From version < 58.38 >
edited by Xiaoling
on 2022/06/06 11:56
To version < 58.25 >
edited by Xiaoling
on 2022/06/06 11:27
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -103,6 +103,7 @@
103 103  * Support Modbus protocol
104 104  * Support Interrupt uplink (Since hardware version v1.2)
105 105  
106 +
106 106  == 1.4 Applications ==
107 107  
108 108  * Smart Buildings & Home Automation
... ... @@ -112,6 +112,7 @@
112 112  * Smart Cities
113 113  * Smart Factory
114 114  
116 +
115 115  == 1.5 Firmware Change log ==
116 116  
117 117  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -305,6 +305,8 @@
305 305  )))
306 306  )))
307 307  
310 +
311 +
308 308  === 3.3.2 Configure sensors ===
309 309  
310 310  (((
... ... @@ -323,6 +323,8 @@
323 323  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
324 324  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
325 325  
330 +
331 +
326 326  === 3.3.3 Configure read commands for each sampling ===
327 327  
328 328  (((
... ... @@ -1178,20 +1178,20 @@
1178 1178  == 3.7 Buttons ==
1179 1179  
1180 1180  
1181 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:400px" %)
1182 -|=(% style="width: 50px;" %)**Button**|=(% style="width: 350px;" %)**Feature**
1183 -|(% style="width:50px" %)**ACT**|(% style="width:350px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1184 -|(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485
1185 -|(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1187 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)
1188 +|=**Button**|=(% style="width: 1420px;" %)**Feature**
1189 +|**ACT**|(% style="width:1420px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1190 +|**RST**|(% style="width:1420px" %)Reboot RS485
1191 +|**PRO**|(% style="width:1420px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1186 1186  
1187 1187  
1194 +
1188 1188  == 3.8 LEDs ==
1189 1189  
1190 -
1191 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1192 -|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature**
1197 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)
1198 +|=**LEDs**|=**Feature**
1193 1193  |**PWR**|Always on if there is power
1194 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1200 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN** (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds**(%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1195 1195  
1196 1196  
1197 1197  
... ... @@ -1218,12 +1218,9 @@
1218 1218  [[image:1654162368066-342.png]]
1219 1219  
1220 1220  
1221 -(((
1222 1222  More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1223 -)))
1224 1224  
1225 1225  
1226 -
1227 1227  == 5.2 Common AT Command Sequence ==
1228 1228  
1229 1229  === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
... ... @@ -1297,23 +1297,13 @@
1297 1297  
1298 1298  == 6.1 How to upgrade the image? ==
1299 1299  
1300 -(((
1301 1301  The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to:
1302 -)))
1303 1303  
1304 -* (((
1305 -Support new features
1306 -)))
1307 -* (((
1308 -For bug fix
1309 -)))
1310 -* (((
1311 -Change LoRaWAN bands.
1312 -)))
1305 +* Support new features
1306 +* For bug fix
1307 +* Change LoRaWAN bands.
1313 1313  
1314 -(((
1315 1315  Below shows the hardware connection for how to upload an image to RS485-LN:
1316 -)))
1317 1317  
1318 1318  [[image:1654162535040-878.png]]
1319 1319  
... ... @@ -1324,10 +1324,8 @@
1324 1324  **Step3: **Open flashloader; choose the correct COM port to update.
1325 1325  
1326 1326  (((
1327 -(((
1328 1328  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1329 1329  )))
1330 -)))
1331 1331  
1332 1332  
1333 1333  [[image:image-20220602175818-12.png]]
... ... @@ -1390,6 +1390,7 @@
1390 1390  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1391 1391  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1392 1392  
1384 +
1393 1393  = 9.Packing Info =
1394 1394  
1395 1395  
... ... @@ -1406,6 +1406,7 @@
1406 1406  * Package Size / pcs : 14.5 x 8 x 5 cm
1407 1407  * Weight / pcs : 170g
1408 1408  
1401 +
1409 1409  = 10. FCC Caution for RS485LN-US915 =
1410 1410  
1411 1411  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0