Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -103,6 +103,7 @@ 103 103 * Support Modbus protocol 104 104 * Support Interrupt uplink (Since hardware version v1.2) 105 105 106 + 106 106 == 1.4 Applications == 107 107 108 108 * Smart Buildings & Home Automation ... ... @@ -112,6 +112,7 @@ 112 112 * Smart Cities 113 113 * Smart Factory 114 114 116 + 115 115 == 1.5 Firmware Change log == 116 116 117 117 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -233,15 +233,11 @@ 233 233 234 234 ((( 235 235 ((( 236 -((( 237 237 There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 238 238 ))) 239 -))) 240 240 241 241 ((( 242 -((( 243 243 (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 244 -))) 245 245 246 246 247 247 ))) ... ... @@ -310,6 +310,7 @@ 310 310 ))) 311 311 312 312 311 + 313 313 === 3.3.2 Configure sensors === 314 314 315 315 ((( ... ... @@ -329,6 +329,7 @@ 329 329 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 330 330 331 331 331 + 332 332 === 3.3.3 Configure read commands for each sampling === 333 333 334 334 ((( ... ... @@ -1106,29 +1106,29 @@ 1106 1106 ))) 1107 1107 1108 1108 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1109 -|=(% style="width: 1 00px;" %)(((1110 -**Command example** 1111 -)))|=(% style="width: 400px;" %)(((1109 +|=(% style="width: 161px;" %)((( 1110 +**Command example:** 1111 +)))|=(% style="width: 337px;" %)((( 1112 1112 **Function** 1113 1113 ))) 1114 -|(% style="width:1 00px" %)(((1114 +|(% style="width:161px" %)((( 1115 1115 AT+RXMODE=1,10 1116 -)))|(% style="width: 400px" %)(((1116 +)))|(% style="width:337px" %)((( 1117 1117 Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1118 1118 ))) 1119 -|(% style="width:1 00px" %)(((1119 +|(% style="width:161px" %)((( 1120 1120 AT+RXMODE=2,500 1121 -)))|(% style="width: 400px" %)(((1121 +)))|(% style="width:337px" %)((( 1122 1122 Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1123 1123 ))) 1124 -|(% style="width:1 00px" %)(((1124 +|(% style="width:161px" %)((( 1125 1125 AT+RXMODE=0,0 1126 -)))|(% style="width: 400px" %)(((1126 +)))|(% style="width:337px" %)((( 1127 1127 Disable listening mode. This is the default settings. 1128 1128 ))) 1129 -|(% style="width:1 00px" %)(((1129 +|(% style="width:161px" %)((( 1130 1130 1131 -)))|(% style="width: 400px" %)(((1131 +)))|(% style="width:337px" %)((( 1132 1132 A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1133 1133 ))) 1134 1134 ... ... @@ -1177,31 +1177,28 @@ 1177 1177 ))) 1178 1178 1179 1179 ((( 1180 -((( 1181 1181 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1182 1182 ))) 1183 -))) 1184 1184 1185 1185 1186 1186 == 3.7 Buttons == 1187 1187 1188 1188 1189 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:400px" %)1190 -|= (% style="width: 50px;" %)**Button**|=(% style="width:350px;" %)**Feature**1191 -| (% style="width:50px" %)**ACT**|(% style="width:350px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**1192 -| (% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS4851193 -| (% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]1187 +(% border="1" style="background-color:#f7faff; width:500px" %) 1188 +|=**Button**|=(% style="width: 1420px;" %)**Feature** 1189 +|**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 1190 +|**RST**|(% style="width:1420px" %)Reboot RS485 1191 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1194 1194 1195 1195 1194 + 1196 1196 == 3.8 LEDs == 1197 1197 1198 - 1199 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1200 -|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature** 1197 +(% border="1" style="background-color:#f7faff; width:500px" %) 1198 +|=**LEDs**|=**Feature** 1201 1201 |**PWR**|Always on if there is power 1202 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink 1200 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1203 1203 1204 - 1205 1205 = 4. Case Study = 1206 1206 1207 1207 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -1211,26 +1211,19 @@ 1211 1211 1212 1212 == 5.1 Access AT Command == 1213 1213 1214 -((( 1215 1215 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1216 -))) 1217 1217 1218 1218 [[image:1654162355560-817.png]] 1219 1219 1220 1220 1221 -((( 1222 1222 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1223 -))) 1224 1224 1225 1225 [[image:1654162368066-342.png]] 1226 1226 1227 1227 1228 -((( 1229 1229 More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1230 -))) 1231 1231 1232 1232 1233 - 1234 1234 == 5.2 Common AT Command Sequence == 1235 1235 1236 1236 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === ... ... @@ -1292,12 +1292,10 @@ 1292 1292 1293 1293 (% style="color:red" %)**Note:** 1294 1294 1295 -((( 1296 1296 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1297 1297 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1298 1298 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1299 1299 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1300 -))) 1301 1301 1302 1302 [[image:1654162478620-421.png]] 1303 1303 ... ... @@ -1306,45 +1306,25 @@ 1306 1306 1307 1307 == 6.1 How to upgrade the image? == 1308 1308 1309 -((( 1310 1310 The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to: 1311 -))) 1312 1312 1313 -* ((( 1314 -Support new features 1315 -))) 1316 -* ((( 1317 -For bug fix 1318 -))) 1319 -* ((( 1320 -Change LoRaWAN bands. 1321 -))) 1299 +* Support new features 1300 +* For bug fix 1301 +* Change LoRaWAN bands. 1322 1322 1323 -((( 1324 1324 Below shows the hardware connection for how to upload an image to RS485-LN: 1325 -))) 1326 1326 1327 1327 [[image:1654162535040-878.png]] 1328 1328 1329 -((( 1330 1330 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1331 -))) 1332 1332 1333 -((( 1334 1334 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1335 -))) 1336 1336 1337 -((( 1338 1338 **Step3: **Open flashloader; choose the correct COM port to update. 1339 -))) 1340 1340 1341 1341 ((( 1342 -((( 1343 -((( 1344 1344 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 1345 1345 ))) 1346 -))) 1347 -))) 1348 1348 1349 1349 1350 1350 [[image:image-20220602175818-12.png]] ... ... @@ -1407,6 +1407,7 @@ 1407 1407 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1408 1408 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1409 1409 1378 + 1410 1410 = 9.Packing Info = 1411 1411 1412 1412 ... ... @@ -1423,6 +1423,7 @@ 1423 1423 * Package Size / pcs : 14.5 x 8 x 5 cm 1424 1424 * Weight / pcs : 170g 1425 1425 1395 + 1426 1426 = 10. FCC Caution for RS485LN-US915 = 1427 1427 1428 1428 (((