Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -103,7 +103,6 @@ 103 103 * Support Modbus protocol 104 104 * Support Interrupt uplink (Since hardware version v1.2) 105 105 106 - 107 107 == 1.4 Applications == 108 108 109 109 * Smart Buildings & Home Automation ... ... @@ -113,7 +113,6 @@ 113 113 * Smart Cities 114 114 * Smart Factory 115 115 116 - 117 117 == 1.5 Firmware Change log == 118 118 119 119 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -307,8 +307,6 @@ 307 307 ))) 308 308 ))) 309 309 310 - 311 - 312 312 === 3.3.2 Configure sensors === 313 313 314 314 ((( ... ... @@ -327,8 +327,6 @@ 327 327 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 328 328 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 329 329 330 - 331 - 332 332 === 3.3.3 Configure read commands for each sampling === 333 333 334 334 ((( ... ... @@ -548,6 +548,7 @@ 548 548 549 549 550 550 545 + 551 551 ==== **RS485 Debug Command** ==== 552 552 553 553 ((( ... ... @@ -668,6 +668,7 @@ 668 668 669 669 670 670 666 + 671 671 ==== **Set Payload version** ==== 672 672 673 673 ((( ... ... @@ -699,66 +699,129 @@ 699 699 700 700 701 701 698 + 702 702 ==== **Set RS485 Sampling Commands** ==== 703 703 701 +((( 704 704 AT+COMMANDx or AT+DATACUTx 703 +))) 705 705 705 +((( 706 706 These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 707 +))) 707 707 709 +((( 710 + 711 +))) 708 708 709 -* **AT Command:** 713 +* ((( 714 +**AT Command:** 715 +))) 710 710 711 711 (% class="box infomessage" %) 712 712 ((( 719 +((( 713 713 **AT+COMMANDx: Configure RS485 read command to sensor.** 714 714 ))) 722 +))) 715 715 716 716 (% class="box infomessage" %) 717 717 ((( 726 +((( 718 718 **AT+DATACUTx: Configure how to handle return from RS485 devices.** 719 719 ))) 729 +))) 720 720 731 +((( 732 + 733 +))) 721 721 722 -* **Downlink Payload:** 735 +* ((( 736 +**Downlink Payload:** 737 +))) 723 723 739 +((( 724 724 **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 741 +))) 725 725 743 +((( 726 726 (% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 745 +))) 727 727 747 +((( 728 728 Format: AF MM NN LL XX XX XX XX YY 749 +))) 729 729 751 +((( 730 730 Where: 753 +))) 731 731 732 -* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 733 -* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 734 -* LL: The length of AT+COMMAND or AT+DATACUT command 735 -* XX XX XX XX: AT+COMMAND or AT+DATACUT command 736 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 755 +* ((( 756 +MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 757 +))) 758 +* ((( 759 +NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 760 +))) 761 +* ((( 762 +LL: The length of AT+COMMAND or AT+DATACUT command 763 +))) 764 +* ((( 765 +XX XX XX XX: AT+COMMAND or AT+DATACUT command 766 +))) 767 +* ((( 768 +YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 769 +))) 737 737 771 +((( 738 738 **Example:** 773 +))) 739 739 775 +((( 740 740 (% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1 777 +))) 741 741 779 +((( 742 742 (% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10** 781 +))) 743 743 783 +((( 744 744 (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10** 785 +))) 745 745 746 746 747 747 789 + 748 748 ==== **Fast command to handle MODBUS device** ==== 749 749 792 +((( 750 750 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 794 +))) 751 751 796 +((( 752 752 This command is valid since v1.3 firmware version 798 +))) 753 753 800 +((( 754 754 AT+MBFUN can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 802 +))) 755 755 804 +((( 805 + 806 +))) 756 756 808 +((( 757 757 **Example:** 810 +))) 758 758 759 -* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 