28 28  The Dragino RS485-LN is a (% style="color:blue" %)**RS485 to LoRaWAN Converter**(%%). It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost.
29 29  )))
30 -)))
31 31  
32 32  (((
33 -(((
34 34  RS485-LN allows user to (% style="color:blue" %)**monitor / control RS485 devices**(%%) and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on.
35 35  )))
36 -)))
37 37  
38 38  (((
39 -(((
40 40  (% style="color:blue" %)**For data uplink**(%%), RS485-LN sends user-defined commands to RS485 devices and gets the return from the RS485 devices. RS485-LN will process these returns according to user-define rules to get the final payload and upload to LoRaWAN server.
41 41  )))
42 -)))
43 43  
44 44  (((
45 -(((
46 46  (% style="color:blue" %)**For data downlink**(%%), RS485-LN runs in LoRaWAN Class C. When there downlink commands from LoRaWAN server, RS485-LN will forward the commands from LoRaWAN server to RS485 devices.
47 -)))
48 48  
49 -(((
50 50  (% style="color:blue" %)**Demo Dashboard for RS485-LN**(%%) connect to two energy meters: [[https:~~/~~/app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a>>url:https://app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a]]
51 51  )))
52 52  )))
53 -)))
54 54  
55 55  [[image:1653267211009-519.png||height="419" width="724"]]
56 56  
... ... @@ -103,7 +103,6 @@
103 103  * Support Modbus protocol
104 104  * Support Interrupt uplink (Since hardware version v1.2)
105 105  
106 -
107 107  == 1.4 Applications ==
108 108  
109 109  * Smart Buildings & Home Automation
... ... @@ -113,7 +113,6 @@
113 113  * Smart Cities
114 114  * Smart Factory
115 115  
116 -
117 117  == 1.5 Firmware Change log ==
118 118  
119 119  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -123,13 +123,9 @@
123 123  
124 124  (((
125 125  (((
126 -(((
127 127  v1.2: Add External Interrupt Pin.
128 -)))
129 129  
130 -(((
131 131  v1.0: Release
132 -)))
133 133  
134 134  
135 135  )))
... ... @@ -157,9 +157,7 @@
157 157  == 3.1 How it works? ==
158 158  
159 159  (((
160 -(((
161 161  The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA.
162 -)))
163 163  
164 164  
165 165  )))
... ... @@ -249,19 +249,19 @@
249 249  
250 250  To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
251 251  
252 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
253 -|=(% style="width: 110px;" %)(((
234 +(% border="1" style="background-color:#ffffcc; color:green; width:782px" %)
235 +|(% style="width:128px" %)(((
254 254  **AT Commands**
255 -)))|=(% style="width: 190px;" %)(((
237 +)))|(% style="width:305px" %)(((
256 256  **Description**
257 -)))|=(% style="width: 190px;" %)(((
239 +)))|(% style="width:346px" %)(((
258 258  **Example**
259 259  )))
260 -|(% style="width:110px" %)(((
242 +|(% style="width:128px" %)(((
261 261  AT+BAUDR
262 -)))|(% style="width:190px" %)(((
244 +)))|(% style="width:305px" %)(((
263 263  Set the baud rate (for RS485 connection). Default Value is: 9600.
