Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -92,6 +92,7 @@ 92 92 * Automatic RF Sense and CAD with ultra-fast AFC. 93 93 * Packet engine up to 256 bytes with CRC 94 94 95 + 95 95 == 1.3 Features == 96 96 97 97 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -103,6 +103,7 @@ 103 103 * Support Modbus protocol 104 104 * Support Interrupt uplink (Since hardware version v1.2) 105 105 107 + 106 106 == 1.4 Applications == 107 107 108 108 * Smart Buildings & Home Automation ... ... @@ -112,6 +112,7 @@ 112 112 * Smart Cities 113 113 * Smart Factory 114 114 117 + 115 115 == 1.5 Firmware Change log == 116 116 117 117 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -310,6 +310,7 @@ 310 310 ))) 311 311 312 312 316 + 313 313 === 3.3.2 Configure sensors === 314 314 315 315 ((( ... ... @@ -329,6 +329,7 @@ 329 329 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 330 330 331 331 336 + 332 332 === 3.3.3 Configure read commands for each sampling === 333 333 334 334 ((( ... ... @@ -1106,29 +1106,29 @@ 1106 1106 ))) 1107 1107 1108 1108 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1109 -|=(% style="width: 1 00px;" %)(((1110 -**Command example** 1111 -)))|=(% style="width: 400px;" %)(((1114 +|=(% style="width: 161px;" %)((( 1115 +**Command example:** 1116 +)))|=(% style="width: 337px;" %)((( 1112 1112 **Function** 1113 1113 ))) 1114 -|(% style="width:1 00px" %)(((1119 +|(% style="width:161px" %)((( 1115 1115 AT+RXMODE=1,10 1116 -)))|(% style="width: 400px" %)(((1121 +)))|(% style="width:337px" %)((( 1117 1117 Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1118 1118 ))) 1119 -|(% style="width:1 00px" %)(((1124 +|(% style="width:161px" %)((( 1120 1120 AT+RXMODE=2,500 1121 -)))|(% style="width: 400px" %)(((1126 +)))|(% style="width:337px" %)((( 1122 1122 Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1123 1123 ))) 1124 -|(% style="width:1 00px" %)(((1129 +|(% style="width:161px" %)((( 1125 1125 AT+RXMODE=0,0 1126 -)))|(% style="width: 400px" %)(((1131 +)))|(% style="width:337px" %)((( 1127 1127 Disable listening mode. This is the default settings. 1128 1128 ))) 1129 -|(% style="width:1 00px" %)(((1134 +|(% style="width:161px" %)((( 1130 1130 1131 -)))|(% style="width: 400px" %)(((1136 +)))|(% style="width:337px" %)((( 1132 1132 A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1133 1133 ))) 1134 1134 ... ... @@ -1177,10 +1177,8 @@ 1177 1177 ))) 1178 1178 1179 1179 ((( 1180 -((( 1181 1181 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1182 1182 ))) 1183 -))) 1184 1184 1185 1185 1186 1186 == 3.7 Buttons == ... ... @@ -1192,7 +1192,6 @@ 1192 1192 |(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485 1193 1193 |(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1194 1194 1195 - 1196 1196 == 3.8 LEDs == 1197 1197 1198 1198 ... ... @@ -1201,7 +1201,6 @@ 1201 1201 |**PWR**|Always on if there is power 1202 1202 |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1203 1203 1204 - 1205 1205 = 4. Case Study = 1206 1206 1207 1207 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -1324,25 +1324,17 @@ 1324 1324 1325 1325 [[image:1654162535040-878.png]] 1326 1326 1327 -((( 1328 1328 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1329 -))) 1330 1330 1331 -((( 1332 1332 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1333 -))) 1334 1334 1335 -((( 1336 1336 **Step3: **Open flashloader; choose the correct COM port to update. 1337 -))) 1338 1338 1339 1339 ((( 1340 1340 ((( 1341 -((( 1342 1342 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program. 1343 1343 ))) 1344 1344 ))) 1345 -))) 1346 1346 1347 1347 1348 1348 [[image:image-20220602175818-12.png]]