<
From version < 58.4 >
edited by Xiaoling
on 2022/06/06 11:21
To version < 58.10 >
edited by Xiaoling
on 2022/06/06 11:22
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -548,6 +548,7 @@
548 548  
549 549  
550 550  
551 +
551 551  ==== **RS485 Debug Command** ====
552 552  
553 553  (((
... ... @@ -668,85 +668,161 @@
668 668  
669 669  
670 670  
672 +
671 671  ==== **Set Payload version** ====
672 672  
675 +(((
673 673  This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
677 +)))
674 674  
675 -* **AT Command:**
679 +* (((
680 +**AT Command:**
681 +)))
676 676  
677 677  (% class="box infomessage" %)
678 678  (((
685 +(((
679 679  **AT+PAYVER: Set PAYVER field = 1**
680 680  )))
688 +)))
681 681  
682 -* **Downlink Payload:**
690 +* (((
691 +**Downlink Payload:**
692 +)))
683 683  
694 +(((
684 684  **0xAE 01**  ~-~-> Set PAYVER field =  0x01
696 +)))
685 685  
698 +(((
686 686  **0xAE 0F**   ~-~-> Set PAYVER field =  0x0F
700 +)))
687 687  
688 688  
689 689  
704 +
690 690  ==== **Set RS485 Sampling Commands** ====
691 691  
707 +(((
692 692  AT+COMMANDx or AT+DATACUTx
709 +)))
693 693  
711 +(((
694 694  These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
713 +)))
695 695  
715 +(((
716 +
717 +)))
696 696  
697 -* **AT Command:**
719 +* (((
720 +**AT Command:**
721 +)))
698 698  
699 699  (% class="box infomessage" %)
700 700  (((
725 +(((
701 701  **AT+COMMANDx: Configure RS485 read command to sensor.**
702 702  )))
728 +)))
703 703  
704 704  (% class="box infomessage" %)
705 705  (((
732 +(((
706 706  **AT+DATACUTx: Configure how to handle return from RS485 devices.**
707 707  )))
735 +)))
708 708  
737 +(((
738 +
739 +)))
709 709  
710 -* **Downlink Payload:**
741 +* (((
742 +**Downlink Payload:**
743 +)))
711 711  
745 +(((
712 712  **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
747 +)))
713 713  
749 +(((
714 714  (% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
751 +)))
715 715  
753 +(((
716 716  Format: AF MM NN LL XX XX XX XX YY
755 +)))
717 717  
757 +(((
718 718  Where:
759 +)))
719 719  
720 -* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
721 -* NN:  0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
722 -* LL:  The length of AT+COMMAND or AT+DATACUT command
723 -* XX XX XX XX: AT+COMMAND or AT+DATACUT command
724 -* YY:  If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.
761 +* (((
762 +MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
763 +)))
764 +* (((
765 +NN:  0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
766 +)))
767 +* (((
768 +LL:  The length of AT+COMMAND or AT+DATACUT command
769 +)))
770 +* (((
771 +XX XX XX XX: AT+COMMAND or AT+DATACUT command
772 +)))
773 +* (((
774 +YY:  If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.
775 +)))
725 725  
777 +(((
726 726  **Example:**
779 +)))
727 727  
781 +(((
728 728  (% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1
783 +)))
729 729  
785 +(((
730 730  (% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10**
787 +)))
731 731  
789 +(((
732 732  (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10**
791 +)))
733 733  
734 734  
735 735  
795 +
736 736  ==== **Fast command to handle MODBUS device** ====
737 737  
798 +(((
738 738  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
800 +)))
739 739  
802 +(((
740 740  This command is valid since v1.3 firmware version
804 +)))
741 741  
806 +(((
742 742  AT+MBFUN can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore.
808 +)))
743 743  
810 +(((
811 +
812 +)))
744 744  
814 +(((
745 745  **Example:**
816 +)))
746 746  
747 -* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
748 -* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
749 -* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
818 +* (((
819 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
820 +)))
821 +* (((
822 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
823 +)))
824 +* (((
825 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
826 +)))
750 750  
751 751  [[image:image-20220602165351-6.png]]
752 752  
... ... @@ -756,31 +756,56 @@
756 756  
757 757  ==== **RS485 command timeout** ====
758 758  
836 +(((
759 759  Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
838 +)))
760 760  
840 +(((
761 761  Default value: 0, range:  0 ~~ 65 seconds
842 +)))
762 762  
763 -* **AT Command:**
844 +* (((
845 +**AT Command:**
846 +)))
764 764  
765 765  (% class="box infomessage" %)
766 766  (((
850 +(((
767 767  **AT+CMDDLaa=hex(bb cc)*1000**
768 768  )))
853 +)))
769 769  
855 +(((
770 770  **Example:**
857 +)))
771 771  
859 +(((
772 772  **AT+CMDDL1=1000** to send the open time to 1000ms
861 +)))
773 773  
863 +(((
864 +
865 +)))
774 774  
775 -* **Downlink Payload:**
867 +* (((
868 +**Downlink Payload:**
869 +)))
776 776  
871 +(((
777 777  **0x AA aa bb cc**
873 +)))
778 778  
875 +(((
779 779  Same as: AT+CMDDLaa=hex(bb cc)*1000
877 +)))
780 780  
879 +(((
781 781   **Example:**
881 +)))
782 782  
883 +(((
783 783   0xAA 01 00 01  ~-~-> Same as **AT+CMDDL1=1000 ms**
885 +)))
784 784  
785 785  
786 786  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0