264 -)))|(% style="width:190px" %)(((
246 +)))|(% style="width:346px" %)(((
265 265  (((
266 266  AT+BAUDR=9600
267 267  )))
... ... @@ -270,11 +270,11 @@
270 270  Options: (1200,2400,4800,14400,19200,115200)
271 271  )))
272 272  )))
273 -|(% style="width:110px" %)(((
255 +|(% style="width:128px" %)(((
274 274  AT+PARITY
275 -)))|(% style="width:190px" %)(((
257 +)))|(% style="width:305px" %)(((
276 276  Set UART parity (for RS485 connection)
277 -)))|(% style="width:190px" %)(((
259 +)))|(% style="width:346px" %)(((
278 278  (((
279 279  AT+PARITY=0
280 280  )))
... ... @@ -283,9 +283,9 @@
283 283  Option: 0: no parity, 1: odd parity, 2: even parity
284 284  )))
285 285  )))
286 -|(% style="width:110px" %)(((
268 +|(% style="width:128px" %)(((
287 287  AT+STOPBIT
288 -)))|(% style="width:190px" %)(((
270 +)))|(% style="width:305px" %)(((
289 289  (((
290 290  Set serial stopbit (for RS485 connection)
291 291  )))
... ... @@ -293,7 +293,7 @@
293 293  (((
294 294  
295 295  )))
296 -)))|(% style="width:190px" %)(((
278 +)))|(% style="width:346px" %)(((
297 297  (((
298 298  AT+STOPBIT=0 for 1bit
299 299  )))
... ... @@ -307,8 +307,6 @@
307 307  )))
308 308  )))
309 309  
310 -
311 -
312 312  === 3.3.2 Configure sensors ===
313 313  
314 314  (((
... ... @@ -317,18 +317,16 @@
317 317  )))
318 318  )))
319 319  
320 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
321 -|=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
322 -|AT+CFGDEV|(% style="width:110px" %)(((
300 +(% border="1" style="background-color:#ffffcc; color:green; width:806px" %)
301 +|**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example**
302 +|AT+CFGDEV|(% style="width:418px" %)(((
323 323  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
324 324  
325 325  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
326 326  
327 327  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
328 -)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
308 +)))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
329 329  
330 -
331 -
332 332  === 3.3.3 Configure read commands for each sampling ===
333 333  
334 334  (((
... ... @@ -374,8 +374,8 @@
374 374  
375 375  **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
376 376  
377 -(% border="1" style="background-color:#4bacc6; color:white; width:510px" %)
378 -|(% style="width:510px" %)(((
355 +(% border="1" style="background-color:#4bacc6; color:white; width:725px" %)
356 +|(% style="width:722px" %)(((
379 379  **AT+DATACUTx=a,b,c**
380 380  
381 381  * **a: length for the return of AT+COMMAND**
... ... @@ -501,35 +501,33 @@
501 501  
502 502  == 3.4 Uplink Payload ==
503 503  
482 +(% border="1" style="background-color:#4bacc6; color:white; width:734px" %)
483 +|**Size(bytes)**|(% style="width:120px" %)**2**|(% style="width:116px" %)**1**|(% style="width:386px" %)**Length depends on the return from the commands**
484 +|Value|(% style="width:120px" %)(((
485 +Battery(mV)
504 504  
505 -[[image:image-20220606110929-1.png]]
487 +&
506 506  
489 +Interrupt _Flag
490 +)))|(% style="width:116px" %)(((
491 +PAYLOAD_VER
492 +
493 +
494 +)))|(% style="width:386px" %)If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server.
495 +
507 507  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
508 508  
509 509  
510 510  == 3.5 Configure RS485-BL via AT or Downlink ==
511 511  
512 -(((
513 513  User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands
514 -)))
515 515  
516 -(((
517 517  There are two kinds of Commands:
518 -)))
519 519  
520 -* (((
521 -(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
522 -)))
505 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
523 523  
524 -* (((
525 -(% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
526 -)))
507 +* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
527 527  
528 -(((
529 -
530 -)))
531 -
532 -
533 533  === 3.5.1 Common Commands ===
534 534  
535 535  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -550,121 +550,58 @@
550 550  
551 551  ==== **RS485 Debug Command** ====
552 552  
553 -(((
554 554  This command is used to configure the RS485 devices; they won’t be used during sampling.
555 -)))
556 556  
557 -* (((
558 -**AT Command**
559 -)))
531 +* **AT Command**
560 560  
561 561  (% class="box infomessage" %)
562 562  (((
563 -(((
564 564  **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
565 565  )))
566 -)))
567 567  
568 -(((
569 569  m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
570 -)))
571 571  
572 -* (((
573 -**Downlink Payload**
574 -)))
540 +* **Downlink Payload**
575 575  
576 -(((
577 577  Format: A8 MM NN XX XX XX XX YY
578 -)))
579 579  
580 -(((
581 581  Where:
582 -)))
583 583  
584 -* (((
585 -MM: 1: add CRC-16/MODBUS ; 0: no CRC
586 -)))
587 -* (((
588 -NN: The length of RS485 command
589 -)))
590 -* (((
591 -XX XX XX XX: RS485 command total NN bytes
592 -)))
593 -* (((
594 -(((
595 -YY: How many bytes will be uplink from the return of this RS485 command,
596 -)))
546 +* MM: 1: add CRC-16/MODBUS ; 0: no CRC
547 +* NN: The length of RS485 command
548 +* XX XX XX XX: RS485 command total NN bytes
549 +* YY: How many bytes will be uplink from the return of this RS485 command,
550 +** if YY=0, RS485-LN will execute the downlink command without uplink;
551 +** if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200
552 +** if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200.