760 -* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 761 -* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 812 +* ((( 813 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 814 +))) 815 +* ((( 816 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 817 +))) 818 +* ((( 819 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 820 +))) 762 762 763 763 [[image:image-20220602165351-6.png]] 764 764 ... ... @@ -766,201 +766,376 @@ 766 766 767 767 768 768 828 + 769 769 ==== **RS485 command timeout** ==== 770 770 831 +((( 771 771 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. 833 +))) 772 772 835 +((( 773 773 Default value: 0, range: 0 ~~ 65 seconds 837 +))) 774 774 775 -* **AT Command:** 839 +* ((( 840 +**AT Command:** 841 +))) 776 776 777 777 (% class="box infomessage" %) 778 778 ((( 845 +((( 779 779 **AT+CMDDLaa=hex(bb cc)*1000** 780 780 ))) 848 +))) 781 781 850 +((( 782 782 **Example:** 852 +))) 783 783 854 +((( 784 784 **AT+CMDDL1=1000** to send the open time to 1000ms 856 +))) 785 785 858 +((( 859 + 860 +))) 786 786 787 -* **Downlink Payload:** 862 +* ((( 863 +**Downlink Payload:** 864 +))) 788 788 866 +((( 789 789 **0x AA aa bb cc** 868 +))) 790 790 870 +((( 791 791 Same as: AT+CMDDLaa=hex(bb cc)*1000 872 +))) 792 792 874 +((( 793 793 **Example:** 876 +))) 794 794 878 +((( 795 795 0xAA 01 00 01 ~-~-> Same as **AT+CMDDL1=1000 ms** 880 +))) 796 796 797 797 798 798 884 + 799 799 ==== **Uplink payload mode** ==== 800 800 887 +((( 801 801 Define to use one uplink or multiple uplinks for the sampling. 889 +))) 802 802 891 +((( 803 803 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 893 +))) 804 804 805 -* **AT Command:** 895 +* ((( 896 +**AT Command:** 897 +))) 806 806 807 807 (% class="box infomessage" %) 808 808 ((( 901 +((( 809 809 **AT+DATAUP=0** 810 810 ))) 904 +))) 811 811 812 812 (% class="box infomessage" %) 813 813 ((( 908 +((( 814 814 **AT+DATAUP=1** 815 815 ))) 911 +))) 816 816 913 +((( 914 + 915 +))) 817 817 818 -* **Downlink Payload:** 917 +* ((( 918 +**Downlink Payload:** 919 +))) 819 819 921 +((( 820 820 **0xAD 00** **~-~->** Same as AT+DATAUP=0 923 +))) 821 821 925 +((( 822 822 **0xAD 01** **~-~->** Same as AT+DATAUP=1 927 +))) 823 823 824 824 825 825 931 + 826 826 ==== **Manually trigger an Uplink** ==== 827 827 934 +((( 828 828 Ask device to send an uplink immediately. 936 +))) 829 829 830 -* **AT Command:** 938 +* ((( 939 +**AT Command:** 940 +))) 831 831 942 +((( 832 832 No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same. 944 +))) 833 833 946 +((( 947 + 948 +))) 834 834 835 -* **Downlink Payload:** 950 +* ((( 951 +**Downlink Payload:** 952 +))) 836 836 954 +((( 837 837 **0x08 FF**, RS485-LN will immediately send an uplink. 956 +))) 838 838 839 839 840 840 960 + 841 841 ==== **Clear RS485 Command** ==== 842 842 963 +((( 843 843 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 965 +))) 844 844 845 -* **AT Command:** 967 +* ((( 968 +**AT Command:** 969 +))) 846 846 971 +((( 847 847 **AT+CMDEAR=mm,nn** mm: start position of erase ,nn: stop position of erase 973 +))) 848 848 975 +((( 849 849 Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 977 +))) 850 850 979 +((( 851 851 Example screen shot after clear all RS485 commands. 