and CAD with ultra-fast AFC. 93 93 * Packet engine up to 256 bytes with CRC 94 94 95 + 96 + 95 95 == 1.3 Features == 96 96 97 97 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -309,7 +309,6 @@ 309 309 ))) 310 310 ))) 311 311 312 - 313 313 === 3.3.2 Configure sensors === 314 314 315 315 ((( ... ... @@ -321,14 +321,19 @@ 321 321 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 322 322 |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 323 323 |AT+CFGDEV|(% style="width:110px" %)((( 325 +((( 324 324 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 327 +))) 325 325 329 +((( 326 326 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 331 +))) 327 327 333 +((( 328 328 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 335 +))) 329 329 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 330 330 331 - 332 332 === 3.3.3 Configure read commands for each sampling === 333 333 334 334 ((( ... ... @@ -1192,7 +1192,6 @@ 1192 1192 |(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485 1193 1193 |(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1194 1194 1195 - 1196 1196 == 3.8 LEDs == 1197 1197 1198 1198 ... ... @@ -1201,7 +1201,6 @@ 1201 1201 |**PWR**|Always on if there is power 1202 1202 |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1203 1203 1204 - 1205 1205 = 4. Case Study = 1206 1206 1207 1207 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -1253,7 +1253,9 @@ 1253 1253 ))) 1254 1254 1255 1255 1260 +((( 1256 1256 If device already joined network: 1262 +))) 1257 1257 1258 1258 (% class="box infomessage" %) 1259 1259 (((