<
From version < 58.50 >
edited by Xiaoling
on 2022/06/06 13:46
To version < 59.6 >
edited by Xiaoling
on 2022/06/06 14:21
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -92,6 +92,8 @@
92 92  * Automatic RF Sense and CAD with ultra-fast AFC.
93 93  * Packet engine up to 256 bytes with CRC
94 94  
95 +
96 +
95 95  == 1.3 Features ==
96 96  
97 97  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -103,6 +103,8 @@
103 103  * Support Modbus protocol
104 104  * Support Interrupt uplink (Since hardware version v1.2)
105 105  
108 +
109 +
106 106  == 1.4 Applications ==
107 107  
108 108  * Smart Buildings & Home Automation
... ... @@ -112,6 +112,8 @@
112 112  * Smart Cities
113 113  * Smart Factory
114 114  
119 +
120 +
115 115  == 1.5 Firmware Change log ==
116 116  
117 117  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -321,14 +321,19 @@
321 321  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
322 322  |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
323 323  |AT+CFGDEV|(% style="width:110px" %)(((
330 +(((
324 324  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
332 +)))
325 325  
334 +(((
326 326  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
336 +)))
327 327  
338 +(((
328 328  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
340 +)))
329 329  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
330 330  
331 -
332 332  === 3.3.3 Configure read commands for each sampling ===
333 333  
334 334  (((
... ... @@ -1192,7 +1192,6 @@
1192 1192  |(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485
1193 1193  |(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1194 1194  
1195 -
1196 1196  == 3.8 LEDs ==
1197 1197  
1198 1198  
... ... @@ -1201,7 +1201,6 @@
1201 1201  |**PWR**|Always on if there is power
1202 1202  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1203 1203  
1204 -
1205 1205  = 4. Case Study =
1206 1206  
1207 1207  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1253,7 +1253,9 @@
1253 1253  )))
1254 1254  
1255 1255  
1265 +(((
1256 1256  If device already joined network:
1267 +)))
1257 1257  
1258 1258  (% class="box infomessage" %)
1259 1259  (((
... ... @@ -1292,10 +1292,12 @@
1292 1292  
1293 1293  (% style="color:red" %)**Note:**
1294 1294  
1306 +(((
1295 1295  (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server.
1296 1296  2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1297 1297  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1298 1298  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1311 +)))
1299 1299  
1300 1300  [[image:1654162478620-421.png]]
1301 1301  
... ... @@ -1324,17 +1324,25 @@
1324 1324  
1325 1325  [[image:1654162535040-878.png]]
1326 1326  
1340 +(((
1327 1327  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1342 +)))
1328 1328  
1344 +(((
1329 1329  **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1346 +)))
1330 1330  
1348 +(((
1331 1331  **Step3: **Open flashloader; choose the correct COM port to update.
1350 +)))
1332 1332  
1333 1333  (((
1334 1334  (((
1354 +(((
1335 1335  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1336 1336  )))
1337 1337  )))
1358 +)))
1338 1338  
1339 1339  
1340 1340  [[image:image-20220602175818-12.png]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0