981 +))) 852 852 983 +((( 984 + 985 +))) 853 853 987 +((( 854 854 The uplink screen shot is: 989 +))) 855 855 856 856 [[image:1654160691922-496.png]] 857 857 858 858 859 -* **Downlink Payload:** 994 +* ((( 995 +**Downlink Payload:** 996 +))) 860 860 998 +((( 861 861 **0x09 aa bb** same as AT+CMDEAR=aa,bb 1000 +))) 862 862 863 863 864 864 1004 + 865 865 ==== **Set Serial Communication Parameters** ==== 866 866 1007 +((( 867 867 Set the Rs485 serial communication parameters: 1009 +))) 868 868 869 -* **AT Command:** 1011 +* ((( 1012 +**AT Command:** 1013 +))) 870 870 1015 +((( 871 871 Set Baud Rate: 1017 +))) 872 872 873 873 (% class="box infomessage" %) 874 874 ((( 1021 +((( 875 875 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 876 876 ))) 1024 +))) 877 877 1026 +((( 878 878 Set UART Parity 1028 +))) 879 879 880 880 (% class="box infomessage" %) 881 881 ((( 1032 +((( 882 882 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 883 883 ))) 1035 +))) 884 884 1037 +((( 885 885 Set STOPBIT 1039 +))) 886 886 887 887 (% class="box infomessage" %) 888 888 ((( 1043 +((( 889 889 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 890 890 ))) 1046 +))) 891 891 1048 +((( 1049 + 1050 +))) 892 892 893 -* **Downlink Payload:** 1052 +* ((( 1053 +**Downlink Payload:** 1054 +))) 894 894 1056 +((( 895 895 **A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1058 +))) 896 896 1060 +((( 897 897 **Example:** 1062 +))) 898 898 899 -* A7 01 00 60 same as AT+BAUDR=9600 900 -* A7 01 04 80 same as AT+BAUDR=115200 1064 +* ((( 1065 +A7 01 00 60 same as AT+BAUDR=9600 1066 +))) 1067 +* ((( 1068 +A7 01 04 80 same as AT+BAUDR=115200 1069 +))) 901 901 1071 +((( 902 902 A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1073 +))) 903 903 1075 +((( 904 904 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1077 +))) 905 905 906 906 1080 + 1081 + 907 907 == 3.6 Listening mode for RS485 network == 908 908 1084 +((( 909 909 This feature support since firmware v1.4 1086 +))) 910 910 1088 +((( 911 911 RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN. 1090 +))) 912 912 913 913 [[image:image-20220602171200-8.png||height="567" width="1007"]] 914 914 1094 +((( 915 915 To enable the listening mode, use can run the command AT+RXMODE. 1096 +))) 916 916 1098 +((( 1099 + 1100 +))) 917 917 918 -(% border="1" style="background-color:#ffffcc; width:500px" %) 919 -|=(% style="width: 161px;" %)**Command example:**|=(% style="width: 337px;" %)**Function** 920 -|(% style="width:161px" %)AT+RXMODE=1,10 |(% style="width:337px" %)Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 921 -|(% style="width:161px" %)AT+RXMODE=2,500|(% style="width:337px" %)Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 922 -|(% style="width:161px" %)AT+RXMODE=0,0|(% style="width:337px" %)Disable listening mode. This is the default settings. 923 -|(% style="width:161px" %) |(% style="width:337px" %)A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 ~| cc) 1102 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1103 +|=(% style="width: 161px;" %)((( 1104 +**Command example:** 1105 +)))|=(% style="width: 337px;" %)((( 1106 +**Function** 1107 +))) 1108 +|(% style="width:161px" %)((( 1109 +AT+RXMODE=1,10 1110 +)))|(% style="width:337px" %)((( 1111 +Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1112 +))) 1113 +|(% style="width:161px" %)((( 1114 +AT+RXMODE=2,500 1115 +)))|(% style="width:337px" %)((( 1116 +Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1117 +))) 1118 +|(% style="width:161px" %)((( 1119 +AT+RXMODE=0,0 1120 +)))|(% style="width:337px" %)((( 1121 +Disable listening mode. This is the default settings. 