Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -233,11 +233,15 @@ 233 233 234 234 ((( 235 235 ((( 236 +((( 236 236 There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 237 237 ))) 239 +))) 238 238 239 239 ((( 242 +((( 240 240 (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 244 +))) 241 241 242 242 243 243 ))) ... ... @@ -305,6 +305,7 @@ 305 305 ))) 306 306 ))) 307 307 312 + 308 308 === 3.3.2 Configure sensors === 309 309 310 310 ((( ... ... @@ -323,6 +323,7 @@ 323 323 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 324 324 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 325 325 331 + 326 326 === 3.3.3 Configure read commands for each sampling === 327 327 328 328 ((( ... ... @@ -1100,29 +1100,29 @@ 1100 1100 ))) 1101 1101 1102 1102 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 1103 -|=(% style="width: 1 61px;" %)(((1104 -**Command example :**1105 -)))|=(% style="width: 337px;" %)(((1109 +|=(% style="width: 100px;" %)((( 1110 +**Command example** 1111 +)))|=(% style="width: 400px;" %)((( 1106 1106 **Function** 1107 1107 ))) 1108 -|(% style="width:1 61px" %)(((1114 +|(% style="width:100px" %)((( 1109 1109 AT+RXMODE=1,10 1110 -)))|(% style="width: 337px" %)(((1116 +)))|(% style="width:400px" %)((( 1111 1111 Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks. 1112 1112 ))) 1113 -|(% style="width:1 61px" %)(((1119 +|(% style="width:100px" %)((( 1114 1114 AT+RXMODE=2,500 1115 -)))|(% style="width: 337px" %)(((1121 +)))|(% style="width:400px" %)((( 1116 1116 Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms 1117 1117 ))) 1118 -|(% style="width:1 61px" %)(((1124 +|(% style="width:100px" %)((( 1119 1119 AT+RXMODE=0,0 1120 -)))|(% style="width: 337px" %)(((1126 +)))|(% style="width:400px" %)((( 1121 1121 Disable listening mode. This is the default settings. 1122 1122 ))) 1123 -|(% style="width:1 61px" %)(((1129 +|(% style="width:100px" %)((( 1124 1124 1125 -)))|(% style="width: 337px" %)(((1131 +)))|(% style="width:400px" %)((( 1126 1126 A6 aa bb cc same as AT+RXMODE=aa,(bb<<8 | cc) 1127 1127 ))) 1128 1128 ... ... @@ -1171,8 +1171,10 @@ 1171 1171 ))) 1172 1172 1173 1173 ((( 1180 +((( 1174 1174 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while. 1175 1175 ))) 1183 +))) 1176 1176 1177 1177 1178 1178 == 3.7 Buttons == ... ... @@ -1184,6 +1184,7 @@ 1184 1184 |(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485 1185 1185 |(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1186 1186 1195 + 1187 1187 == 3.8 LEDs == 1188 1188 1189 1189