<
From version < 58.39 >
edited by Xiaoling
on 2022/06/06 12:01
To version < 58.24 >
edited by Xiaoling
on 2022/06/06 11:26
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -103,6 +103,7 @@
103 103  * Support Modbus protocol
104 104  * Support Interrupt uplink (Since hardware version v1.2)
105 105  
106 +
106 106  == 1.4 Applications ==
107 107  
108 108  * Smart Buildings & Home Automation
... ... @@ -112,6 +112,7 @@
112 112  * Smart Cities
113 113  * Smart Factory
114 114  
116 +
115 115  == 1.5 Firmware Change log ==
116 116  
117 117  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -305,6 +305,8 @@
305 305  )))
306 306  )))
307 307  
310 +
311 +
308 308  === 3.3.2 Configure sensors ===
309 309  
310 310  (((
... ... @@ -323,6 +323,8 @@
323 323  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
324 324  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
325 325  
330 +
331 +
326 326  === 3.3.3 Configure read commands for each sampling ===
327 327  
328 328  (((
... ... @@ -1178,21 +1178,23 @@
1178 1178  == 3.7 Buttons ==
1179 1179  
1180 1180  
1181 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:400px" %)
1182 -|=(% style="width: 50px;" %)**Button**|=(% style="width: 350px;" %)**Feature**
1183 -|(% style="width:50px" %)**ACT**|(% style="width:350px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1184 -|(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485
1185 -|(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1187 +(% border="1" style="background-color:#f7faff; width:500px" %)
1188 +|=**Button**|=(% style="width: 1420px;" %)**Feature**
1189 +|**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1190 +|**RST**|(% style="width:1420px" %)Reboot RS485
1191 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1186 1186  
1187 -== 3.8 LEDs ==
1188 1188  
1189 1189  
1190 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1191 -|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature**
1195 +== 3.8 LEDs ==
1196 +
1197 +(% border="1" style="background-color:#f7faff; width:500px" %)
1198 +|=**LEDs**|=**Feature**
1192 1192  |**PWR**|Always on if there is power
1193 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1200 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1194 1194  
1195 1195  
1203 +
1196 1196  = 4. Case Study =
1197 1197  
1198 1198  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1202,26 +1202,19 @@
1202 1202  
1203 1203  == 5.1 Access AT Command ==
1204 1204  
1205 -(((
1206 1206  RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1207 -)))
1208 1208  
1209 1209  [[image:1654162355560-817.png]]
1210 1210  
1211 1211  
1212 -(((
1213 1213  In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1214 -)))
1215 1215  
1216 1216  [[image:1654162368066-342.png]]
1217 1217  
1218 1218  
1219 -(((
1220 1220  More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1221 -)))
1222 1222  
1223 1223  
1224 -
1225 1225  == 5.2 Common AT Command Sequence ==
1226 1226  
1227 1227  === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
... ... @@ -1295,23 +1295,13 @@
1295 1295  
1296 1296  == 6.1 How to upgrade the image? ==
1297 1297  
1298 -(((
1299 1299  The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to:
1300 -)))
1301 1301  
1302 -* (((
1303 -Support new features
1304 -)))
1305 -* (((
1306 -For bug fix
1307 -)))
1308 -* (((
1309 -Change LoRaWAN bands.
1310 -)))
1301 +* Support new features
1302 +* For bug fix
1303 +* Change LoRaWAN bands.
1311 1311  
1312 -(((
1313 1313  Below shows the hardware connection for how to upload an image to RS485-LN:
1314 -)))
1315 1315  
1316 1316  [[image:1654162535040-878.png]]
1317 1317  
... ... @@ -1322,10 +1322,8 @@
1322 1322  **Step3: **Open flashloader; choose the correct COM port to update.
1323 1323  
1324 1324  (((
1325 -(((
1326 1326  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1327 1327  )))
1328 -)))
1329 1329  
1330 1330  
1331 1331  [[image:image-20220602175818-12.png]]
... ... @@ -1388,6 +1388,7 @@
1388 1388  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1389 1389  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1390 1390  
1380 +
1391 1391  = 9.Packing Info =
1392 1392  
1393 1393  
... ... @@ -1404,6 +1404,7 @@
1404 1404  * Package Size / pcs : 14.5 x 8 x 5 cm
1405 1405  * Weight / pcs : 170g
1406 1406  
1397 +
1407 1407  = 10. FCC Caution for RS485LN-US915 =
1408 1408  
1409 1409  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0