1122 +))) 1123 +|(% style="width:161px" %)((( 1124 + 1125 +)))|(% style="width:337px" %)((( 1126 +A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1127 +))) 924 924 1129 +((( 925 925 **Downlink Command:** 1131 +))) 926 926 1133 +((( 927 927 **0xA6 aa bb cc ** same as AT+RXMODE=aa,(bb<<8 | cc) 1135 +))) 928 928 1137 +((( 1138 + 1139 +))) 929 929 1141 +((( 930 930 **Example**: 1143 +))) 931 931 1145 +((( 932 932 The RS485-LN is set to AT+RXMODE=2,1000 1147 +))) 933 933 1149 +((( 934 934 There is a two Modbus commands in the RS485 network as below: 1151 +))) 935 935 1153 +((( 936 936 The Modbus master send a command: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b 1155 +))) 937 937 1157 +((( 938 938 And Modbus slave reply with: (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 1159 +))) 939 939 1161 +((( 940 940 RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33 1163 +))) 941 941 1165 +((( 942 942 [[image:image-20220602171200-9.png]] 1167 +))) 943 943 1169 +((( 1170 + 1171 +))) 944 944 1173 +((( 945 945 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1175 +))) 946 946 947 947 948 948 == 3.7 Buttons == 949 949 950 950 951 -(% border="1" style="background-color:#f7faff; width: 500px" %)952 -|=**Button**|=(% style="width: 1420px;" %)**Feature**953 -|**ACT**|(% style="width: 1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**954 -|**RST**|(% style="width: 1420px" %)Reboot RS485955 -|**PRO**|(% style="width: 1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]1181 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %) 1182 +|=(% style="width: 30px;" %)**Button**|=(% style="width: 355px;" %)**Feature** 1183 +|=(% style="width: 30px;" %)**ACT**|(% style="width:355px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink** 1184 +|=(% style="width: 30px;" %)**RST**|(% style="width:355px" %)Reboot RS485 1185 +|=(% style="width: 30px;" %)**PRO**|(% style="width:355px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 956 956 1187 + 1188 + 957 957 == 3.8 LEDs == 958 958 959 -(% border="1" style="background-color:#f7faff; width:500px" %) 960 -|=**LEDs**|=**Feature** 961 -|**PWR**|Always on if there is power 962 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %) **fast blink in GREEN**(%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**.**SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.1191 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %) 1192 +|=(% style="width: 30px;" %)**LEDs**|=(% style="width: 400px;" %)**Feature** 1193 +|(% style="width:30px" %)**PWR**|=(% style="width: 400px;" %)Always on if there is power 1194 +|(% style="width:30px" %)**SYS**|=(% style="width: 400px;" %)After device is powered on, the SYS will (% style="color:green" %)fast blink in GREEN (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)on GREEN for 5 seconds(%%). SYS will (% style="color:green" %)blink Blue(%%) on every upload and (% style="color:green" %)blink Green(%%) once receive a downlink message. 963 963 1196 + 1197 + 964 964 = 4. Case Study = 965 965 966 966 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -970,19 +970,26 @@ 970 970 971 971 == 5.1 Access AT Command == 972 972 1207 +((( 973 973 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1209 +))) 974 974 975 975 [[image:1654162355560-817.png]] 976 976 977 977 1214 +((( 978 978 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1216 +))) 979 979 980 980 [[image:1654162368066-342.png]] 981 981 982 982 1221 +((( 983 983 More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1223 +))) 984 984 985 985 1226 + 986 986 == 5.2 Common AT Command Sequence == 987 987 988 988 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === ... ... @@ -1137,7 +1137,6 @@ 1137 1137 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1138 1138 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1139 1139 1140 - 1141 1141 = 9.Packing Info = 1142 1142 1143 1143 ... ... @@ -1154,7 +1154,6 @@ 1154 1154 * Package Size / pcs : 14.5 x 8 x 5 cm 1155 1155 * Weight / pcs : 170g 1156 1156 1157 - 1158 1158 = 10. FCC Caution for RS485LN-US915 = 1159 1159 1160 1160 (((