597 597  
598 -* (((
599 -if YY=0, RS485-LN will execute the downlink command without uplink;
600 -)))
601 -* (((
602 -if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200
603 -)))
604 -* (((
605 -if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200.
606 -)))
607 -)))
608 -
609 -(((
610 610  **Example 1** ~-~-> Configure without ask for uplink (YY=0)
611 -)))
612 612  
613 -(((
614 614  To connect a Modbus Alarm with below commands.
615 -)))
616 616  
617 -* (((
618 -The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
619 -)))
558 +* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
620 620  
621 -* (((
622 -The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
623 -)))
560 +* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
624 624  
625 -(((
626 626  So if user want to use downlink command to control to RS485 Alarm, he can use:
627 -)))
628 628  
629 -(((
630 630  (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm
631 -)))
632 632  
633 -(((
634 634  (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm
635 -)))
636 636  
637 -(((
638 638  A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
639 -)))
640 640  
641 -(((
642 -
643 -)))
644 644  
645 -(((
646 646  **Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
647 -)))
648 648  
649 -(((
650 650  User in IoT server send a downlink command: (% style="color:#4f81bd" %)**A8 01 06 0A 08 00 04 00 01 YY**
651 -)))
652 652  
653 -(((
654 -
655 -)))
656 656  
657 -(((
658 658  RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:
659 -)))
660 660  
661 -(((
662 662   **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
663 -)))
664 664  
665 -(((
666 666   [[image:1654159460680-153.png]]
667 -)))
668 668  
669 669  
670 670  
... ... @@ -942,6 +942,7 @@
942 942  |**RST**|(% style="width:1420px" %)Reboot RS485
943 943  |**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
944 944  
858 +
945 945  == 3.8 LEDs ==
946 946  
947 947  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -949,6 +949,7 @@
949 949  |**PWR**|Always on if there is power
950 950  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
951 951  
866 +
952 952  = 4. Case Study =
953 953  
954 954  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1126,6 +1126,7 @@
1126 1126  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1127 1127  
1128 1128  
1044 +
1129 1129  = 9.Packing Info =
1130 1130  
1131 1131  
... ... @@ -1142,63 +1142,32 @@
1142 1142  * Package Size / pcs : 14.5 x 8 x 5 cm
1143 1143  * Weight / pcs : 170g
1144 1144  
1145 -
1146 1146  = 10. FCC Caution for RS485LN-US915 =
1147 1147  
1148 -(((
1149 1149  Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
1150 -)))
1151 1151  
1152 -(((
1153 1153  This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
1154 -)))
1155 1155  
1156 -(((
1157 -
1158 -)))
1159 1159  
1160 -(((
1161 1161  **IMPORTANT NOTE:**
1162 -)))
1163 1163  
1164 -(((
1165 1165  **Note: **This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1166 -)))
1167 1167  
1168 -(((
1169 1169  —Reorient or relocate the receiving antenna.
1170 -)))
1171 1171  
1172 -(((
1173 1173  —Increase the separation between the equipment and receiver.
1174 -)))
1175 1175  
1176 -(((
1177 1177  —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
1178 -)))
1179 1179  
1180 -(((
1181 1181  —Consult the dealer or an experienced radio/TV technician for help.
1182 -)))
1183 1183  
1184 -(((
1185 -
1186 -)))
1187 1187  
1188 -(((
1189 1189  **FCC Radiation Exposure Statement:**
1190 -)))
1191 1191  
1192 -(((
1193 1193  This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.
1194 -)))
1195 1195  
1196 1196  
1197 1197  = 11. Support =
1198 1198  
1199 -* (((
1200 -Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1201 -)))
1202 -* (((
1203 -Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
1204 -)))
1088 +* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1089 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].